Search results for " Prosthesis"
showing 10 items of 441 documents
“Unlucky punch”: unexpected annular rupture during TAVR and successful treatment
2021
Although rare, annular rupture in TAVR is a feared and often unpredictable complication with relevant impact on in-hospital prognosis. Severe annular calcification is a common risk factor for annular rupture. We report on a case of annular rupture during TAVR with a balloon-expanded prosthesis in the absence of any annular calcification in the planning CT scan and illustrate the proposed pathomechanism as well as its successful immediate surgical management.
An International, Multicenter Retrospective Observational Study to Assess Technical Success and Clinical Outcomes of Patients Treated with an Endovas…
2022
Introduction: Type III endoleaks post-endovascular aortic aneurysm repair (EVAR) warrant treatment because they increase pressure within the aneurysm sac leading to increased rupture risk. The treatment may be difficult with regular endovascular devices. Endovascular aneurysm sealing (EVAS) might provide a treatment option for type III endoleaks, especially if located near the flow divider. This study aims to analyze clinical outcomes of EVAS for type III endoleaks after EVAR. Methods: This is an international, retrospective, observational cohort study including data from 8 European institutions. Results: A total of 20 patients were identified of which 80% had a type IIIb endoleak and the r…
Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction
2016
Background: To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods: A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm l…
Clinical retrospective study of dental implant removal : do patients who require implant removal desire implant prosthesis again?
2020
Background This study investigated the causes of dental implant removal due to complications, and examined whether patients who had dental implant removal desired re-implant prosthesis treatments. Material and Methods A retrospective case–control study was conducted on patients who had their dental implants removed. We investigated whether the removed dental implant was replaced with other implant prostheses. Age, sex, diabetes, smoking, implant site distribution, reason for implant removal, and blade and root-form implants were categorized as predictive variables. The outcome variable was desire for re-implantation or use of other prosthetic methods after implant removal. A logistic regres…
Predictability of short implants ( < 10 mm) as a treatment option for the rehabilitation of atrophic maxillae: a systematic review
2016
Background Short implants (< 10 mm) are one of the treatment options available in cases of limited vertical bone. A purpose of this paper is to evaluate the predictability of short implants as an alternative to technically molthough such implants are now widely used, there is controversy regarding their clinical reliability. There complex treatments in patients with atrophic maxillae, based on a systematic review of the literature and the analysis of the implant survival rates, changes in peri-implant bone level, and associated complications. It is postulated that short implants offer clinical results similar to those of longer implants. Material and Methods A Medline-PubMed search was made…
Quality assessment of systematic reviews regarding the effectiveness of zygomatic implants: an overview of systematic reviews
2020
Background Oral rehabilitation of atrophic maxillae features high complexity, for which there are several therapeutic modalities reported on scientific literature. Zygomatic implant placement is a viable option that features low morbidity and allows immediate prosthetic loading. The purpose of the present study was to determine the methodological quality of systematic reviews that assessed the effectiveness of zygomatic implants placed in atrophic maxillae. Material and Methods Searches were conducted on Medline via Pubmed, LILACS, Dare Cochrane, Scopus, and Sigle via Open Grey up to June 2019. Results Seven systematic reviews were eligible for Overview and comprised a total of 2313 patient…
Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes
2018
The following article: Jung, R.E., Al-Nawas, B., Araujo, M., Avila-Ortiz, G., Barter, S., Brodala, N., ... Windisch, P. (2018). Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes. Clinical Oral Implants Research, 29(S16), 69-77, can be accessed at https://doi.org/10.1111/clr.13342. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. Objectives: The aim of Working Group 1 was to address the influence of different local (implant length, diameter, and design) and systemic (medications) factors on clinical, radiographic, and patient‐re…
The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.
2003
To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…
A ten-year follow-up of the Reflection cementless acetabular component.
2008
We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…
In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.
2019
Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …