Search results for " Orthopedic"

showing 10 items of 325 documents

Digital acrometastasis revealing endometrial cancer relapse

2012

Oncology030222 orthopedicsmedicine.medical_specialtybusiness.industryEndometrial cancerImmunologymedicine.disease03 medical and health sciences0302 clinical medicineRheumatology030220 oncology & carcinogenesisInternal medicinemedicineImmunology and AllergyPharmacology (medical)businessArthritis & Rheumatism
researchProduct

Retrospective Data Analysis of Anterior Cervical Discectomies and Fusion Without Plate and Screws

2019

Abstract Surgical intervention in cervical disease can relieve neurological symptoms and improve life quality. This study aimed to analyse retrospective data of microscope-assisted anterior cervical discectomy and fusion (ACDF) surgeries. The retrospective study was carried out at the ORTO clinic, Rīga, Latvia, from 2013 to 2017. Data from 198 patients were extracted retrospectively. Data on patient gender, age, diagnosis, extent of operation, type of cage and the overall height of the implants were used. Comparative analysis was carried out with the SPSS 22 software. P < 0.05 represented statistical significance. During the study period, 198 elective ACDF were carried out with increasin…

Orthodontics030222 orthopedics03 medical and health sciences0302 clinical medicineMultidisciplinaryGeneral interestScienceanterior cervical discectomyQcervical cages030217 neurology & neurosurgeryRetrospective dataProceedings of the Latvian Academy of Sciences. Section B, Natural Sciences
researchProduct

2016

Purpose The use of new headless compression screws (HCSs) for scaphoid fixation is growing, but the nonunion rate has remained constant. The aim of this study was to compare the stability of fixation resulting from four modern HCSs using a simulated fracture model to determine the optimal screw design(s). Methods We tested 40 fresh-frozen cadaver scaphoids treated with the Acumed Acutrak 2 mini (AA), the KLS Martin HBS2 midi (MH), the Stryker TwinFix (ST) and the Synthes HCS 3.0 with a long thread (SH). The bones with simulated fractures and implanted screws were loaded uniaxially into flexion for 2000 cycles with a constant bending moment of 800 Nmm. The angulation of the fracture fragment…

Orthodontics030222 orthopedicsmedicine.medical_specialtyMultidisciplinaryBone densityChemistryNonunionBone fractureWristmedicine.diseaseSurgery03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureScaphoid boneCadaverFracture fixationLinear regressionmedicine030212 general & internal medicinePLOS ONE
researchProduct

Surgical time for graft preparation using different suture techniques

2016

Background: The purpose of the present study was to compare the operative time for graft prepa- ration using different techniques for graft sutur- ing. Material and methods: Flexor profundus tendons were harvested from fresh pig hind-leg trotters. Three different suture techniques were investigat- ed: the Krackow stitch (K), the Whipstitch (W), and the Modified Finger-Trap suture (MFT). Ten- dons were sutured starting at 10 mm from the dis- tal free end of the tendon. The suture configura- tions of the Krackow stitch and Whipstitch were completed with five suture throws. According to the MFT technique, the suture was wrapped five times around the tendon over a distance of 30 mm. The time re…

OrthodonticsSuturing techniques030222 orthopedicsmedicine.medical_specialtybusiness.industrymodified finger-trap suture time consuming krakow stitch whipstitchInterobserver reproducibilitySurgeryTendon03 medical and health sciencesSurgical time0302 clinical medicinemedicine.anatomical_structureSuture (anatomy)Settore MED/33 - Malattie Apparato LocomotoreMedicineOperative timeOriginal ArticleOrthopedics and Sports Medicine030212 general & internal medicinebusinessMuscle Ligaments and Tendons Journal
researchProduct

Surgical Treatment on Subungual Osteochondromas in Paediatric Feet: A Case Series Study

2020

Subungual osteochondroma (SO) is an infrequent and non-malignant bone tumour of the distal phalanx, especially prominent in paediatric populations. The aim of this research was to describe a case series of paediatric feet with SO which received surgical treatments. The secondary purpose was to compare these descriptive data by sex distribution. Methods: Twenty-three paediatric feet with SO confirmed by clinical or radiological features received surgical treatment. Socio-demographic (age, sex, height, weight and BMI) and clinical features (side, location, tumour or pain presence, and nail lift before surgery, as well as recurrence and adverse effects at one month after intervention) were rep…

Osteochondromamedicine.medical_specialtyQuistesbone tumourlcsh:MedicineFisiología humanaArticlelaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled trialchildrenlawmedicine030212 general & internal medicineOssos MalaltiesSistema musculoesqueléticoHuesosSurgical treatmentAdverse effectChildrenPaediatric foot030222 orthopedicsbusiness.industrySubungual osteochondromaPediatríalcsh:RTumors en els infantsGeneral MedicinePhalanxmedicine.diseasepaediatric footSurgeryExtremitatsPodologíasubungual osteochondromaBone tumourRadiological weaponRight lower limbbusinessCase series
researchProduct

Multicentric, multifocal, and recurrent osteoid osteoma of the hip: first case report.

