Search results for " Misure"
showing 10 items of 421 documents
Characterization of IP-Based Communication for Smart Grid Using Software-Defined Networking
2018
The smart grid (SG) approach is based on a strong interaction between the network communication infrastructure and the power grid. Usually the management of the infrastructure is done by the distribution system operators (DSOs) that are worried about the increasing managing complexity due to the presence of increasing number of distributed energy resources and electrical vehicles. The use of software-defined networking (SDN) may simplify the network configuration and management for DSO, as highlighted from previous research works. The objective of this paper is to introduce and characterize an internet protocol (IP)-based communication architecture with specialized SDN bridges operating als…
Cabine secondarie: nodi intelligenti e sicuri delle smart grid
2015
Nel futuro panorama delle Smart Grid, le cabine secondarie assumeranno il ruolo di nodi intelligenti e sicuri della rete di distribuzione, integrando diverse soluzioni innovative di monitoraggio, comunicazione, controllo e richiedendo maggiori caratteristiche di sicurezza come proposto nei due progetti di ricerca REIPERSEI e NewCabElarc
Studio e sviluppo di innovativi sistemi di misura e di comunicazione per le smart grid
A PC-based instrument for automatic monitoring and control of a CPVT power plant
2014
A PC-based instrument has been developed for the monitoring and control of a concentrated photovoltaic and thermal (CPVT) power plant. The instrument allows acquiring both electrical and thermal quantities. Moreover it implements the solar tracking algorithm used to optimize the power production.
Sistemi di comunicazione e dispositivi di interfaccia per l'integrazione della generazione distribuita nelle smart grids
2014
L'integrazione della generazione distribuita (GD) nelle reti elettriche di distribuzione a media e bassa tensione uno degli elementi chiave per il pieno sfruttamento delle fonti energetiche rinnovabili (FER). Ci implica un ripensamento della gestione e del controllo delle reti elettriche , che devono passare da sistemi " passivi ", con flussi di potenza unidirezionali e un numero limitato di funzioni di monitoraggio e automazione, a reti attive e intelligenti (Òsmart gridsÒ). In tali sistemi, i flussi di potenza possono essere bi-direzionali e, se non correttamente gestiti, possono causare situazioni critiche, quali ad es. problemi di stabilit e di controllo della rete o funzionamento i…
PQ and Harmonic Assessment Issues on Low-Cost Smart Metering Platforms: A Case Study
2020
This paper presents a feasibility study on how to implement power quality (PQ) metrics in a low-cost smart metering platform. The study is aimed at verifying the possibility of implementing PQ monitoring in distribution networks without replacing existing smart metering devices or adding new modules for PQ measurements, thus zeroing the installation costs. To this aim, an electronic board, currently used for remote energy metering, was chosen as a case study, specifically the STCOMET platform. Starting from the specifications of this device, the possibility of implementing power quality metrics is investigated in order to verify if compliance with standard requirements for PQ instruments ca…
Impact of non-programmable distributed generation in an islanded microgrid: the case study of Ustica
2022
The paper presents a systematic analysis of nonprogrammable distributed generation impact in an islanded microgrid Different issues have been analyzed, with a special focus on the most significant ones in a small islanded network. To this aim, the case study of Ustica island was considered A digital twin of the MV network was developed starting from the network topology data and the power measurement acquired in each secondary substation. Simulations were then performed in the hypothesis of a large increment of distributed generation installation into the network. A discussion is then reported on which are the main technical issues to be faced in the considered case study.
A modular neutron irradiator based on 241Am-Be neutron sources
2010
Neutron irradiator facilities with 241Am-Be sources are worldwide used in order to perform neutron activation analysis (NAA), to investigate materials in different research areas or to test and calibrate neutron detectors and environmental or personal dosemeters. The use of a neutron irradiator is advantageous because of its very stable neutron flux, even it is many orders of magnitude lower than the one of a nuclear reactor or a particle accelerator. Most of irradiators are realized with neutron sources located at fixed positions and accordingly the characteristics of neutron spectrum previously assessed do not change. Therefore, an interesting choice is to have a modular facility, capable…
Passive safety systems in view of sustainable development
2010
Compensation of Nonlinearity of Voltage and Current Instrument Transformers
2019
This paper aims at characterizing and improving the metrological performances of current and voltage instrument transformers (CTs and VTs) in harmonic measurements in the power system. A theoretical analysis is carried out to demonstrate that, due to the iron core nonlinearity, CT and VT output signal is distorted even when the input signal is a pure sine wave. Starting from this analysis, a new method for CT and VT characterization and compensation is proposed. In a first step, they are characterized in sinusoidal conditions and the harmonic phasors of the distorted output are measured; in the second step, these phasors are used to compensate the harmonic phasors measured in normal operati…