Search results for " Monitoring"

showing 10 items of 3129 documents

Ten physiological commandments for severe head injury

2020

Advances in multiparametric brain monitoring have allowed us to deepen our knowledge of the physiopathology of head injury and how it can be treated using the therapies available today. It is essential to understand and interpret a series of basic physiological and physiopathological principles that, on the one hand, provide an adequate metabolic environment to prevent worsening of the primary brain injury and favour its recovery, and on the other hand, allow therapeutic resources to be individually adapted to the specific needs of the patient. Based on these notions, this article presents a decalogue of the physiological objectives to be achieved in brain injury, together with a series of …

medicine.medical_specialtySevere head injuryIntracranial Pressurebusiness.industryHead injuryArterial oxygenBrainCerebral hypoxia030208 emergency & critical care medicineGeneral MedicineBrain monitoringmedicine.diseaseNeuroprotectionAbdominal pressureOxygen03 medical and health sciences0302 clinical medicineBrain InjuriesmedicineHumansHypoxia BrainIntensive care medicinebusiness030217 neurology & neurosurgeryIntracranial pressureRevista Española de Anestesiología y Reanimación (English Edition)
researchProduct

Autofluorescence imaging for recurrence detection in skin cancer postoperative scars

2020

This clinical study is a first attempt to use autofluorescence for recurrence diagnosis of skin cancer in postoperative scars. The proposed diagnostic parameter is based on a reduction in scar autofluorescence, evaluated in the green spectral channel. The validity of the method has been tested on 110 postoperative scars from 56 patients suspected of non-melanoma skin cancer, with eight patients (13 scars) available for the repeated examination. The recurrence diagnosis within a scar has been made after two subsequent autofluorescence check-ups, representing the temporal difference between the scar autofluorescence amplitudes as a vector. The recognition of recurrence has been discussed to r…

medicine.medical_specialtySkin NeoplasmsGeneral Physics and AstronomyScarsVector angle01 natural sciencesGeneral Biochemistry Genetics and Molecular Biology010309 opticsClinical studyCicatrix0103 physical sciencesmedicineHumansGeneral Materials SciencePostoperative scarsPostoperative monitoringStage (cooking)business.industryOptical Imaging010401 analytical chemistryGeneral EngineeringGeneral Chemistrymedicine.disease0104 chemical sciencesAutofluorescenceRadiologySkin cancermedicine.symptombusinessJournal of Biophotonics
researchProduct

European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the second international consensus conference …

2008

This document summarizes the available evidence and provides recommendations on the use of home blood pressure monitoring in clinical practice and in research. It updates the previous recommendations on the same topic issued in year 2000. The main topics addressed include the methodology of home blood pressure monitoring, its diagnostic and therapeutic thresholds, its clinical applications in hypertension, with specific reference to special populations, and its applications in research. The final section deals with the problems related to the implementation of these recommendations in clinical practice. ispartof: Journal of Hypertension vol:26 issue:8 pages:1505-1530 ispartof: location:Neth…

medicine.medical_specialtySpecial populationsPhysiologybusiness.industryMEDLINEConsensus conferenceMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREBlood Pressure Monitoring Ambulatoryguidelinesarterial hypertension cardiovascular risk home blood pressure monitoringClinical PracticeEuropeHypertensionInternal MedicinemedicineHumansBlood pressure monitoringHypertension diagnosisDrug MonitoringCardiology and Cardiovascular MedicineIntensive care medicinebusinessAntihypertensive Agents
researchProduct

Problem solving in psychopharmacotherapy using pharmacokinetic and pharmacogenetic tests

2007

Many problems such as non-response, pharmacokinetic interactions with clinical consequences and adverse effects (pharmacovigilance) may be observed in patients submitted to psychopharmacotherapy. These risks are increased in patients belonging to the category of “special populations”: elderly patients, children and adolescents, patients with a genetic particularity of metabolism or suffering from somatic or psychic comorbidities. Pharmacokinetic and pharmacogenetic tests are useful to solve problems in psychopharmacotherapy and thus improve efficacy and safety. Therapeutic drug monitoring (TDM) is particularly recommended in situations presented above and in patients who are non-compliant. …

medicine.medical_specialtySpecial populationsmedicine.diagnostic_testbusiness.industryTreatment outcomePsychiatry and Mental healthPharmacokineticsTherapeutic drug monitoringPharmacovigilancemedicineIn patientIntensive care medicinebusinessAdverse effectPharmacogeneticsEuropean Psychiatry
researchProduct

Recommendations for the clinical use of somatosensory-evoked potentials

2008

The International Federation of Clinical Neurophysiology (IFCN) is in the process of updating its Recommendations for clinical practice published in 1999. These new recommendations dedicated to somatosensory-evoked potentials (SEPs) update the methodological aspects and general clinical applications of standard SEPs, and introduce new sections dedicated to the anatomical-functional organization of the somatosensory system and to special clinical applications, such as intraoperative monitoring, recordings in the intensive care unit, pain-related evoked potentials, and trigeminal and pudendal SEPs. Standard SEPs have gained an established role in the health system, and the special clinical ap…

medicine.medical_specialtySpinothalamic TractsHealth Planning GuidelinesLaser-Evoked Potentialsintraoperative monitoringMEDLINEcomaElectroencephalographysomatosensory-evoked potentialsClinical neurophysiologyEvoked Potentials SomatosensoryPhysiology (medical)Intensive carelaser-evoked potentialsHumansMedicinepainMedical physicspain-evoked potentialsEvoked potentialcns disease; coma; intensive care; intraoperative monitoring; laser-evoked potentials; pain; pain-evoked potentials; pudendal-evoked potentials; recommendations; somatosensory-evoked potentials; trigeminal-evoked potentialsintensive carecns diseasemedicine.diagnostic_testbusiness.industrytrigeminal-evoked potentialsElectroencephalographyNeurophysiologyElectric StimulationSensory Systemspudendal-evoked potentialsNeurologySomatosensory evoked potentialrecommendationsNeurology (clinical)Nervous System DiseasesbusinessNeuroscienceClinical Neurophysiology
researchProduct

Hemodynamic Monitoring in Patients With Subarachnoid Hemorrhage: A Systematic Review and Meta-Analysis

2020

Aneurysmal subarachnoid hemorrhage (aSAH) often causes cardiopulmonary dysfunction. Therapeutic strategies can be guided by standard (invasive arterial/central venous pressure measurements, fluid balance assessment), and/or advanced (pulse index continuous cardiac output, pulse dye densitometry, pulmonary artery catheterization) hemodynamic monitoring. We conducted a systematic review and meta-analysis of the literature to determine whether standard compared with advanced hemodynamic monitoring can improve patient management and clinical outcomes after aSAH. A literature search was performed for articles published between January 1, 2000 and January 1, 2019. Studies involving aSAH patients …

medicine.medical_specialtySubarachnoid hemorrhageCentral Venous PressureHemodynamicslaw.inventionBrain Ischemia03 medical and health sciences0302 clinical medicineRandomized controlled trial030202 anesthesiologylawhemodynamicInternal medicinemedicineHumansCardiac Outputbusiness.industryHemodynamic MonitoringCentral venous pressureSubarachnoid Hemorrhagemedicine.diseaseIntensive care unitConfidence intervalmonitoringAnesthesiology and Pain Medicineblood volumeRelative riskMeta-analysisCardiologySurgeryNeurology (clinical)aneurysmal subarachnoid hemorrhagebusiness030217 neurology & neurosurgery
researchProduct

Arrhythmieprofil und Herzfrequenz bei Hyperthyreose

2008

Arrhythmia profiles and heart rates, obtained by 24-hour ECG monitoring, were analysed in 48 patients with hyperthyroidism before (T3 level: 331 +/- 108 ng/100 ml, heart rate: 95 +/- 13/min), during (T3 level: 202 +/- 98 ng/100 ml, heart rate: 85 +/- 11/min) and after (T3 level: 149 +/- 41 ng/100 ml, heart rate: 79 +/- 9/min) antithyroid treatment. 50 persons in whom organic heart disease has been excluded by invasive and noninvasive tests served as controls. Only 6% of patients had repetitive ventricular arrhythmias (Lown group IV) before treatment (controls: 4%; P greater than 0.05). Supraventricular extrasystoles were common both before and after treatment (P less than 0.001), especially…

medicine.medical_specialtySupraventricular arrhythmiaOrganic heart diseasebusiness.industryIncidence (epidemiology)General MedicineEcg monitoringInternal medicineHeart ratecardiovascular systemmedicineCardiologycardiovascular diseasesbusinessAfter treatmentDMW - Deutsche Medizinische Wochenschrift
researchProduct

