Search results for " Misure"
showing 10 items of 421 documents
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
A Phase-Locked Loop for the Synchronization of Power Quality Instruments in the Presence of Stationary and Transient Disturbances
2007
Power quality instrumentation requires accurate fundamental frequency estimation and signal synchronization, even in the presence of both stationary and transient disturbances. In this paper, the authors present a synchronization technique for power quality instruments based on a single-phase software phase-locked loop (PLL), which is able to perform the synchronization, even in the presence of such disturbances. Moreover, PLL is able to detect the occurrence of a transient disturbance. To evaluate if and how the synchronization technique is adversely affected by the application of stationary and transient disturbing influences, appropriate testing conditions have been developed, taking int…
Impact of industrial environments on the PC-based measurements
2007
In the paper we present a simple and fast procedure to evaluate the impact of the electromagnetic disturbances, which can be present in the industrial locations, on the measurements performed by a generic PC-based measurement instrument. The method is conceived starting from the data obtained by subjecting the instruments to the disturbances prescribed by the IEC-61326 standard. The results show that, even under heavy disturbances, the common good practices of shielding and grounding allow a correct employment of this kind of instrumentation.
Smart renewable generation for an islanded system. Technical and economic issues of future scenarios
2012
The subject addressed in this paper is the analytical study of the transition of an energy generation system for a real MV/LV distribution system from one that is “fuel-based” to a distributed and smart “renewables-based” system. The paper outlines both the technical and the economic issues related to such a transition from one type of system to the other. The study is carried out for a real islanded network located in the Island of Pantelleria (Mediterranean Sea). The results obtained are presented and discussed, putting into evidence the technical, environmental and economic benefits of using smart technologies and renewable energy sources.
Introductory notes for the Acta IMEKO Special Issue on the 24th IMEKO Technical Committee 4 International Symposium and the 22nd International Worksh…
2021
Measurement has always been a tool by which we can observe the world around us. This concept was once again confirmed during the 24th IMEKO Technical Committee 4 (TC4) International Symposium, which showed how topics related to the world of measurement range across many fields of knowledge. The IMEKO TC4 International Symposium is one of the most important events in the fields concerned with the theoretical and practical aspects of the measurement of electrical quantities and related instrumentation. It involves institutions and academia in a discussion of the state of the art and issues that require a joint approach by engineers, academics and other experts of measurement, instrumentation,…
Transition of a distribution system towards an active network. Part II: Economical analysis of selected scenario
2011
This paper outlines the economical issues related to the transition of the energy generation for a real MV/LV distribution system from a ‘fuel based’ one to a distributed and smart ‘renewables based’ one. It is the prosecution of a companion paper, which addressed the technical issues connected to such transition. The study has been carried out by University of Palermo and ENEA (Italy), on a portion of real MV/LV distribution system of the research center ENEA of Casaccia (Rome, Italy). The analysis is carried out for a specific scenario chosen among those proposed in the companion paper.
Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid
2015
This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…
Partial discharges on IGBT modules: Are sinusoidal waveforms sufficient to evaluate behavior?
2014
In recent years, the increasing use of AC-DC converters, especially in the field of renewable energy sources has led to the implementation of new modulation techniques, in particular the ones based on the pulse width modulation. The purpose of the present work is to verify the different behavior that is obtained when the components are subjected to the partial discharge test carried out with a sinusoidal waveform, and when they are subjected to PWM stress-type, similar to the actual signal generated by this type of electronic components. By considering equal rms value of the fundamental sine wave, the comparison has shown different partial discharges patterns.
Experimental characterization of series arc faults in AC and DC electrical circuits
2014
This paper presents an experimental characterization of the arc fault phenomenon, for both AC and DC systems, focusing the attention on series arcs. The aim of the study is to find some current characteristics, which can be significant for the purpose of arc detection. The arcing current signal is analyzed in both time and frequency domain. For the AC analysis, the test conditions are chosen in accordance with the “unwanted tripping tests” and the “operation inhibition tests” reported in the Standard UL 1699. The DC study is carried out on the currents waveforms acquired during some on-field tests on a PV plant. Starting from the study herein presented, the authors have found that is it pos…
Narrowband power line communications for medium voltage smart grids
2014
The aim of the paper is to show how narrowband power line communications (NB-PLCs) can be a valid solution for medium voltage grids. Advantages and drawbacks of this solution are analyzed, starting from some experimental communication results, which were carried out on the medium power system networks of the islands of Ustica and Favignana, in the presence of the net voltage. Furthermore, some communication architectures and hardware prototypes based on NB-PLCs are proposed for different smart grids applications.