Search results for " Medical imaging"

showing 10 items of 1067 documents

A low threshold to ECG-gated repeat CTA reduces the risk of false-positive diagnosis of type A dissection in interhospital referrals: a case series s…

2018

Angela Kornberger,1 Iris Burck,2 Hazem El Beyrouti,1 Nancy Halloum,1 Andres Beiras-Fernandez,1 Christian-Friedrich Vahl1 1Department of Cardiothoracic and Vascular Surgery, University Hospital of Johannes Gutenberg University, Mainz, Germany; 2Department of Diagnostic and Interventional Radiology, University Hospital of Johann Wolfgang Goethe University, Frankfurt am Main, Germany Background: False-positive diagnosis of acute Stanford type A aortic dissection (AAD) on computed tomography angiography (CTA) is still an issue and may lead to substantial consequences. Given that electrocardiography (ECG)-gated CTA provides greater diagnostic safety, it may be assumed that interhospital referral…

medicine.medical_specialtyStanford type A dissectionTherapeutics and Clinical Risk Managementfalse-positive diagnosisECG-gated CTA030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicinePharmacology (medical)Case Seriescardiovascular diseasesGeneral Pharmacology Toxicology and PharmaceuticsType a dissectionComputed tomography angiographyAortic dissectionChemical Health and Safetymedicine.diagnostic_testbusiness.industrymusculoskeletal neural and ocular physiologyGeneral Medicinemedicine.diseaseRadiologybusinessSafety ResearchElectrocardiographypsychological phenomena and processesCase seriesTherapeutics and Clinical Risk Management
researchProduct

Stereotactic body radiation therapy for liver oligometastases: predictive factors of local response by 18F-FDG-PET/CT

2018

Objective:To investigate metabolic parameters as predictive of local response after stereotactic body radiation therapy (SBRT) for liver-oligometastases.Methods:Inclusion criteria of the present re...

medicine.medical_specialtyStereotactic body radiation therapybusiness.industryLiver NeoplasmsHumans; Liver Neoplasms; Retrospective Studies; Treatment Outcome; Fluorodeoxyglucose F18; Positron Emission Tomography Computed Tomography; Radiopharmaceuticals; Radiosurgery; Radiology Nuclear Medicine and ImagingGeneral MedicineRadiosurgery030218 nuclear medicine & medical imaging03 medical and health sciencesTreatment Outcome0302 clinical medicineFluorodeoxyglucose F18Positron Emission Tomography Computed TomographyNuclear Medicine and Imaging030220 oncology & carcinogenesisHumansMedicineRadiology Nuclear Medicine and imagingFdg pet ctRadiologyRadiopharmaceuticalsRadiologybusinessRetrospective StudiesThe British Journal of Radiology
researchProduct

Imaging funzionale per diffusione (DWI) e ischemia cerebrale in fase acuta: Potenzialità diagnostiche e confronto con metodiche convenzionali

1997

Stroke is the third leading cause of death and is a major cause of long-term disability. Neuroprotective treatment within a 4-hour «therapeutic window» has proved highly efficacious in reducing morbility and mortality in animal model. It is with this background that the need for emergent diagnosis and therapy of acute stroke in strongly suggested. Computed tomography (CT) shows the parenchymal changes of acute stroke too late to be helpful, and its role has been primarily to evaluate the possibility of intracerebral or subarachnoid hemorrhage. While conventional magnetic resonance (MR) imaging can demonstrate parenchymal abnormalities 4–6 hours after ischemia, newer techniques such as diff…

medicine.medical_specialtySubarachnoid hemorrhageRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryIschemiaInfarctionMagnetic resonance imagingmedicine.diseaseNeuroprotection030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAnimal modelmedicineRadiology Nuclear Medicine and imagingcardiovascular diseasesNeurology (clinical)RadiologybusinessStroke030217 neurology & neurosurgeryCause of deathRivista di Neuroradiologia
researchProduct

2020

Background: Computed tomography angiography (CTA) is frequently used with computed tomography perfusion imaging (CTP) to evaluate whether endovascular vasospasm treatment is indicated for subarachnoid hemorrhage patients with delayed cerebral ischemia. However, objective parameters for CTA evaluation are lacking. In this study, we used an automated, investigator-independent, digital method to detect vasospasm, and we evaluated whether the method could predict the need for subsequent endovascular vasospasm treatment. Methods: We retrospectively reviewed the charts and analyzed imaging data for 40 consecutive patients with subarachnoid hemorrhages. The cerebrovascular trees were digitally rec…

medicine.medical_specialtySubarachnoid hemorrhagemedicine.diagnostic_testReceiver operating characteristicbusiness.industryIschemiaVasospasmmedicine.diseasenervous system diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineCerebral vasospasmNeurologymedicine.arterycardiovascular systemmedicineComputed Tomography Perfusion Imagingcardiovascular diseasesNeurology (clinical)Radiologybusiness030217 neurology & neurosurgeryCircle of WillisComputed tomography angiographyFrontiers in Neurology
researchProduct

Cardiovascular magnetic resonance-derived aortic compliance, distensibility and pulse wave velocity at rest and during a supine bicycle exercise in y…

2014

Background Purpose: Risk of aortic rupture is evaluated based on the vessel diameter; this parameter is probably insufficient. In vivo evaluation of biomechanical property of the aortic tissue might be of interest to discriminate between normal and altered aortic tissue (A Lalande et al, JMRI 2008). The purpose of this study was to describe a technique to measure regional aortic compliance (AC), aortic distensibility (AD) and aortic stiffness with 1.5 T MRI in young individuals under resting conditions and during supine bicycle exercise.

medicine.medical_specialtySupine position[INFO.INFO-IM] Computer Science [cs]/Medical Imaging030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineInternal medicinemedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingRadiology Nuclear Medicine and imagingYoung adultAortic rupturePulse wave velocityComputingMilieux_MISCELLANEOUSAngiologyMedicine(all)Radiological and Ultrasound Technologymedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryMagnetic resonance imagingCompliance (physiology)Poster Presentationcardiovascular systemCardiologyAortic stiffnessCardiology and Cardiovascular Medicinebusiness
researchProduct

Magnetic resonance microscopy and correlative histopathology of the infarcted heart

2019

Altres ajuts:The present study was supported by the EU Joint Programming Initiative 'A Healthy Diet for a Healthy Life' (JPI HDHL INTIMIC-085), Generalitat Valenciana (GV/2018/116), INCLIVA and Universitat de Valencia (program VLC-BIOCLINIC 20-nanomIRM-2016A). Delayed enhancement cardiovascular magnetic resonance (MR) is the gold-standard for non-invasive assessment after myocardial infarction (MI). MR microscopy (MRM) provides a level of detail comparable to the macro objective of light microscopy. We used MRM and correlative histopathology to identify infarct and remote tissue in contrast agent-free multi-sequence MRM in swine MI hearts. One control group (n = 3 swine) and two experimenta…

medicine.medical_specialtySwineMyocardial InfarctionIschemiaCardiologylcsh:MedicineDelayed enhancement030204 cardiovascular system & hematologyArticle030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineAnimalsHumansMyocardial infarctionlcsh:ScienceAcute miMicroscopyMultidisciplinaryintegumentary systemmedicine.diagnostic_testbusiness.industryMagnetic resonance microscopylcsh:RMagnetic resonance imagingDiagnostic markersmedicine.diseaseMagnetic Resonance ImagingDisease Models AnimalInfarcted heartlcsh:QHistopathologyNuclear medicinebusiness
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

GEC-ESTRO ACROP recommendations on calibration and traceability of LE-LDR photon-emitting brachytherapy sources at the hospital level

2019

Prostate brachytherapy treatment using permanent implantation of low-energy (LE) low-dose rate (LDR) sources is successfully and widely applied in Europe. In addition, seeds are used in other tumour sites, such as ophthalmic tumours, implanted temporarily. The calibration issues for LE-LDR photon emitting sources are specific and different from other sources used in brachytherapy. In this report, the BRAPHYQS (BRAchytherapy PHYsics Quality assurance System) working group of GEC-ESTRO, has developed the present recommendations to assure harmonized and high-quality seed calibration in European clinics. There are practical aspects for which a clarification/procedure is needed, including aspect…

medicine.medical_specialtyTraceabilityComputer scienceCalibration (statistics)medicine.medical_treatmentBrachytherapyBrachytherapy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineHumansRadiology Nuclear Medicine and imagingMedical physicsPhotonsbusiness.industryLE-LDRBrachytherapy; LE-LDR; Seeds; CalibrationHospital levelRadiotherapy DosageHematologyHospitalsOncology030220 oncology & carcinogenesisSeedsCalibrationRadiologi och bildbehandlingbusinessQuality assuranceProstate brachytherapyRadiology Nuclear Medicine and Medical Imaging
researchProduct

Posttraumatic chronic cranial osteomyelitis due to a superficial wound - A clinical and neuroradiological case report

2019

Background: Osteomyelitis is a progressive infection of bone and bone marrow by microorganisms, resulting in inflammatory destruction of bone, bone necrosis, and new bone formation. Skull involvement is a rare occurrence which mainly affects children with chronic inflammatory diseases of paranasal sinusitis, or malignant otitis. In adults, cranial vault osteomyelitis can occur after cranial surgery or head trauma. Case Description: We describe an unusual case of chronic cranial osteomyelitis occurred 3 months following a mild traumatic brain injury. The causative mechanisms along with the diagnostic modalities are discussed. Conclusion: Focal cranial vault osteomyelitis, in the absence of …

medicine.medical_specialtyTraumatic brain injuryhead injury complication skull osteomyelitiCase Report030218 nuclear medicine & medical imagingHead trauma03 medical and health sciences0302 clinical medicineCranial vault osteomyelitishead injury complication skull osteomyelitisCranial vaultmedicineMedical historybusiness.industryOsteomyelitisCranial vault osteomyelitimedicine.diseaseCranial vault osteomyelitis head injury complication skull osteomyelitis posttraumatic osteomyelitis posttraumatic skull osteomyelitisposttraumatic osteomyelitisSkullposttraumatic osteomyelitimedicine.anatomical_structureOtitisSurgeryNeurology (clinical)RadiologyBone marrowmedicine.symptomposttraumatic skull osteomyelitisbusiness030217 neurology & neurosurgery
researchProduct

Imaging of inner ear malformations: a primer for radiologists

2021

AbstractIn the multidisciplinary management of patients with inner ear malformations (IEMs), the correct diagnosis makes the differences in terms of clinical and surgical treatment. The complex anatomical landscape of the inner ear, comprising several small structures, makes imaging of this region particularly challenging for general radiologists. Imaging techniques are important for identifying the presence and defining the type of IEM and the cochlear nerve condition. High-resolution magnetic resonance imaging (MRI) sequences and high-resolution computed tomography (HRCT) are the mainstay imaging techniques in this area. Dedicated MRI and HRCT protocols play an important role in the diagn…

medicine.medical_specialtyTreatment outcome030218 nuclear medicine & medical imagingInner ear malformations03 medical and health sciencesComputed Tomography0302 clinical medicineMagnetic resonance imagingMultidetector Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingInner earSurgical treatmentNeuroradiologymedicine.diagnostic_testbusiness.industryCochlear nerveSettore MED/37 - NeuroradiologiaMagnetic resonance imagingInterventional radiologyInner ear malformationGeneral Medicinemedicine.diseaseSensorineural hearing lossmedicine.anatomical_structureEar InnerSensorineural hearing losssense organsRadiologyTomography X-Ray ComputedbusinessSettore MED/36 - Diagnostica Per Immagini E Radioterapia030217 neurology & neurosurgery
researchProduct