Search results for " PLASMA"

showing 10 items of 2522 documents

Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography

1997

Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03–0.09 μg/L using a 50 mL sample.The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10–50…

Detection limitChromatographyIon chromatographyIsotope dilutionBromateBiochemistrychemistry.chemical_compoundchemistryBromideStandard additionmedia_common.cataloged_instanceEuropean unionInductively coupled plasma mass spectrometrymedia_commonFresenius' Journal of Analytical Chemistry
researchProduct

Development of an ICP−IDMS Method for Dissolved Organic Carbon Determinations and Its Application to Chromatographic Fractions of Heavy Metal Complex…

1998

A sensitive and fast method for direct determinations of dissolved organic carbon (DOC) in bulk samples and in chromatographically separated fractions by inductively coupled plasma isotope dilution mass spectrometry (ICP−IDMS) is developed. A 13C-enriched spike solution of benzoic acid is used for the isotope dilution step. Equal ionization efficiencies are obtained for carbon, independent of the type and molecular weight of the dissolved organic substance, which is the most important precondition for DOC determinations by ICP−IDMS. The detection limits achieved are 0.3 mg L-1 for bulk analyses and 7 × 10-4 μg s-1 for transient signals of chromatographic peaks. The results for different wat…

Detection limitChromatographyIsotopeChemistryAnalytical chemistrychemistry.chemical_elementIsotope dilutionMass spectrometryAnalytical Chemistrychemistry.chemical_compoundDissolved organic carbonInductively coupled plasmaCarbonBenzoic acidAnalytical Chemistry
researchProduct

Simultaneous determination of hydride and non-hydride forming elements by inductively coupled plasma optical emission spectrometry

2011

e percentagens de recuperacao entre 97 e 103%. A aplicabilidade do sistema foi demonstrada na determinacao simultânea de Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Zn, As, Bi, Sb, Se e Te em amostras certificadas para elementos tracos, NIST 1549 (leite em po desnatado), NIST 1570a (folhas de espinafre), DORM-2 (musculo de cacao) e TORT-2 (hepatopâncreas de lagosta). Os resultados obtidos foram concordantes com os teores certificados. The operating characteristics of a dual nebulization system were studied including instrumental and chemical conditions for the hydride generation and analytical figures of merit for both, hydride and non hydride forming elements. Analytical performance of the neb…

Detection limitHydrideChemistryInductively coupled plasma atomic emission spectroscopyRelative standard deviationAnalytical chemistryGeneral ChemistryInductively coupled plasmaOptical emission spectrometryJournal of the Brazilian Chemical Society
researchProduct

Development of a new method for the separation of vanadium species and chloride interference removal using modified silica capillaries-DIN-ICP-MS

2004

Abstract A new on-line method for the separation of vanadium (IV) and vanadium (V) as well as for the removal of ClO+ mass spectral interference on vanadium determination by quadrupole-ICP-MS has been developed. The sample introduction system consists of a modified fused silica capillary coupled to a direct injection nebuliser (DIN), between the solvent delivery system and the ICP. Fused silica capillaries were treated with different anion and cation exchanger reagents and were tested for the retention of Cl− and the separation of vanadium ions at μg l−1 levels. A suitable strong anion exchanger functional group (3-aminopropyltrimethoxy silane) was selected. Chlorine anions were retained in…

Detection limitIon exchangeAnalytical chemistrychemistry.chemical_elementVanadiumChlorideAnalytical ChemistrySolventchemistryReagentChlorinemedicineInductively coupled plasma mass spectrometrySpectroscopymedicine.drugMicrochemical Journal
researchProduct

Development of an ICP-IDMS method for accurate routine analyses of toxic heavy metals in polyolefins and comparison with results by TI-IDMS

2000

An inductively coupled plasma isotope dilution mass spectrometric (ICP-IDMS) method was developed as a suitable method - with respect to its sensitivity, precision, accuracy, and time-consumption - for the analysis of toxic heavy metal traces (Pb, Cd, Cr, and Hg) in polyolefins. Results for Pb, Cd, and Cr were compared with those obtained by thermal ionization isotope dilution mass spectrometry (TI-IDMS), which was used as a reference method. Because of its high first ionization potential and its high volatility mercury could not be determined by TI-IDMS. A multi-element spike solution, containing isotopically enriched 206Pb, 116Cd, 53Cr, and 201Hg, was used for the isotope dilution step. D…

Detection limitIsotopeChemistryAnalytical chemistryThermal ionizationchemistry.chemical_elementAlkenesIsotope dilutionMass spectrometrySensitivity and SpecificityBiochemistryHazardous SubstancesMass SpectrometryMercury (element)IsotopesPolyethyleneMetals HeavyInductively coupled plasmaChemical decompositionFresenius' Journal of Analytical Chemistry
researchProduct

Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser …

2003

Four alternative analytical procedures for the determination of ten important trace impurities (Mg, Cr, Fe, Cu, Zn, Sr, Zr, Cd, Ba, and Pb) in pure alkaline earth fluoride powders were applied using high-resolution inductively coupled plasma mass spectrometry (ICP-MS). Two procedures are based on a wet-chemical microwave digestion with boric acid and quantification by the standard addition technique and isotope dilution mass spectrometry (IDMS), respectively. In addition, analyses are also performed by laser ablation as a direct solid sampling technique applying matrix-matched external calibration as well as isotope dilution of the powdered sample. For most elements good agreement between t…

Detection limitLaser ablationChemistryStandard additionAnalytical chemistryAnalytical proceduresSample preparationIsotope dilutionMicrowave digestionBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryAnalytical and bioanalytical chemistry
researchProduct

Development of an isotope dilution laser ablation ICP-MS method for multi-element determination in crude and fuel oil samples

2009

An inductively coupled plasma isotope dilution mass spectrometric (ICP-IDMS) method with direct introduction of the isotope-diluted sample into the plasma by laser ablation was developed for accurate, sensitive, fast, and simultaneous determination of trace metals in different oil samples. Metallo-organic solutions of isotope spikes (50V, 53Cr, 65Cu, 57Fe, 62Ni, 68Zn, 113Cd, 117Sn, and 206Pb) were prepared from corresponding aqueous stock solutions by using liquid–liquid extraction of complexed metal ions in isobutyl methyl ketone. The isotope-diluted sample was absorbed by a cellulose material, which was fixed in a special PTFE holder for ablation, using a laser system with high ablation r…

Detection limitLaser ablationChromatographyChemistryAnalytical chemistryVanadiumchemistry.chemical_elementFuel oilFractionationIsotope dilutionAnalytical ChemistryInductively coupled plasmaInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Validating quantitative PCR assays for cell-free DNA detection without DNA extraction: Exercise induced kinetics in systemic lupus erythematosus pati…

2021

ABSTRACTCirculating cell-free DNA (cfDNA) has been investigated as a screening tool for many diseases. To avoid expensive and time-consuming DNA isolation, direct quantification PCR assays can be established. However, rigorous validation is required to provide reliable data in the clinical and non-clinical context. Considering International Organization for Standardization, as well as bioanalytical method validation guidelines we provide a comprehensive procedure to validate assays for cfDNA quantification from unpurified blood plasma. A 90 and 222 bp assay was validated to study the kinetics of cfDNA after exercise in patients with systemic lupus erythematosus. The assays showed ultra-low …

Detection limitOncologymedicine.medical_specialtyBioanalysisbusiness.industryContext (language use)RepeatabilityDNA extractionReal-time polymerase chain reactionCell-free fetal DNAInternal medicineBlood plasmamedicinebusiness
researchProduct

Determination of phytic acid and its degradation products by ion-pair chromatography (IPC) coupled to inductively coupled plasma-sector field-mass sp…

2004

We developed a method for the determination of phytic acid (IP6) and its degradation products (IP1-IP5) by ion-pair chromatography coupled to a double focussing inductively coupled plasma-sector field-mass spectrometer (ICP-SF-MS). For the detection of the phosphorus species a mass resolution (m/Δm) of 4000 was needed in order to separate the 31P+ signal from the interfering clusterions. The separation of the six phosphorus species was enabled by a gradient elution using tetrabutylammonium hydroxide (TBA) as ion-pair reagent. Calibration data were reported and a detection limit of 230 ng g−1 for IP6 could be obtained. The method was firstly proved for a hydrolyzate of commercially available…

Detection limitPhytic acidChromatographyTetrabutylammonium hydroxidePhosphorusfood and beverageschemistry.chemical_elementMass spectrometryAnalytical Chemistrychemistry.chemical_compoundchemistryReagentInositolInductively coupled plasmaSpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Simultaneous determinations of zirconium, hafnium, yttrium and lanthanides in seawater according to a co-precipitation technique onto iron-hydroxide.

2013

Very low concentrations (pg mL(-1) or sub-pg mL(-1) level) along with the high salinity are the main problems in determining trace metal contents in seawater. This problem is mainly considered for investigations of naturally occurring YLOID (Y and Lanthanides) and Zr and Hf in order to provide precise and accurate results. The inductively coupled plasma mass spectrometry (ICP-MS), both in high and low resolution, offers many advantages including simultaneous analyses of all elements and their quantitative determination with detection limits of the order of pg mL(-1). However in the analysis of YLOID in seawater, a better determination needs an efficient combination of ICP-MS measurement wit…

Detection limitQuality ControlZirconiumSpectrophotometry AtomicAnalytical chemistrychemistry.chemical_elementFlocculationYttriumFerric CompoundsLanthanoid Series ElementsAnalytical ChemistryWorking rangeHafniumTrace ElementsCertified reference materialschemistryLimit of DetectionSeawaterSeawaterYttriumZirconiumInductively coupled plasma mass spectrometryHafniumTalanta
researchProduct