Search results for " Prosthesis"

showing 10 items of 441 documents

“Unlucky punch”: unexpected annular rupture during TAVR and successful treatment

2021

Although rare, annular rupture in TAVR is a feared and often unpredictable complication with relevant impact on in-hospital prognosis. Severe annular calcification is a common risk factor for annular rupture. We report on a case of annular rupture during TAVR with a balloon-expanded prosthesis in the absence of any annular calcification in the planning CT scan and illustrate the proposed pathomechanism as well as its successful immediate surgical management.

medicine.medical_specialtymedicine.medical_treatmentComputed tomographyProsthesis DesignProsthesisTranscatheter Aortic Valve ReplacementHumansMedicineRadiology Nuclear Medicine and imagingcardiovascular diseasesRisk factorHeart Valve Prosthesis Implantationmedicine.diagnostic_testbusiness.industryCalcinosisAortic Valve Stenosisequipment and suppliesmedicine.diseaseTreatment OutcomeAortic ValveHeart Valve Prosthesiscardiovascular systemsense organsRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicineComplicationbusinessCalcificationEchocardiography
researchProduct

An International, Multicenter Retrospective Observational Study to Assess Technical Success and Clinical Outcomes of Patients Treated with an Endovas…

2022

Introduction: Type III endoleaks post-endovascular aortic aneurysm repair (EVAR) warrant treatment because they increase pressure within the aneurysm sac leading to increased rupture risk. The treatment may be difficult with regular endovascular devices. Endovascular aneurysm sealing (EVAS) might provide a treatment option for type III endoleaks, especially if located near the flow divider. This study aims to analyze clinical outcomes of EVAS for type III endoleaks after EVAR. Methods: This is an international, retrospective, observational cohort study including data from 8 European institutions. Results: A total of 20 patients were identified of which 80% had a type IIIb endoleak and the r…

medicine.medical_specialtymedicine.medical_treatmentTechnical successClinical Investigationsendoleak030204 cardiovascular system & hematologyProsthesis DesignEndovascular aneurysm repair030218 nuclear medicine & medical imagingendovascular aneurysm repair03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmabdominal aortic aneurysmRisk FactorsmedicineMANAGEMENTHumansabdominal aortic aneurysm; aneurysm; endoleak; endovascular aneurysm repair; reinterventionRadiology Nuclear Medicine and imagingRupture riskcardiovascular diseasesRetrospective StudiesreinterventionREPAIRAortic aneurysm repairABDOMINAL AORTIC-ANEURYSMSIncrease pressurebusiness.industryEndovascular ProceduresRetrospective cohort studymedicine.diseaseAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisTreatment Outcomecardiovascular systemaneurysmREPORTING STANDARDSSurgeryStentsCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction

2016

Background: To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods: A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm l…

medicine.medical_treatmentDentistryOdontologíaRetrospective data03 medical and health sciences0302 clinical medicinePatient satisfactionGeneral satisfactionMaxillaAtrophic maxillaHumansJaw EdentulousMedicine030212 general & internal medicineImplant loadingGeneral DentistryRetrospective StudiesPatient comfortDental ImplantsZygomaRehabilitationbusiness.industryResearchDental Implantation Endosseous030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludTreatment OutcomeOtorhinolaryngologyPatient SatisfactionMaxillaUNESCO::CIENCIAS MÉDICASSurgeryDental Prosthesis Implant-SupportedOral SurgerybusinessFollow-Up Studies
researchProduct

Clinical retrospective study of dental implant removal : do patients who require implant removal desire implant prosthesis again?

2020

Background This study investigated the causes of dental implant removal due to complications, and examined whether patients who had dental implant removal desired re-implant prosthesis treatments. Material and Methods A retrospective case–control study was conducted on patients who had their dental implants removed. We investigated whether the removed dental implant was replaced with other implant prostheses. Age, sex, diabetes, smoking, implant site distribution, reason for implant removal, and blade and root-form implants were categorized as predictive variables. The outcome variable was desire for re-implantation or use of other prosthetic methods after implant removal. A logistic regres…

medicine.medical_treatmentDentistryProsthesisImplant removalOutcome variablemedicineHumansDental Restoration FailureDental implantGeneral DentistryRetrospective StudiesDental ImplantsImplant prosthesisbusiness.industryResearchDental Implantation EndosseousRetrospective cohort study:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyDental Prosthesis DesignCase-Control StudiesUNESCO::CIENCIAS MÉDICASSurgeryImplantDental Prosthesis Implant-SupportedPredictive variablesbusinessImplantologyFollow-Up Studies
researchProduct

Predictability of short implants ( < 10 mm) as a treatment option for the rehabilitation of atrophic maxillae: a systematic review

2016

Background Short implants (< 10 mm) are one of the treatment options available in cases of limited vertical bone. A purpose of this paper is to evaluate the predictability of short implants as an alternative to technically molthough such implants are now widely used, there is controversy regarding their clinical reliability. There complex treatments in patients with atrophic maxillae, based on a systematic review of the literature and the analysis of the implant survival rates, changes in peri-implant bone level, and associated complications. It is postulated that short implants offer clinical results similar to those of longer implants. Material and Methods A Medline-PubMed search was made…

medicine.medical_treatmentMEDLINEDentistryOdontologíaReview03 medical and health sciences0302 clinical medicineMaxillaHumansMedicineDental Restoration Failure030212 general & internal medicineBone levelGeneral DentistryDental ImplantsImplantes dentalesRehabilitationbusiness.industryDental Implantation EndosseousDental prosthesisReproducibility of ResultsTreatment options030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludShort implantsOtorhinolaryngologyMaxillaUNESCO::CIENCIAS MÉDICASOdontología restauradoraSurgeryDental Prosthesis Implant-SupportedImplantOral SurgeryAtrophybusiness
researchProduct

Quality assessment of systematic reviews regarding the effectiveness of zygomatic implants: an overview of systematic reviews

2020

Background Oral rehabilitation of atrophic maxillae features high complexity, for which there are several therapeutic modalities reported on scientific literature. Zygomatic implant placement is a viable option that features low morbidity and allows immediate prosthetic loading. The purpose of the present study was to determine the methodological quality of systematic reviews that assessed the effectiveness of zygomatic implants placed in atrophic maxillae. Material and Methods Searches were conducted on Medline via Pubmed, LILACS, Dare Cochrane, Scopus, and Sigle via Open Grey up to June 2019. Results Seven systematic reviews were eligible for Overview and comprised a total of 2313 patient…

medicine.medical_treatmentMEDLINEDentistryScientific literatureReview03 medical and health sciences0302 clinical medicinemedicineMucositisMaxillaHumansJaw EdentulousSinusitisGeneral DentistryDental ImplantsRehabilitationbusiness.industryDental prosthesisDental Implantation Endosseous030206 dentistrymedicine.disease:CIENCIAS MÉDICAS [UNESCO]Maxillary SinusitisSystematic reviewOtorhinolaryngologyMaxillaUNESCO::CIENCIAS MÉDICASSurgeryDental Prosthesis Implant-SupportedbusinessImplantologyFollow-Up StudiesSystematic Reviews as TopicMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes

2018

The following article: Jung, R.E., Al-Nawas, B., Araujo, M., Avila-Ortiz, G., Barter, S., Brodala, N., ... Windisch, P. (2018). Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes. Clinical Oral Implants Research, 29(S16), 69-77, can be accessed at https://doi.org/10.1111/clr.13342. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. Objectives: The aim of Working Group 1 was to address the influence of different local (implant length, diameter, and design) and systemic (medications) factors on clinical, radiographic, and patient‐re…

medicine.medical_treatmentOsteoporosisbiological complicationsDentistryOsteoporosis/complicationsmeta-analysilaw.inventionProton Pump Inhibitors/adverse effects0302 clinical medicineRandomized controlled triallawRadiography DentalDental Restoration FailureDental implanthumans610 Medicine &amp; healthclinical decision-makingdental implantDiphosphonatesnarrow diameter3504 Oral SurgeryJaw Edentulous Partially05 social sciencesDental Implantation EndosseousImplant failuredrugsmall dental implantVDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830failureclinical decision‐makingDiphosphonates/adverse effectsMeta-analysisrandomized controlled trials/dk/atira/pure/sustainabledevelopmentgoals/good_health_and_well_beingepidemiologymedicationOral SurgerySelective Serotonin Reuptake InhibitorsConsensusreview610 Medicine & healthsurvival03 medical and health sciences10068 Clinic of Reconstructive DentistrySDG 3 - Good Health and Well-beingdental implants0502 economics and businessmedicineshort dental implantsHumansbiological complicationPatient Reported Outcome MeasureshumanSurvival ratesmall dental implantsDental Implantsbusiness.industryJaw Edentulous Partially/rehabilitationshort dental implantProton Pump Inhibitors030206 dentistrymedicine.diseaseendosseous implantSurvival AnalysisVDP::Medical disciplines: 700::Clinical dentistry disciplines: 830Dental Prosthesis Designmeta‐analysisRelative riskrandomized controlled trialOsteoporosis050211 marketingImplantSerotonin Uptake Inhibitors/adverse effectsbusinessosteotomySystematic Reviews as Topic
researchProduct

The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.

2003

To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…

musculoskeletal diseasesAdultMaleAccuracy and precisionmedicine.medical_specialtymedicine.medical_treatmentRadiographyArthroplasty Replacement HipProsthesisRadiostereometric AnalysisForeign-Body MigrationmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingFemurFemurDigital radiographyAgedOrthodonticsReproducibilitybusiness.industryReproducibility of ResultsMiddle Agedmusculoskeletal systemSurgeryProsthesis FailureRadiographic Image EnhancementOrthopedic surgeryFemaleHip ProsthesisbusinessSkeletal radiology
researchProduct

A ten-year follow-up of the Reflection cementless acetabular component.

2008

We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…

musculoskeletal diseasesAdultmedicine.medical_specialtyAcetabulum; Adult; Aged; Aged 80 and over; Arthroplasty Replacement Hip; Bone Cements; Equipment Failure Analysis; Follow-Up Studies; Hip Joint; Humans; Middle Aged; Osteoarthritis Hip; Prosthesis Design; Prosthesis Failure; Statistics as Topic; Time Factors; Hip ProsthesisTime FactorsArthroplasty Replacement HipStatistics as TopicProsthesis DesignOsteoarthritis HipmedicineHumansOrthopedics and Sports MedicineSurvival analysisPelvisFixation (histology)AgedAged 80 and overbusiness.industryBone CementsAcetabulumMiddle AgedConfidence intervalSurgeryProsthesis FailureEquipment Failure AnalysisReflection acetabular component hipmedicine.anatomical_structureAcetabular componentRadiological weaponCohortOrthopedic surgerySurgeryHip JointHip ProsthesisbusinessFollow-Up StudiesThe Journal of bone and joint surgery. British volume
researchProduct

In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.

2019

Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …

musculoskeletal diseasesDental ImplantsUltrasound deviceMaterials scienceImplant prosthesisBone Screws030206 dentistryThread (computing)Esthetics Dentalmusculoskeletal systemequipment and suppliescomputer.software_genreExtractor03 medical and health sciencesLoad testingsurgical procedures operative0302 clinical medicineCoronal planeExtraction methodsOral SurgerycomputerFracture typeBiomedical engineeringThe Journal of prosthetic dentistry
researchProduct