Search results for " Misure"

showing 10 items of 421 documents

Experimental investigation on high-efficiency control algorithms for three-phase induction motors

2020

This paper presents an experimental investigation regarding the power losses variations occurring in three-phase induction motors (IMs) as a function of the magnetization level of the machine. More in detail, the power losses identification is obtained by changing in real-time the working operating conditions of the IM drive and the IM reference flux. The sets of measurements are carried out by setting up a test bench and the obtained results confirm that the power losses occurring in induction motors can be minimized by adequately setting the direct axis current component for each IM working condition. This research represents the starting point for the conception of advanced real-time los…

Settore ING-IND/31 - ElettrotecnicaEfficiencyElectric machine controlInduction motorSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Design and control of an innovative electronic load for the photovoltaic module characterization

2016

The paper proposes a new electronic load setup for a fast, low-cost and standard-compliant characterization of a photovoltaic module. The approach is based on the use of a DC-DC converter, exploiting its ability to emulate a resistor. In particular, a Buck-Boost converter topology is employed. The model is implemented in the Simulink/SimPower System environment. A commercial PV Conergy E215P photovoltaic module is used in order to evaluate the performances of the proposed electronic load and to validate the proposed approach.

Settore ING-IND/31 - ElettrotecnicaPV moduleDC–DC converterDC-DC converterlcsh:Electrical engineering. Electronics. Nuclear engineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettricielectronic loadSettore ING-INF/07 - Misure Elettriche E Elettronichelcsh:TK1-9971PV characterization
researchProduct

Comparison of three control drive systems for interior permanent magnet synchronous motors

2017

In a previous paper, we proposed a control strategy for interior permanent synchronous motors, which takes into account also the reduction of the motor power losses. The novelty of the suggested approach is that it takes into consideration the variations of all the motor parameters that have an influence on its efficiency. In order to verifyon the field the effectiveness of this new method, we implemented the proposed loss model algorithm in a control drive system and compared its performances, in terms of energy losses with respect to other conventional techniques.

Settore ING-IND/31 - ElettrotecnicaSpeed control drive systemsInterior permanent magnet synchronous motorSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciSettore ING-INF/07 - Misure Elettriche E ElettronichePower loss minimization
researchProduct

Performances of rainfall energy harvester

2014

In this paper the performances of rainfall energy harvesting by means of piezoelectric transducers is presented. Diverse studies agree on the level of suitable generated voltage on the electrodes of a piezoelectric transducer subjected to rainfall, but a complete characterization on the supplied power is still missing. This work, in order to limit optimistic forecasts, takes into account the behavior of the transducers subjected to real and also artificial rainfall, condition that has shown promising behavior in laboratory. In order to increase the energy harvesting and also define its limits different loads have been taken into account. Only commercial transducers have been considered: a l…

Settore ING-IND/31 - Elettrotecnicaharvester piezoelectricSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A New Protection Strategy for Electrical Distribution Systems

2010

In this paper, the authors propose a new protection strategy for electrical Medium Voltage distribution networks, based on a distributed intelligence system composed of a central unit and of many local processing units. The distributed intelligence system can precisely identify and locate faults in suitably limited times. Each local processing unit is composed of a data acquisition system and a data analysis system. The first allows the accurate reconstruction of the fundamental using only 1.5 cycles of under fault transient electrical quantities. The second performs suitably precise on-line fault diagnosis based on the data provided by the data acquisition module. The data acquisition algo…

Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaPower Distribution Protection Power System Faults Fault Diagnosis Fault Location Fundamental ExtractionSettore ING-IND/31 - ElettrotecnicaSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Confronto teorico e sperimentale degli indici di distorsione armonica ed interarmonica: applicazione ad un impianto di generazione fotovoltaico

2005

Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorsione armonica impianto fotovoltaico
researchProduct

Alimentazione della Tunnel Boring Machine “Barbara”: qualità della tensione e mitigazione dei disturbi

2017

Studio attraverso simulazioni supportate da verifiche sperimentali dell’impatto sulla rete della operatività della Tunnel Boring Machine (TBM) utilizzata per lo scavo della nuova galleria inserita all’in- terno dell’itinerario Agrigento-Caltanissetta-A19.

Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaTunnel boring machine power qualitySettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Realizzazione di un campione di potenza tramite una scheda di acquisizione dati commerciale

2010

Settore ING-INF/07 - Misure Elettriche E ElettronicheCampioni di potenza schede di acquisizione dati
researchProduct

ARC FAULT DETECTION EQUIPMENT AND METHOD USING LOW FREQUENCY HARMONIC CURRENT ANALYSIS

2012

An arc fault detection circuit includes a current sensing circuit coupled to a line conductor carrying a current. The current sensing circuit operates to sense current and output data indicative of the sensed current. A processing circuit implements a frequency transform algorithm to transform the output data to frequency data in a low frequency range and with a high spectral resolution where a minimum short time observation window is concerned. The processing circuit identifies an arc fault condition on the line conductor by identifying differences in said frequency data between at least two subsequent observation windows and identifying characteristics which exceed thresholds.

Settore ING-INF/07 - Misure Elettriche E Elettronichearc faults detection home protection photovoltaic systems electrical safety series arcs arc fault circuit interrupter (AFCI) harmonic analysis chirp-z transform (CZT)
researchProduct

A single-point approach based on IEEE 1459-2000 for the identification of prevailing harmonic sources detection in distorted three phase power systems

2009

This paper deals with a novel single-point strategy for the detection of prevailing harmonic sources downstream or upstream the metering section in three-phase power systems. It is an enhancement of a previous strategy, already developed by the authors and it is based on the comparison of three non-active power quantities which are based on the IEEE Std. 1459-2000 approach. The method does not require any spectral analysis of voltages and currents because it is based only on the separation of the fundamental components from the harmonic content of voltage and current. In the paper, the effectiveness of the strategy is investigated by means of simulation tests which were carried out on a IEE…

Settore ING-INF/07 - Misure Elettriche E Elettronichepower measurements harmonic distortion reactive power power quality IEEE Std 1459
researchProduct