Search results for " Phase"

showing 10 items of 1862 documents

Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review

2016

Liquid chromatography with single columns often does not succeed in the analysis of complex samples, in terms of resolution and analysis time. A relatively simple solution to enhance chromatographic resolution is the modulation of the stationary phase through the serial coupling of columns. This can be implemented with any type of column using compatible elution conditions and conventional instruments. This review describes the key features of column coupling and published procedures, where two or more columns were coupled in series to solve separation problems. In all reports, the authors could not resolve their samples with single columns, whereas significant enhancement in chromatographi…

Chromatography010405 organic chemistryChemistryElution010401 analytical chemistryKey features01 natural sciencesBiochemistryMass spectrometricDead volume0104 chemical sciencesAnalytical ChemistryVolumetric flow rateTwo-dimensional chromatographyStationary phaseEnvironmental ChemistryChromatography columnSpectroscopyAnalytica Chimica Acta
researchProduct

Optimization of experimental conditions for the identification of pesticide mixtures on six GLC columns

1994

ChromatographyCapillary columnChemistryStationary phaseAnalytical chemistryGeneral MedicineGas chromatographyPesticideRetention timeAnalytical Chemistry
researchProduct

Evaluation by HPLC-UV of Polar Pesticides in Rice Fields

1999

ChromatographyChemical PhenomenaChemistry PhysicalHealth Toxicology and MutagenesisPesticide ResiduesOryzaGeneral MedicineHydrogen-Ion ConcentrationPesticideToxicologyPollutionHigh-performance liquid chromatographySurface-Active AgentsSpainEnvironmental sciencePaddy fieldPolarSpectrophotometry UltravioletTrace analysisSample preparationSolid phase extractionPesticidesChromatography High Pressure LiquidHalf-LifeBulletin of Environmental Contamination and Toxicology
researchProduct

Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples

2016

Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: The fir…

ChromatographyChemistry010401 analytical chemistryClinical BiochemistryAnalytical chemistryAnalysis of organophosphate flame retardants in water by SPE and UHPLC–MS/MS using a trap column.solid phase extractionWater010501 environmental sciences01 natural sciencesTrap column0104 chemical sciencesOrganophosphate flame retardantsMedical Laboratory TechnologyWastewaterLC–MS/MSLiquid chromatography–mass spectrometryInterferencesLc ms msEnvironmental ScienceGas chromatographyUltra high pressureSolid phase extraction0105 earth and related environmental sciencesComputingMethodologies_COMPUTERGRAPHICSMethodsX
researchProduct

Flow Injection Fourier Transform Infrared Determination of Caffeine in Soft Drinks

1997

A fully automated procedure has been developed for FT-IR determination of caffeine in soft drinks. Samples are first degasified by filtration and then directly injected into a flow manifold and passed through a 100 mg C18 SPE cartridge, conditioned with methanol and water. After the cartridge has been cleaned with water, the caffeine is eluted with CHCl3 and stabilized with ethanol. The flow injection (FI) recording is obtained by measuring the absorbance at 1658 cm-1 with a baseline established at 1800 cm-1. Area values for the FI recording obtained between 0.4 and 1.4 min after sample injection are interpolated in the calibration graph of a series of aqueous standards of caffeine, which w…

ChromatographyChemistryCalibration curveElutionExtraction (chemistry)Analytical chemistryAnalytical Chemistrylaw.inventionAbsorbanceCartridgechemistry.chemical_compoundlawSolid phase extractionCaffeineFiltrationAnalytical Chemistry
researchProduct

Determination of phenoxy acid herbicides in drinking waters by HPLC and solid phase extraction

1998

Abstract An HPLC procedure for determining phenoxy acid herbicides in waters is described. A LichroSpher RP select B octadecyl-silane analytical column and spectrophotometric detection at 230 nm were used. Adequate retention was achieved with a mobile phase containing MeOH/phosphate buffer 10−2 M pH 2.5/PnOH (50/42/8, v/v). The herbicides were isolated from water samples by using a single solid phase extraction procedure with C18 solid-phase columns. An enrichment factor of 500 is achieved. The coefficients of variation of the method were generally lower than 2.7% at 0.4 μg L−1 herbicide concentration levels. Recoveries ranged between 93 and 118%. The results obtained indicate that the prop…

ChromatographyChemistryClinical BiochemistryPharmaceutical ScienceReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundDicambaSample preparationSolid phase extractionWater pollutionEnrichment factorQuantitative analysis (chemistry)
researchProduct

Organochlorine residue analysis of commercial milks by capillary gas chromatography

1991

The determination of organochlorine pesticides and polychlorinated biphenyls in milks requires the use of efficient extraction methods. A rapid procedure has been developed, based on extraction of organochlorine residues from milk on to octadecylsilica solid phase extraction cartridges and elution with hexane. The addition of different organic solvents to the milk before solid phase extraction has been studied. The use of methanol to disrupt the fat globules enables almost complete recovery of the residues with minimum extraction of fatty substances. Recovery experiments were performed for eighteen compounds present at ppb levels in whole, two per cent, and skimmed milks. The average recove…

ChromatographyChemistryElutionGeneral Chemical EngineeringExtraction (chemistry)food and beveragesPesticideHexanechemistry.chemical_compoundfluids and secretionsSolid phase extractionGlobules of fatGas chromatographyMethanolJournal of High Resolution Chromatography
researchProduct

Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…

2002

A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…

ChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Molecularly imprinted polymerReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryClenbuterolmedicineAnimalsCattleClenbuterolSpectrophotometry UltravioletSample preparationSolid phase extractionAdrenergic alpha-AgonistsChromatography High Pressure Liquidmedicine.drugJournal of Chromatography A
researchProduct

Solid-Phase Extraction Techniques for Assay of Diuretics in Human Urine Samples

1991

Abstract Solid-phase extraction techniques were evaluated for the treatment of urine samples in the analysis of diuretics before injection into an HP-Hypersyl ODS-C18 column. Six different reversed-phase extraction columns were tested, and the results obtained are compared with those obtained in a classical liquid-liquid extraction with ethyl acetate. The solid-phase extraction procedures are the best overall choice for all the diuretics tested, due to their versatility, the minor time-consuming, and the good recovery percentages obtained. C18 and C8 packings give the highest recoveries for a majority of the diuretics studied. However, CH or PH columns, due to their greater selectivity, can…

ChromatographyChemistryElutionmedicine.medical_treatmentExtraction (chemistry)Ethyl acetateHigh-performance liquid chromatographyMatrix (chemical analysis)chemistry.chemical_compoundmedicineMolecular MedicineSolid phase extractionDiureticThiazidemedicine.drugJournal of Liquid Chromatography
researchProduct

Green Analytical Chemistry

2021

ChromatographyChemistryExtraction (chemistry)010401 analytical chemistryAnalytical chemistryAnalytical Chemistry (journal)02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesLiquid–liquid extractionGreen metricsSolid phase extraction0210 nano-technology
researchProduct