Transmission of arterial oxygen partial pressure oscillations to the cerebral microcirculation in a porcine model of acute lung injury caused by cycl…

2013

Cyclic recruitment and derecruitment (R/D) play a key role in the pathomechanism of acute lung injury (ALI) leading to respiration-dependent oscillations of arterial partial pressure of oxygen (Pa(O(2))). These Pa(O(2)) oscillations could also be forwarded to the cerebral microcirculation.In 12 pigs, partial pressure of oxygen was measured in the thoracic aorta (Pa(O(2))) and subcortical cerebral tissue (Pbr(O(2))). Cerebral cortical haemoglobin oxygen saturation (Sbr(O(2))), cerebral blood flow (CBF), and peripheral haemoglobin saturation (Sp(O(2))) were assessed by spectroscopy and laser Doppler flowmetry. Measurements at different fractions of inspired oxygen (F(I(O(2)))) were performed …

medicine.medical_specialtySwineAcute Lung Injurychemistry.chemical_elementBlood PressureLung injuryAnesthesia GeneralOxygenMicrocirculationInternal medicinemedicineLaser-Doppler FlowmetryAnimalsLungOxygen saturation (medicine)Ventilators Mechanicalbusiness.industryMicrocirculationHemodynamicsLaser Doppler velocimetryRespiration Artificialrespiratory tract diseasesOxygenOxygen Saturation MeasurementAnesthesiology and Pain MedicineBlood pressurechemistryCerebral blood flowAnesthesiaCerebrovascular CirculationCardiologybusinessBlood Gas Monitoring TranscutaneousBronchoalveolar Lavage FluidCraniotomyBritish journal of anaesthesia
researchProduct

Sympathetic Overactivity and 24-Hour Blood Pressure Pattern in Hypertensives with Chronic Renal Failure

1995

In order to assess the activity of the sympathetic system and to evaluate the 24-h blood pressure pattern in hypertensives with chronic renal failure (CRF), 12 CRF patients and 16 essential hypertensives (EHs) were studied. In all subjects, plasma samples for catecholamines and renin activity were obtained both in the basal condition and after standing, and 24-h blood pressure monitoring (ABPM) was performed. The 24-h mean blood pressure results were quite similar between CRFs and EHs. In 50% of the CRFs, ABPM showed a nighttime decrease in diastolic BP (DBP) greater than 10%, while in the remaining 50% the ABPM indicated a nondipper blood pressure pattern. Of the 16 EHs, 4 had a nighttime …

medicine.medical_specialtySympathetic nervous systemSympathetic Nervous SystemEpinephrineDiastoleBlood PressureCritical Care and Intensive Care MedicinePlasma renin activityNorepinephrineBasal (phylogenetics)CatecholaminesInternal medicineBlood plasmaHumansMedicinebusiness.industryGeneral MedicineBlood Pressure Monitoring AmbulatoryCircadian RhythmMean blood pressureBlood pressuremedicine.anatomical_structureEndocrinologyNephrologyHypertensionCatecholamineKidney Failure Chronicbusinessmedicine.drugRenal Failure
researchProduct

Radiation exposure in vascular angiographic procedures.

2012

Abstract Purpose To evaluate dose reduction in vascular angiographic procedures by using fluoroscopy capture instead of digital subtraction angiography frames for documentation. Materials and Methods A total of 764 consecutive vascular interventional procedures performed over a period of 1 year were retrospectively analyzed with respect to the fluoroscopy time and the resulting dose–area product (DAP), the DAP of the radiographic frames, and the overall DAP. Results A total of 70% of the total DAP was a result of the acquisition of radiographic frames, leaving only 30% being applied by fluoroscopy. Conclusions Fluoroscopy capture should be used for documentation whenever possible. A registr…

medicine.medical_specialtyTime FactorsRadiographyHealth PersonnelRadiation DosageRadiography InterventionalRadiation ProtectionRadiation MonitoringOccupational ExposuremedicineFluoroscopyHumansRadiology Nuclear Medicine and imagingOccupational HealthRetrospective Studiesmedicine.diagnostic_testbusiness.industryAngiography Digital SubtractionDigital subtraction angiographyRadiation exposureDose area productFluoroscopyDose reductionRadiologyCardiology and Cardiovascular MedicinebusinessNuclear medicineJournal of vascular and interventional radiology : JVIR
researchProduct