Search results for " OPT"

showing 10 items of 13620 documents

Trap-limited mobility in space-charge limited current in organic layers

2009

Space-charge limited current transport in organic devices, relevant to the operation of a range of organic optoelectronic devices, is analyzed in the frequency domain. The classical multiple trapping picture with one transport state and one trap level is used as the basis for the descriptions. By varying the energetic and kinetic properties of the traps, we show that the admittance and the capacitance spectra are considerably modified depending on the interplay between the trap-limited mobility and the trap kinetics. We point out that capacitance steps at low-frequency, usually found in experiments, are observed only for slow traps. © 2008 Elsevier B.V. All rights reserved.

AdmittanceCapacitanceTrappingCapacitanceBiomaterialsTrap (computing)OpticsMaterials ChemistryOLEDPhysics::Atomic PhysicsElectrical and Electronic EngineeringElectrical impedanceMobilityCondensed Matter::Quantum GasesOrganic electronicsChemistrybusiness.industryImpedanceGeneral ChemistryCondensed Matter PhysicsSpace chargeTrapElectronic Optical and Magnetic MaterialsOLEDChemical physicsTransport in organic materialsbusinessOrganic Electronics
researchProduct

Specific separation and recovery of phosphate anions by a novel NiFe-LDH/rGO hybrid film based on electroactivity-variable valence

2022

Phosphorus is a non-renewable resource. Supplies are limited and much phosphorus is currently wasted during the production and utilization process, causing concerns about future supplies and widespread environmental problems. To solve these problems, a new type of NiFe-LDH/rGO electrically switched ion-selective (ESIX) film is designed, based on the dominant mechanism of inner-sphere complexation. An ESIX process allows the NiFe-LDH/rGO hybrid film to achieve a controllably selective uptake and release of the phosphate anions. This route involves tuning potential steps to regulate the redox states of the composite film and the variable metal (e.g., Ni, Fe (II)/(III)) in coordination centers…

Adsorption capacityPhosphorusInner-sphere complexationSettore ING-IND/27 - Chimica Industriale E TecnologicaPhosphatesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsBiomaterialsColloid and Surface ChemistryValence state transitionSelective extractionMetalsLayered double hydroxideHydroxidesGraphitePhosphate anion
researchProduct

Oxidative Stress and Microvascular Alterations in Diabetic Retinopathy: Future Therapies

2019

Diabetes is a disease that can be treated with oral antidiabetic agents and/or insulin. However, patients’ metabolic control is inadequate in a high percentage of them and a major cause of chronic diseases like diabetic retinopathy. Approximately 15% of patients have some degree of diabetic retinopathy when diabetes is first diagnosed, and most will have developed this microvascular complication after 20 years. Early diagnosis of the disease is the best tool to prevent or delay vision loss and reduce the involved costs. However, diabetic retinopathy is an asymptomatic disease and its development to advanced stages reduces the effectiveness of treatments. Today, the recommended treatment for…

Adult0301 basic medicineAgingmedicine.medical_specialtymedicine.medical_treatmentReview ArticleDiseasemedicine.disease_causeBiochemistryAsymptomaticDiabetic Eye DiseaseYoung Adult03 medical and health sciences0302 clinical medicineRisk FactorsInternal medicineDiabetes mellitusmedicineHumanslcsh:QH573-671AgedDiabetic Retinopathybusiness.industrylcsh:CytologyInsulinCell BiologyGeneral MedicineDiabetic retinopathyMiddle Agedmedicine.diseaseOxidative Stress030104 developmental biologyMetabolic control analysis030221 ophthalmology & optometrymedicine.symptombusinessOxidative stressOxidative Medicine and Cellular Longevity
researchProduct

Amplitude, Latency, and Peak Velocity in Accommodation and Disaccommodation Dynamics

2017

The aim of this work was to ascertain whether there are differences in amplitude, latency, and peak velocity of accommodation and disaccommodation responses when different analysis strategies are used to compute them, such as fitting different functions to the responses or for smoothing them prior to computing the parameters. Accommodation and disaccommodation responses from four subjects to pulse changes in demand were recorded by means of aberrometry. Three different strategies were followed to analyze such responses: fitting an exponential function to the experimental data; fitting a Boltzmann sigmoid function to the data; and smoothing the data. Amplitude, latency, and peak velocity of …

