Search results for " Medical imaging"
showing 10 items of 1067 documents
Editorial 1/2016
2015
It is with great pleasure to wish all our readers, authors and reviewers a happy and healthy new year 2016! Dentomaxillofacial Radiology is fortunate to look back on some rather successful years. Our speciality, that is, oral and maxillofacial (radiological) imaging gained increasing importance over the past decade, which is predominantly a result of the success of CBCT. Lately, we have seen an increasing number of articles (e.g. Petersen Johan Aps Gang Li
Italian inter-society expert panel position on radiological exposure in Neonatal Intensive Care Units.
2020
Abstract Background In the recent years, clinical progress and better medical assistance for pregnant women, together with the introduction of new complex technologies, has improved the survival of preterm infants. However, this result requires frequent radiological investigations mostly represented by thoracic and abdominal radiographs in incubators. This document was elaborated by an expert panel Italian inter-society working group (Radiologists, Paediatricians, Medical Physicists) with the aim to assist healthcare practitioners in taking choices involving radiation exposures of new-born infants and to provide practical recommendations about justification and optimization in Neonatal Inte…
Classification based on Iterative Object Symmetry Transform
2004
The paper shows an application of a new operator named the iterated object transform (IOT) for cell classification. The IOT has the ability to grasp the internal structure of a digital object and this feature can be usefully applied to discriminate structured images. This is the case of cells representing chondrocytes in bone tissue, giarda protozoan, and myeloid leukaemia. A tree classifier allows us to discriminate the three classes with a good accuracy.
Cone-beam computed tomography in lung stereotactic ablative radiation therapy: predictive parameters of early response
2016
To analyze lung lesion volume variations by contouring on cone-beam CT (CBCT) images to evaluate the early predictive parameters of stereotactic ablative radiation therapy (SABR) treatment response.The prescribed dose of SABR was varied according to the tumour site (central or peripheral) and maximum diameter of the lesions by using a strategy of risk-adapted dose prescription with a dose range between 48 and 70 Gy in 3-10 consecutive fractions. For the purpose of the analysis, the gross tumour volume (GTV) was recontoured for each patient at first and last CBCT using two lung levels/windows: (a) -600/1000 HU and (b) -1000/250 HU. Univariate analysis was performed to evaluate a correlation …
9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy
2018
Introduction Recently, cancer treatment improvement enabled an increase in patients’ survival rate. In more than half of the cases, radiotherapy participates in the cure for cancer. The efficacy of this technique is well known but it inevitably delivers doses to normal tissues exposing them to radio-induced complications risks [1] . Moreover, the longer patients’ life expectancy increases the risk of developing long-term complications such as second cancers. Thus, evaluating the risks following cancer treatment involving radiotherapy constitutes a major challenge. In this context, an experimental tool has been developed to evaluate normal tissue doses delivered by the different radiotherapy…
2020
One crucial parameter to evaluate the state of the heart after myocardial infarction (MI) is the viability of the myocardial segment, i.e., if the segment recovers its functionality upon revascularization. MRI performed several minutes after the injection of a contrast agent (delayed enhancement-MRI or DE-MRI) is a method of choice to evaluate the extent of MI, and by extension, to assess viable tissues after an injury. The Emidec dataset is composed of a series of exams with DE-MR images in short axis orientation covering the left ventricle from normal cases or patients with myocardial infarction, with the contouring of the myocardium and diseased areas (if present) from experts in the dom…
On utilizing an enhanced object partitioning scheme to optimize self-organizing lists-on-lists
2020
With the advent of “Big Data” as a field, in and of itself, there are at least three fundamentally new questions that have emerged, namely the Artificially Intelligence (AI)-based algorithms required, the hardware to process the data, and the methods to store and access the data efficiently. This paper (The work of the second author was partially supported by NSERC, the Natural Sciences and Engineering Council of Canada. We are very grateful for the feedback from the anonymous Referees of the original submission. Their input significantly improved the quality of this final version.) presents some novel schemes for the last of the three areas. There have been thousands of papers written rega…
Quantifying brain tumor tissue abundance in HR-MAS spectra using non-negative blind source separation techniques
2012
Given high-resolution magic angle spinning (HR-MAS) spectra from several glial tumor subjects, our goal is to differentiate between tumor tissue types by separating the different sources that contribute to the profile of each spectrum. Blind source separation techniques are applied for obtaining characteristic profiles for necrosis, highly cellular tumor and border tumor tissue and providing the contribution (abundance) of each of these tumor tissue types to the profile of each spectrum. The problem is formulated as a non-negative source separation problem. Non-negative matrix factorization, convex analysis of non-negative sources and non-negative independent component analysis methods are …
Graph cut-based method for segmenting the left ventricle from MRI or echocardiographic images
2017
International audience; In this paper, we present a fast and interactive graph cut method for 3D segmentation of the endocardial wall of the left ventricle (LV) adapted to work on two of the most widely used modalities: magnetic resonance imaging (MRI) and echocardiography. Our method accounts for the fundamentally different nature of both modalities: 3D echocardiographic images have a low contrast, a poor signal-to-noise ratio and frequent signal drop, while MR images are more detailed but also cluttered and contain highly anisotropic voxels. The main characteristic of our method is to work in a 3D Bezier coordinate system instead of the original Euclidean space. This comes with several ad…
Accuracy and Safety of Ultrasound-Guided Core Needle Biopsy of Soft Tissue Tumors in an Outpatient Setting: A Sarcoma Center Analysis of 392 Consecut…
2021
Simple Summary In patients with unclear soft tissue lesions, treatment planning largely depends on histology. Core needle biopsy is the diagnostic standard in these cases. The aim of this retrospective study was to investigate accuracy and safety of ultrasound guided core needle biopsy at a tertiary referral center. We show that ultrasound guided biopsy was feasible as a one stop shop procedure in an outpatient setting in 87.6% of the cases. The rate of conclusive biopsies was 88.5%. After surgical resection, the dignity, tumor type and histopathological grading of the biopsy matched one of the resection specimens in 97.2%, 92.7% and 92.5% of the cases, respectively. Major complications occ…