Search results for " Repair"

showing 10 items of 721 documents

Mitral valve therapy still surgical?

2015

Mitral regurgitation (MR) is the second most common valvular heart disease after aortic valve stenosis. With increased understanding of the heterogenic pathophysiology of MR, cardiac surgeons have developed various techniques that increase the likelihood of successful mitral valve repair (MVR). Nowadays, a rate of repair >90% may be reached in some mitral valve reference centres. In recent years, the introduction of transcatheter mitral valve intervention techniques has opened up new frontiers in mitral therapy, specifically in patients at high risk for standard surgery. Current percutaneous technologies for MVR have been developed on the basis of some of the surgical principles. Based on c…

medicine.medical_specialtyMitral valve repairMitral regurgitationPercutaneousbusiness.industryClinical outcomemedicine.medical_treatmentStandard treatmentMitraClipNew devicevalvular heart diseasemedicine.diseasemedicine.anatomical_structureAortic valve stenosisInternal medicineMitral valvecardiovascular systemmedicineCardiologyTranscatheter mitral valve therapybusinessCardiology and Cardiovascular MedicineMitral valve repairLong-term repair result
researchProduct

Diaphragmatic Hernia following Pediatric Liver Transplantation: An Underappreciated Complication Prone to Recur.

2020

Abstract Introduction Postoperative diaphragmatic hernia (DH) is a rare but potentially life-threatening complication following pediatric liver transplantation (LT). In the current literature, a total of 49 such hernias have been reported in 17 case series. We present eight additional cases, three of which reoccurred after surgical correction, and review the current literature with a focus on recurrence. Materials and Methods The study sample included children (<18 years of age) who underwent LT between June 2013 and June 2020 at five large transplant centers and who subsequently presented with DH. During the study period, a total of 907 LT was performed. Eight DH were recognized, and ri…

medicine.medical_specialtyNauseamedicine.medical_treatment030230 surgeryLiver transplantationAsymptomatic03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRecurrencemedicineHumansDiaphragmatic herniaChildRetrospective StudiesSurgical repairHernia DiaphragmaticRespiratory distressbusiness.industryInfantmedicine.diseaseSurgeryLiver TransplantationChild PreschoolPediatrics Perinatology and Child HealthVomiting030211 gastroenterology & hepatologySurgerymedicine.symptombusinessComplicationEuropean journal of pediatric surgery : official journal of Austrian Association of Pediatric Surgery ... [et al] = Zeitschrift fur Kinderchirurgie
researchProduct

Neo-nervegenesis in 3D dynamic responsive implant for inguinal hernia repair. Qualitative study.

2020

Abstract Background Prosthetic repair of inguinal hernias is one of the most performed surgical procedures. Nevertheless, high rates of complications affect the surgical treatment. Implant fixation, poor-quality tissue ingrowth and mesh shrinkage seem to be involved in postoperative complications, discomfort and chronic pain following inguinal hernia repair. To address these issues a multilamellar shaped 3D dynamic responsive prosthesis has been developed. This new implant, positioned fixation-free to obliterate the hernia opening, thanks its inherent dynamic compliance during inguinal movements, has demonstrated to induce an enhanced biological response. The ingrowth of newly formed muscle…

medicine.medical_specialtyNeo-nervegenesimedicine.medical_treatmentConnective tissueArtificial LimbsHernia InguinalGroinProsthesisProsthesis Implantation03 medical and health sciences0302 clinical medicinePostoperative ComplicationsProstheseBiopsymedicineHumansHerniaTissue scaffoldsHerniorrhaphyQualitative ResearchGroinmedicine.diagnostic_testbusiness.industryInguinal herniaNerveGeneral MedicineSurgical Meshmedicine.diseaseHernia repairSurgerySettore MED/18 - Chirurgia GeneraleInguinal herniamedicine.anatomical_structure030220 oncology & carcinogenesisPrinting Three-DimensionalTissue regeneration030211 gastroenterology & hepatologySurgeryImplantbusinessInternational journal of surgery (London, England)
researchProduct

Tetralogy of Fallot as a Model to Study Cardiac Progenitor Cell Migration and Differentiation During Heart Development

2009

Tetralogy of Fallot (ToF) has long been considered a congenital disorder that occurs due to environmental alterations during gestation. Recently, several mutated genes have been discovered that are thought to be responsible for the malformations observed in ToF. These genetic mutations, which are microdeletions, are sporadic and are frequently also present in trisomy 21 patients. The ToF malformations can be lethal, but for the last 50 years, surgical repairs that place an artificial patch to repair the four features of ToF have improved the survival of patients with ToF. However, 0.5% to 6% of patients who survive after surgical repair of ToF die of sudden cardiac death caused by ventricul…

medicine.medical_specialtyOrganogenesisBiologyVentricular tachycardiaSudden cardiac deathHomeobox protein Nkx-2.5Cell MovementInternal medicinemedicineAnimalsHumansCell LineageCell ProliferationTetralogy of FallotHomeodomain ProteinsSurgical repairHeart developmentMyocardiumStem CellsGene Expression Regulation DevelopmentalCell DifferentiationToF Cardiac Stem Cellsmedicine.diseaseGATA4 Transcription Factormedicine.anatomical_structureVentricleMutationHomeobox Protein Nkx-2.5Tetralogy of FallotCardiologyCardiology and Cardiovascular MedicineTranscription FactorsCongenital disorderTrends in Cardiovascular Medicine
researchProduct

IF01. Collected Worldwide Experience From the PERICLES Registry With the Use of Chimney Grafts in the Treatment of Type I Endoleaks After Previous En…

2017

medicine.medical_specialtyPERICLESbusiness.industrymedicine.medical_treatmentPERICLES; chimney; endoleakendoleakSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairSurgeryMedicineSurgeryChimneyRadiologyCardiology and Cardiovascular MedicinebusinesschimneyJournal of Vascular Surgery
researchProduct

Oxidative Stress and DNA Damage in Human Gastric Carcinoma: 8-Oxo-7'8-dihydro-2'-deoxyguanosine (8-oxo-dG) as a Possible Tumor Marker

2013

We characterized the oxidative stress (OS) status by the levels of reduced/oxidized glutathione (GSH/GSSG), malondialdehyde (MDA) and the mutagenic base 8-oxo-7′8-dihydro-2′-deoxyguanosine (8-oxo-dG) in human gastric carcinoma (HGC) samples and compared the results with normal tissue from the same patients. We also analyzed 8-oxo-dG in peripheral mononuclear cells (PMNC) and urine from healthy control subjects and in affected patients in the basal state and one, three, six, nine and twelve months after tumor resection. The levels of DNA repair enzyme mRNA expression (hOGG1, RAD51, MUYTH and MTH1) were determined in tumor specimens and compared with normal mucosa. Tumor specimens exhibited i…

medicine.medical_specialtyPathologyDNA damageDNA repair8-oxo-dGBiologymedicine.disease_causePeripheral blood mononuclear cellArticleCatalysisInorganic Chemistrychemistry.chemical_compoundInternal medicinemedicine8-oxo-dG; DNA repair enzymes; gastric cancer; oxidative stress; tumor markeroxidative stressDeoxyguanosinePhysical and Theoretical ChemistryMolecular BiologySpectroscopyTumor markergastric cancerOrganic ChemistryGeneral MedicineGlutathioneMalondialdehydeComputer Science ApplicationsEndocrinologyDNA repair enzymeschemistrytumor markerOxidative stressInternational Journal of Molecular Sciences; Volume 14; Issue 2; Pages: 3467-3486
researchProduct

Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique

2018

Severe tricuspid regurgitation (TR) has long been neglected despite its well-known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though a device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and varia…

medicine.medical_specialtyPercutaneousProcedural approach610 Medicine & healthRegurgitation (circulation)030204 cardiovascular system & hematology2705 Cardiology and Cardiovascular Medicine03 medical and health sciences0302 clinical medicineMitral valveHumansMedicinecardiovascular diseases030212 general & internal medicineTRICUSPID VALVE REPAIRHeart Valve Prosthesis ImplantationTricuspid valvebusiness.industryPatient SelectionMitral Valve InsufficiencyTricuspid Valve InsufficiencyCardiac surgery10020 Clinic for Cardiac SurgeryTreatment Outcomemedicine.anatomical_structureEchocardiographycardiovascular systemTreatment strategyTricuspid ValveRadiologyCardiology and Cardiovascular Medicinebusiness
researchProduct

Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: A comparison of six diffe…

2012

Abstract Background An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. Methods New Zealand white rabbits were used for this study. Two meshes of the same brand (Ethicon Physiomesh™, Bard Composix ® L/P, Gore Dualmesh ® , Bard Sepramesh ® , Ethicon Proceed ® or Parietex™ Composite) were implanted into each animal for assessment of intra-abdominal hernia repair, with a total of ten meshes per group. Twelve weeks after implantation, the abdominal …

medicine.medical_specialtyPolyestersmedicine.medical_treatmentBiomedical EngineeringBiophysicsAdhesion (medicine)PolypropylenesDioxanesAbdominal wallAdhesivesMaterials TestingAnimalsMedicinePeritoneal CavityPhysiological reactionHerniorrhaphyMechanical PhenomenaWound HealingMathematical approximationbusiness.industryAbdominal WallIncisional hernia repairProstheses and ImplantsHernia repairmedicine.diseaseBiomechanical PhenomenaSurgeryCompliance (physiology)medicine.anatomical_structurePolydioxanoneRabbit modelFemaleRabbitsbusinessPorosityMedical Engineering & Physics
researchProduct

First-in-man permanent laparoscopic fixation free obliteration of inguinal hernia defect with the 3D dynamic responsive implant ProFlor-E®. Case repo…

2020

Abstract Introduction In the case of inguinal hernia recurrence after primary anterior repair, international guidelines strongly suggest a posterior laparoscopic approach. The 3D dynamic-responsive prosthesis for inguinal hernia repair ProFlor-E® has recently been introduced to the market. The present report describes the results of the first-in-man laparoscopic inguinal hernia repair carried out with ProFlor-E®. Presentation of case A 71-year-old male Caucasian presented with recurrent inguinal hernia after primary anterior repair. A fixation free TAPP procedure with ProFlor-E® was planned. Implant delivery and placement to obliterate the defect was quick and safe. Postoperatively, startin…

medicine.medical_specialtyRegenerative scaffoldmedicine.medical_treatmentCase ReportProFlor prosthesisProsthesisMesh fixation03 medical and health sciencesFixation (surgical)0302 clinical medicineLaparoscopicInguinal hernia repairMedicineHerniaDynamic responsivitybusiness.industryChronic painInvaginationmedicine.diseaseSurgeryInguinal herniaFixation free hernia repair030220 oncology & carcinogenesis030211 gastroenterology & hepatologySurgeryImplantbusinessInternational Journal of Surgery Case Reports
researchProduct

Progrip self-gripping mesh in Rives-Stoppa repair: Are there any differences in outcomes versus a retromuscular polypropylene mesh fixed with sutures…

2017

Highlights • The Rives-Stoppa technique is an excellent repair in midline incisional hernia. • Prospective comparative analysis between retromuscular Self-gripping mesh and PPL fixed with sutures. • Self-gripping mesh is related to less postoperative pain the first 48 h after repair. • There were more postoperative hematomas in Non-Progrip group. • There were no differences in hernia recurrence in both groups.

medicine.medical_specialtySelf-gripping meshIncisional hernia030230 surgery03 medical and health sciencesMesh repair0302 clinical medicineHematomamedicineCase SeriesRives techniqueIncisional herniabusiness.industryPostoperative complicationPerioperativemedicine.diseaseSurgerybody regionsPolypropylene meshsurgical procedures operative030220 oncology & carcinogenesisSeromaOperative timeSurgeryRives-Stoppa repairbusinessCase seriesInternational Journal of Surgery Case Reports
researchProduct