Search results for " Oxygen"

showing 10 items of 1626 documents

Cardiorespiratory Fitness and the Risk of Serious Ventricular Arrhythmias: A Prospective Cohort Study.

2019

Cardiorespiratory fitness (CRF) is an established risk factor for cardiovascular disease outcomes. However, the relationship of CRF with risk of ventricular arrhythmias (VAs) is unknown. We aimed to assess the prospective association of CRF with the risk of serious VAs. Cardiorespiratory fitness, as measured by maximal oxygen uptake, was assessed using a respiratory gas exchange analyzer in 2299 middle-aged men in the Kuopio Ischemic Heart Disease prospective cohort. We corrected for within-person variability in CRF levels using data from repeated measurements 11 years apart. During median follow-up of 25.3 years (interquartile range, 18.7-27.2 years), 73 serious VAs were recorded. The age-…

rytmihäiriötAdultMalemedicine.medical_specialtyRegression dilutionRisk AssessmentOxygen ConsumptionInterquartile rangeRisk FactorsInternal medicineMedicineHumansregression dilutionLongitudinal StudiesProspective StudiesRisk factorProspective cohort studyProportional Hazards Modelscardiorespiratory fitnessbusiness.industryIncidenceventricular arrhythmiasHazard ratioCardiorespiratory fitnessArrhythmias Cardiacta3142General Medicineta3121Middle Agedfyysinen kuntoBlood pressurerisk factorCardiorespiratory Fitnessmaximal oxygen uptakesydän- ja verisuonitauditCardiologybusinessBody mass indexMayo Clinic proceedings
researchProduct

Radiation induced generation of Non-Bridging Oxygen Hole Center: intrinsic and extrinsic processes

2006

silica irradiation Non-Bridging Oxygen Hole Center photoluminescence
researchProduct

Phonon Coupling Properties of Non Bridging Oxygen Hole Centers at a Silica Surface Probed by Site-Selective Luminescence Excitation

2008

silica non bridging oxygen hole center site-selective luminescence phonon coupling
researchProduct

Luminescenza risolta in tempo del non bridging oxygen hole center in silice: proprietà di volume e di superficie

2007

silica non bridging oxygen hole center time resolved luminescence
researchProduct

Zero phonon line associated with Non Bridging Oxygen Hole Center in silica: comparison between bulk and surface properties

2008

silicanon bridging oxygen hole centerzero phonon line
researchProduct

Resonance Raman of oxygen dangling bonds in amorphous silicon dioxide

2017

We investigate the origin of a resonance Raman band induced by ionizing radiation in amorphous silicon dioxide (silica glass), which can be detected under ultraviolet laser excitation. A silica sample, rich of oxygen-excess related defects, was prepared by treating some length of a pure-silica-core multimode fiber in an O2 atmosphere (at high temperature and pressure) and by irradiating it with X-rays at 10 MGy(SiO2) dose. A micro-Raman study revealed a gaussian band peaking at 896 cm−1 with a full width at half maximum of 32 cm−1, which could be detected by exciting the sample with the 325-nm line of a HeCd laser. This spectral feature is absent in the Raman spectra performed with the 442-…

silicapoint defectSettore FIS/01 - Fisica Sperimentalenon-bridging oxygenMaterials Science (all)Spectroscopyresonance Raman
researchProduct

First measurements of field metabolic rate in wild juvenile fishes show strong thermal sensitivity but variations between sympatric ecotypes

2021

The relationship between physiology and temperature has a large influence on population-level responses to climate change. In natural settings, direct thermal effects on metabolism may be exaggerated or offset by behavioural responses influencing individual energy balance. Drawing on a newly developed proxy, we provide the first estimates of the thermal performance curve of field metabolism in a wild fish. We investigate the thermal sensitivity of field metabolic rate in two sympatric, genetically distinct ecotypes of Atlantic cod from the Skagerrak coast of southern Norway. The combined ecotype median of field metabolic rate increased with increasing temperature until around 16°C, coincide…

stable oxygen isotopeEcotypeZoologymetabolic rangeBiologystable carbon isotopemedicine.anatomical_structureotolithSympatric speciationField metabolic ratemedicineJuvenileSensitivity (control systems)Ecology Evolution Behavior and Systematicsphenotypic performanceOtolithOikos
researchProduct

Performance-related physiological changes induced by one year of endurance training in young athletes

2023

IntroductionAlthough maximal oxygen uptake (VO2max) is generally recognized as the single best indicator of aerobic fitness in youth, interpretation of this parameter and the extent to which it can be improved by training remain controversial, as does the relative importance of VO2max for performance in comparison to other factors such as power production. Here, we examined the influence of endurance training on the VO2max, muscle power and sports-related performance of cross-country skiers attending a school specializing in sports, as well as potential relationships between any changes observed to one another and/or to perceived stress scale (Cohen) and certain blood parameters.MethodsOn t…

suorituskykyyouthPhysiologyIdrottsvetenskapkestävyysharjoittelusport-specificPublic Health Environmental and Occupational HealthPhysical Therapy Sports Therapy and Rehabilitationadolescent & youthhiihtonuoretTourism Leisure and Hospitality ManagementAnthropologyadolescentVO2max (maximal oxygen uptake)maksimaalinen hapenottonuoruusOrthopedics and Sports Medicinecross-country skiingSport and Fitness Sciencesdouble poling performanceurheilijat
researchProduct

Luminescence Properties of Non Bridging Oxygen Hole Centers at a Silica Surface

2008

surface defectnon bridging oxygen hole centerluminescenceSilicabulk defect
researchProduct

Establishing a New ECMO Referral Center Using an ICU-Based Approach: A Feasibility and Safety Study

2022

Background: A high-volume center with a multidisciplinary team is regarded as the optimal place for providing extracorporeal membrane oxygenation (ECMO). We hypothesize that an ECMO center can also be successfully created and subsequently developed entirely by intensivists in a mid-size mixed intensive care unit (ICU). Methods: A model was created for setting up a new ECMO referral center within the structure of an existing mixed ICU in a tertiary hospital. A retrospective analysis was carried out of the first 33 patients treated in the initial period of the center’s activity, from mid 2018 to the end of 2020. Results: An ECMO center was established and developed entirely based on the resou…

surgical procedures operativeHealth Information ManagementLeadership and ManagementHealth PolicyHealth Informaticscritical care; healthcare; intensive care unit; extracorporeal membrane oxygenation; ECMOHealthcare; Volume 10; Issue 3; Pages: 414
researchProduct