AdultArticle Subjectlcsh:MedicineEyeRefraction Ocular050105 experimental psychologyGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineReaction TimeHumans0501 psychology and cognitive sciencesLatency (engineering)MathematicsGeneral Immunology and MicrobiologyPulse (signal processing)business.industrylcsh:R05 social sciencesMathematical analysisWork (physics)Accommodation OcularGeneral MedicineSigmoid functionExponential functionAmplitude030221 ophthalmology & optometrybusinessAccommodationSmoothingResearch ArticleBioMed Research International
researchProduct

Myopia, the challenge of Ophthalmology and its worldwide “explosive epidemic”

2018

AdultAtropinePediatricsmedicine.medical_specialtyAdolescentExplosive materialContact LensesMEDLINE02 engineering and technology01 natural sciences010309 optics020210 optoelectronics & photonicsRisk Factors0103 physical sciencesMyopia0202 electrical engineering electronic engineering information engineeringmedicineHumansAge of OnsetChildLife StyleLightingLife stylebusiness.industryIncidenceIncidence (epidemiology)Disease progressionGeneral MedicineEyeglassesOphthalmic solutionsDisease ProgressionSunlightMorbidityOphthalmic SolutionsAge of onsetbusinessArchivos de la Sociedad Española de Oftalmología (English Edition)
researchProduct

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

2019

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

AdultBiometryMaterials sciencegenetic structuresContact LensesTomography optical coherenceStatistics Nonparametriclaw.invention03 medical and health sciences0302 clinical medicineOpticslcsh:OphthalmologyOptical coherence tomographyLens thicknessAnterior Eye SegmentReference ValueslawmedicineHumansContact lensesAnalysis of VarianceCross-Over Studiesmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineAxial lengtheye diseasesContact lensLens (optics)Axial Length EyeOphthalmologylcsh:RE1-994Reference values030221 ophthalmology & optometrysense organsTomographybusinessTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

The Randomized Shortened Dental Arch Study

2012

The scientific evidence concerning prosthodontic care for the shortened dental arch (SDA) is sparse. This randomized multicenter study aimed to compare two common treatment options: removable partial dental prostheses (RPDPs) for molar replacement vs. no replacement (SDA). One of the hypotheses was that the follow-up treatment differs between patients with RPDPs and patients with SDAs during the 5-year follow-up period. Two hundred and fifteen patients with complete molar loss in one jaw were included in the study. Molars were either replaced by RPDPs or not replaced according to the SDA concept. A mean number of 4.2 (RPDP) and 2.8 (SDA) treatments for biological or technical reasons occur…

AdultChange over timeMolarmedicine.medical_treatmentDentistryDental Abutmentslaw.inventionTooth LossDental ArchRandomized controlled triallawmedicineDenture Precision AttachmentHumansBicuspidProspective StudiesDenture DesignGeneral DentistryObservation timebusiness.industryJaw Edentulous PartiallyTreatment optionsDenture RetentionMolarDental archTreatment Outcomemedicine.anatomical_structureMulticenter studyDenture Partial RemovableProsthodonticsbusinessFollow-Up StudiesJournal of Dental Research
researchProduct

Spontaneous Resolution of Delayed Suprachoroidal Hemorrhage in the Single Eye Following Needling in Congenital Glaucoma

2017

Suprachoroidal hemorrhage (SCH) is a rare, but potentially vision-threatening event with poor long-term visual prognosis. At present, there is disagreement whether surgical intervention or conservative treatment is superior in the management. We report on a case of spontaneous resolution of severe SCH after needling procedure in the only eye of a young patient with congenital glaucoma.A 43-year-old woman with congenital glaucoma was scheduled for bleb needling in her only eye. Preoperative best-corrected visual acuity was 20/40 and intraocular pressure 20 mm Hg. On the third postoperative day, she developed a massive delayed SCH with appositional (kissing) choroidal bullae and visual acuity…

AdultChoroid Hemorrhagemedicine.medical_specialtyCongenital glaucomagenetic structuresRemission SpontaneousVisual AcuityGlaucomaSuprachoroidal hemorrhagePostoperative Hemorrhage03 medical and health sciences0302 clinical medicineOphthalmologyHumansMedicineIntraocular PressureDry needlingbusiness.industryGlaucomamedicine.diseaseConservative treatmentOphthalmology030221 ophthalmology & optometryDrainageFemalebusinessSclera030217 neurology & neurosurgeryJournal of Glaucoma
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct