Search results for " Radio"
showing 10 items of 2362 documents
Emergency radiology: straightening of the cervical spine in MDCT after trauma--a sign of injury or normal variant?
2016
To evaluate whether straightening of the cervical spine (C-spine) alignment after trauma can be considered a significant multidetector CT (MDCT) finding.160 consecutive patients after C-spine trauma admitted to a Level 1 trauma centre received MDCT according to Canadian Cervical Spine Rule and National Emergency X-Radiography Utilization Study indication rule; subgroups with and without cervical collar immobilization (CCI +/-) were compared with a control group (n = 20) of non-traumatized patients. Two independent readers evaluated retrospectively the alignment, determined the absolute rotational angle of the posterior surface of C2 and C7 (ARA C2-7) and grouped the results for lordosis (-1…
Modulation of [18F]fluorodopa (FDOPA) kinetics in the brain of healthy volunteers after acute haloperidol challenge.
2006
In animal studies, acute antipsychotic treatment was shown to enhance striatal DOPA-decarboxylase (DDC) activity. However, this phenomenon has not been demonstrated in humans by positron emission tomography (PET). Therefore, we investigated acute haloperidol effects on DDC activity in humans using [18F]fluorodopa (FDOPA) PET. Nine healthy volunteers were scanned with FDOPA in drug-free baseline conditions and after 3 days of haloperidol treatment (5 mg/day). A continuous performance test (CPT) was administered in both conditions. The net blood-brain clearance of FDOPA (K(in)app) in striatum, mesencephalon, and medial prefrontal cortex was calculated by volume-of-interest analysis. The macro…
Striatal and extrastriatal D2/D3-receptor-binding properties of ziprasidone: a positron emission tomography study with [18F]Fallypride and [11C]raclo…
2008
To elucidate the Batypicality( of ziprasidone, its striatal and extrastriatal D2/D3-receptor binding was characterized in patients with schizophrenia under steady-state conditions. These data were compared with striatal receptor occupancy values after single-dose ziprasidone ingestion in healthy controls. ( 18 F)fallypride positron emission tomography (PET) recordings were obtained in 15 patients under steady-state ziprasidone treatment at varying time points after the last dose. Binding potentials were calculated for striatal and extrastriatal regions. D2/D3-receptor occupancies were expressed relative to binding potentials in 8 unmedicated patients. In a parallel ( 11 C)raclopride-PET stu…
Opioid receptor PET reveals the psychobiologic correlates of reward processing.
2008
Little is known about the neurobiologic correlates of human personality. On the basis of the key role of the central opioidergic system in addiction and substance abuse, we investigated the relationship between certain personality traits that are supposed to be relevant in addiction and the opioid receptor status in healthy subjects.We investigated 23 healthy male volunteers who were extensively clinically tested to exclude substance abuse. All of the subjects underwent 1 PET scan with the subtype-nonselective opioidergic radioligand 18F-fluoroethyl-diprenorphine under resting conditions without sensory or cognitive stimulation. Subsequently, the subjects were psychologically tested for the…
Detection of coronary artery calcifications predicting coronary heart disease: comparison of fluoroscopy and spiral CT.
1998
The aim of this study was to evaluate the clinical relevance of coronary artery calcifications detected by spiral CT, congruence with fluoroscopy (FS) and coronary angiography, and comparison with studies reporting on application of double-helical CT and ultrafast CT. Forty patients underwent spiral CT (2-mm slice thickness, table feed 3 mm/s), coronary angiography, and FS (performed in the usual manner). Stenosis and calcifications were evaluated semiquantitatively. Nineteen patients suffering from a stenosis ≥ 75 % were verified at coronary angiography. All had coronary artery calcification on spiral CT. Fluoroscopy did not detect 8 of 19 patients with a stenosis ≥ 75 % (1 vessel: n = 1; …
Lacrimal gland herniation in Graves ophthalmopathy: a simple and useful MRI biomarker of disease activity
2019
Lacrimal gland (LG) involvement in patients with Graves ophthalmopathy (GO) has been considered as a potential cause of the associated GO symptoms and different studies demonstrated the LG involvement in patients with GO than healthy controls. The aim of this study was to evaluate LG involvement, through measurement of its herniation, using a magnetic resonance imaging (MRI) index, in patients with different GO activities. Thirty-two consecutive Caucasian patients affected by GO were enrolled and grouped in group A (16 with inactive GO, CAS < 3) and B (16 with active GO, CAS ≥ 3) according to their GO activity. All patients underwent clinical-endocrinological assessment, a complete ocular e…
Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.
2003
The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…
Identification of unknown dead bodies by X-ray image comparison of the skull using the X-ray simulation program FoXSIS.
2001
The aim of the study was to improve the objectivity of X-ray image comparison for the identification of unknown dead individuals. CT-data were collected for 30 macerated skulls. An already presented computer program which uses CT data to establish virtual X-ray images was used to obtain X-rays with different beam angulations simulating rotation, dorsal flexion, and ventral flexion. Specific parameters were measured on the simulated images. The frontal sinus reveals the highest variability not only between the individual skulls but also within an individual skull in different positions. The most consistent parameters with respect to different positions were the skull breadth, the biorbital b…
Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…
2009
This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…
Diagnostic performance of reformatted isotropic thin-section helical CT images in the detection of superior semicircular canal dehiscence
2017
Purpose The purpose of this article is to assess the diagnostic performance of computed tomography (CT) reformatted images for detection of superior semicircular canal (SSC) dehiscence. Material and methods Forty-two patients, with sound- and/or pressure-induced vestibular symptoms, and 42 control participants underwent helical CT examination with a highly collimated beam (0.5 mm). Reformatted images of the vestibular labyrinth were obtained in the standard axial and coronal planes (group A images), and in a plane parallel and perpendicular to the SSC (group B images). Diagnostic performance obtained by evaluating the group A images alone and the group B images alone was analyzed by using t…