2019

Abstract Background Osteoid osteoma is a benign bone-forming tumour, which very unfrequently has multifocal or multicentric presentation. We report the first known case of a multicentric, multifocal and recurrent osteoid osteoma treated using radiofrequency ablation. Case presentation A 39-year-old man with two-year history of left hip pain was admitted at our Institution. The pain was more intense during the night and partially relieved by salicylates. Pelvis CT demonstrated two lytic lesions (8 and 7 mm, respectively) with surrounding sclerotic reactive bone, both with a central focal area of high attenuation, located in the femoral neck and along the anterior portion of the acetabulum, r…

Osteoid osteomamusculoskeletal diseasesAdultMalemedicine.medical_specialtylcsh:Diseases of the musculoskeletal systemRadiofrequency ablationBiopsyOsteoma OsteoidBone NeoplasmsCase Reportlaw.inventionLesion03 medical and health sciences0302 clinical medicineRheumatologylawMedicineHumansOrthopedics and Sports MedicineComputed tomographyPelvisFemoral neck030203 arthritis & rheumatology030222 orthopedicsRadiofrequency AblationHipmedicine.diagnostic_testbusiness.industryFemur NeckMagnetic resonance imagingAcetabulummedicine.diseaseAcetabulumMagnetic Resonance ImagingPosterior columnbody regionsmedicine.anatomical_structureTreatment OutcomeOsteoid osteomaRetreatmentRadiologylcsh:RC925-935medicine.symptomNeoplasm Recurrence LocalbusinessTomography X-Ray ComputedBMC musculoskeletal disorders
researchProduct

A rare case of peri-implant distal radius fracture☆

2021

A peri-implant fracture near the volar plate of distal radius represent a very rare injury. The main factor of this lesion is high energy trauma on the wrist. We report a case of a 61-year-old woman with a peri-implant fracture located just proximally to the plate and a fracture of the ulnar head that occurred after a simple fall. The patient was surgically treated by plate and screws removal. The fracture was fixed using a longer volar plate for the radial fracture and a plate for the head ulnar fracture. Different factors such as osteoporosis, BMI and screw position could influence the fracture pattern. However, considering growing use of plates for distal radius fracture fixation, the fr…

Osteoporosislcsh:SurgeryUlnar headCase ReportWristCritical Care and Intensive Care MedicinePeri-implant radius fracture03 medical and health sciencesFixation (surgical)0302 clinical medicineRare caseSettore MED/33 - Malattie Apparato LocomotoreMedicineOrthopedics and Sports MedicineWrist fractureOrthodontics030222 orthopedicsScrew positionbusiness.industry030208 emergency & critical care medicinelcsh:RD1-811medicine.diseaseRadius and ulna fracturebody regionsmedicine.anatomical_structureRadius hardware substitutionEmergency MedicineDistal radius fractureImplantbusinessTrauma Case Reports
researchProduct

Non-metallic implant for patellar fracture fixation: A systematic review

2016

Abstract Introduction Despite good clinical outcome proposals, there has been relatively little published regarding the use of non-metallic implant for patellar fracture fixation. The purpose of the study was to perform a systematic literature review to summarize and evaluate the clinical studies that described techniques for treating patella fractures using non-metallic implants. Methods A comprehensive literature search was systematically performed to evaluate all studies included in the literature until November 2015. The following search terms were used: patellar fracture, patella suture, patella absorbable, patella screw, patella cerclage. Two investigators independently reviewed all a…

Patellar fractureReoperationmedicine.medical_specialtyBiocompatible MaterialsKnee InjuriesBone healingImplant removalFracture Fixation InternalFractures Bone03 medical and health sciencesFixation (surgical)0302 clinical medicineTension bandFracture fixationSettore MED/33 - Malattie Apparato LocomotoreHumansMedicineSuture fixation030212 general & internal medicineGeneral Environmental ScienceFracture HealingFibrous joint030222 orthopedicsbusiness.industryPatellamusculoskeletal systemmedicine.diseaseImplant removalSurgeryKnee fractureTreatment OutcomeSystematic reviewmedicine.anatomical_structureNon-metallic implantFiberWireGeneral Earth and Planetary SciencesPatella fractureImplantKnee ProsthesisbusinessInjury
researchProduct

Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders

2018

Background/Aims To evaluate the intra- and interrater reliability (I-IR) of sagittal spinopelvic parameters from digital full-spine plain radiographs with basic software tools in an unselected adult population with degenerative spinal complaints who were evaluated for surgery. Methods Forty-nine adult full-spine digital radiographs were measured twice by 3 independent observers, including an experienced spine surgeon, an experienced radiologist, and a resident orthopedic surgeon. Clinical picture archiving and communication system workstations and software tools were used and landmarks were set manually. The I-IR of the sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), …

Pelvic tiltmedicine.medical_specialtyIntraclass correlationradiographic imagediagnostic imagingRadiographyScoliosis/diagnostic imagingskolioosiSurgical planninglcsh:RC346-42903 medical and health sciences0302 clinical medicineselkäsairaudetmedicinestandarditta315lcsh:Neurology. Diseases of the nervous systemOrthodontics030222 orthopedicsscoliosisbusiness.industrysoftwareadultröntgentutkimusta3141RepeatabilitySagittal planeobserver variationInter-rater reliabilitymedicine.anatomical_structurekuvantaminenOrthopedic surgerystandardsSoftware/standardsOriginal ArticleSurgeryNeurology (clinical)reproducibility of resultsbusinessdiagnoosi030217 neurology & neurosurgeryNeurospine
researchProduct

Gait Symmetry Analysis in Patients after Treatment of Pilon Fractures by the Ilizarov Method

2021

The aim of this study was to comprehensively assess the gait parameters in patients who had undergone treatment of pilon fractures by the Ilizarov method. We analyzed gait parameters in patients who had undergone treatment for pilon fractures by the Ilizarov method

Physics and Astronomy (miscellaneous)General MathematicspedobarographySTRIDEgaitPilon fracture03 medical and health sciences0302 clinical medicineGait (human)Ilizarov methodComputer Science (miscellaneous)medicineTibiaPedobarographysymmetryOrthodontics030222 orthopedicspilon fracturebusiness.industrylcsh:MathematicsForefootBiomechanicslcsh:QA1-939medicine.diseaseChemistry (miscellaneous)Cadencebusinesshuman activitiestibia030217 neurology & neurosurgerySymmetry
researchProduct