Testing and linearity calibration of films of phenol compounds exposed to thermal neutron field for EPR dosimetry
2015
This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was fou…
Valutazione della dose neutronica ambientale a livello del suolo
2018
Lo studio e la conoscenza della variabilità della fluenza neutronica di origine cosmica a livello del suolo risulta importante per valutare le misurazioni di dose neutronica ambientale, effettuate sia nell’ambito di molte applicazioni mediche, essenziamente in terapia, sia nelle applicazioni industriali, come nello studio degli effetti delle radiazioni neutroniche sul funzionamento dei più comuni sistemi elettronici. Infatti la sorgente primaria dei neutroni è individuabile nell’interazione tra i raggi cosmici di origine solare ed i vari strati dell’atmosfera e pertanto il campo neutronico non è costante ma dipende fortemente dai cicli di attività solare. In questo lavoro sono presentati i …
Procedura di calibrazione di un set di Dosimetri TLD secondo la ISO/ASTM51956:2005(E) e la ASTM standard E-668
2016
La misura della dose assorbita da dosimetri passivi, a seguito della loro esposizione a radiazioni ionizzanti, è una procedura fondamentale per valutare gli effetti indotti da tali radiazioni nell’ambito della dosimetria ambientale. Per effettuare delle corrette valutazioni, è stato selezionato un set di dosimetri a termoluminescenza (TLD) scelti, tra un’ampia gamma di tipologie di dosimetri a nostra disposizione, come i più idonei a fornire misure di dose attendibili (nelle prescritte condizioni di funzionamento). Tali dosimetri sono stati sottoposti ad una specifica procedura di irraggiamento e successiva lettura, allo scopo di realizzare un’opportuna calibrazione nel rispetto di quanto p…
Dosimetry of Mainz reactors by means of ESR dosimetry with alanine added with gadolinium
2014
Characterization of the ESR response of alanine dosimeters to low-energy (1-40 keV) X-rays
2016
The aminoacid L-a-alanine has attracted considerable interest for use in radiation ESR dosimetry and has been formally accepted as a secondary standard for high-dose (kGy) and transfer dosimetry . The accuracy of the method is quite high, largely due to the low dependence of the alanine response on various irradiation parameters (photon energies above 100 keV, dose rate, temperature, etc.). Furthermore, this system presents alinear response to dose, fairly high sensitivity, tissue equivalence, absence of fading, small dimensions, ruggedn ess, and non-destructive readout. In this work, we examined the energy dependence of alanine ESR dosimeters in the low energy X-photon energy range between…
Valutazioni di efficienza di rivelatori HPGe con il codice MCNP5
2008
Sono presentate alcune simulazioni con il codice MCNP5 di rivelatori di fotoni di tipo HPGe (High Purity Germanium) per la valutazione di efficienze per alcune geometrie usualmente impiegate in misure di tipo radioprotezionistico (Marinelli beakers, a disco, etc). Il modello del rivelatore è validato mediante confronti con determinazioni sperimentali di sorgenti puntiformi calibrate di tipo “single line”, caratterizzate dalla emissione di un solo fotone gamma per disintegrazione. L’ottimizzazione è realizzata valutando in tutto il range energetico di interesse le differenze tra i valori simulati e sperimentali di efficienza, sia fotoelettrica che totale, al variare di alcuni dei parametri c…
EVALUATION OF ENVIRONMENTAL NEUTRON DOSE AT GROUND LEVEL
2021
This work presents the results of two cycles of neutron dose rate measurements realized using an ALNOR 2202D Neutron Dose Rate Meter whose time response is acquired and analyzed through a controlled ORTEC MCS-32 acquisition card in Windows environment. The data obtained have been compared with values from previous experimental surveys and with the data provided by the worldwide main observatories. It has been also verified the influence of the fluctuations in the flux of cosmic rays during the course of a solar cycle. By comparing the realized measurements and the data provided by the cosmic ray monitoring networks it is also possible to obtain a value of ambient dose equivalent rate and ne…
Analysis of 7Be and 210Pb concentration and 7Be/210Pb activity ratio in ground level air in Palermo (Italy).
2019
Recently a renewed interest has been put on the use of radioactive tracers to study transport and mixing processes in the atmosphere. Among the most commonly used radioactive tracers in the atmosphere, 7Be and 210Pb have assumed an ever-increasing importance. Beryllium-7 is the product of the interaction of cosmic rays with Nitrogen and Oxygen nuclei. Its cosmogenic origin makes the measured concentrations strongly dependent on the geographical position and seasonal cycles. It emits 478 keV gamma photons and has a half-life of about 53 days.
Misure di radioattività ambientale a Palermo: analisi statistica delle concentrazioni in aria di 7Be e 210Pb
2016
In questo lavoro sono presi in considerazione gli andamenti delle concentrazioni in aria di 7Be e, per un più limitato periodo di tempo di 210Pb, e si è proceduto ad una analisi statistica dei dati, prendendo in esame le serie temporali (integrandole per i dati mancanti) dei valori medi mensili e settimanali al fine di operare confronti omogenei con dati disponibili di altre zone geografiche. Sono state studiate le correlazioni fra le serie di dati per i due radionuclidi ed è stata effettuata l’analisi in frequenza al fine di evidenziare ciclicità stagionali. Le analisi effettuate mostrano l’importanza dei processi di trasporto in atmosfera e l’influenza dei parametri meteo-climatici (in pa…
Study of optical absorbance and MR relaxation of irradiated Fricke Xylenol Orange Gel Dosimeters
2016
Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measurements pe…