Search results for " Resolution"
showing 10 items of 1159 documents
A concept for a magnetic particle imaging scanner with Halbach arrays
2020
Magnetic particle imaging (MPI) is a new medical imaging technique visualizing the concentration distribution of superparamagnetic nanoparticles used as tracer material. MPI is not yet in clinical routine, since one of the challenges is the upscaling of scanners. Typically, the magnetic fields of MPI scanners are generated electromagnetically, resulting in an immense power consumption but providing high flexibility in terms of adjusting the field strengths and very fast image acquisition rates. Permanent magnets provide high flux densities and do not need any power supply. However, the flux density is not adjustable, and a mechanical movement is slow compared to electromagnetically varying …
A deep study of the high–energy transient sky
2021
This is an open access article. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds t…
Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)
2020
A High-Granularity Timing Detector (HGTD) is proposed based on the Low-Gain Avalanche Detector (LGAD) for the ATLAS experiment to satisfy the time resolution requirement for the up-coming High Luminosity at LHC (HL-LHC). We report on beam test results for two proto-types LGADs (BV60 and BV170) developed for the HGTD. Such modules were manufactured by the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences (CAS) collaborated with Novel Device Laboratory (NDL) of the Beijing Normal University. The beam tests were performed with 5 GeV electron beam at DESY. The timing performance of the LGADs was compared to a trigger counter consisting of a quartz bar coupled to a SiPM read…
Studies of plasma breakdown and electron heating on a 14 GHz ECR ion source through measurement of plasma bremsstrahlung
2011
Temporal evolution of plasma bremsstrahlung emitted by a 14?GHz electron cyclotron resonance ion source (ECRIS) operated in pulsed mode is presented in the energy range 1.5?400?keV with 100??s resolution. Such a high temporal resolution together with this energy range has never been measured before with an ECRIS. Data are presented as a function of microwave power, neutral gas pressure, magnetic field configuration and seed electron density. The saturation time of the bremsstrahlung count rate is almost independent of the photon energy up to 100?keV and exhibits similar characteristics with the neutral gas balance. The average photon energy during the plasma breakdown is significantly highe…
Asymmetric Homoaldol Reactions with Cyclohex-2-enylN,N-Diisopropylcarbamate: Kinetic Resolution, Elucidation of the Stereochemical Course and Applica…
2007
Enantio-enriched cyclohex-2-enyl N,N-diisopropylcarbamate (5) is stereospecifically deprotonated by sec-butyllithium/(–)-sparteine (9) to form the configurationally stable lithium complex 7·9. A kinetic resolution of rac-5 by n-butyllithium/(–)-sparteine (9) yielded (R)-5 with up to 99 % ee. Electrophilic substitution with tin electrophiles proceeds in a anti-SE′ fashion as shown by chemical correlations. The synthesized allylstannanes 10 undergo a highly stereospecific TiCl4-mediated homoaldol reaction with various aldehydes, yielding syn-configured homoaldol products 12. These were transferred into all-cis-configured hexahydroisobenzofuran-4(1H)-ones 22 by BF3·OEt2-mediated reactions with…
The Contingent Negative Variation – An Electrophysiological Correlate of Temporal Processing or Reference Memory?
2014
Abstract In EEG research, the contingent negative variation (CNV) is considered to be strongly related to interval timing (e.g., Macar & Vidal, 2004 ; Macar, Vidal, & Casini, 1999). However, it is discussed controversially whether certain properties of the CNV (e.g., amplitude, peak latency and resolution) directly reflect the process of temporal accumulation or rather processes related to reference memory or decision stages in temporal information processing (van Rijn et al., 2011). This present study was designed in order to investigate the relationship between CNV mean amplitude, CNV resolution, and memory processes as well as processes of temporal accumulation. The task design aimed at …
Approximating Empirical Surface Reflectance Data through Emulation: Opportunities for Synthetic Scene Generation
2019
Collection of spectroradiometric measurements with associated biophysical variables is an essential part of the development and validation of optical remote sensing vegetation products. However, their quality can only be assessed in the subsequent analysis, and often there is a need for collecting extra data, e.g., to fill in gaps. To generate empirical-like surface reflectance data of vegetated surfaces, we propose to exploit emulation, i.e., reconstruction of spectral measurements through statistical learning. We evaluated emulation against classical interpolation methods using an empirical field dataset with associated hyperspectral spaceborne CHRIS and airborne HyMap reflectance spectra…
Linear spectral mixture modelling to estimate vegetation amount from optical spectral data
1996
Abstract Spectral mixture modelling has developed in recent years as a suitable remote sensing tool for analysing the biophysical and compositional character of ground surfaces. In this paper the potentiality of the linear spectral mixture model to extract vegetation related parameters from 0·4-2·5 μm reflectance data has been tested. High spectral resolution reflectance measurements of soil-plant mixtures with different soil colour and plant densities were carried out in a laboratory experiment. The constrained least-squares and the factor analysis unmixing procedures were applied to generate endmember fractions of the components present in the mixtures and to test the validity of the mode…
Comparison of different sets of array configurations for multichannel 2D ERT acquisition
2017
Abstract Traditional electrode arrays such Wenner-Schlumberger or dipole-dipole are still widely used thanks to their well-known properties but the array configurations are generally not optimized for multi-channel resistivity measures. Synthetic datasets relating to four different arrays, dipole-dipole (DD), pole-dipole (PD), Wenner-Schlumberger (WS) and a modified version of multiple gradient (MG), have been made for a systematic comparison between 2D resistivity models and their inverted images. Different sets of array configurations generated from simple combinations of geometric parameters (potential dipole lengths and dipole separation factors) were tested with synthetic and field dat…
A DSP-Based Resolver-To-Digital Converter for High-Performance Electrical Drive Applications
2016
This paper presents a low cost, simple, and highly accurate resolver-to-digital converter (RDC) for electrical drive applications based on an integrated software approach, thus allowing a significant reduction of hardware components count with significant improvements in terms of reliability, reduction of fault rate, and susceptibility to electromagnetic interference (EMI). Particular attention has been addressed to cost which is 25% off over conventional RDC. Simulations and experimental tests confirm the high quality of the proposed system.