Search results for " Resolution"
showing 10 items of 1159 documents
Diffractive optics for high-resolution low-coherence digital holography
2010
We study the properties of the recording of off-axis holograms when a 10 fs pulsed laser is used as illumination source. A proper optical design involving one diffractive lens outside a Michelson interferometer enables the recording of full-field off-axis holograms with high resolution and optical sectioning. We demonstrate our approach with some experimental results that show optical sectioning with a maximum resolution of 3.5 µm. We note that the axial resolution of the technique is reduced up to 9 µm when the object beam travels through a few millimeters of glass due to the pulse broadening along dispersive media.
High resolution study of the 3ν1 band of SO2
2009
Abstract The second overtone band 3 ν 1 of sulfur dioxide has been studied for the first time with high resolution rotation-vibration spectroscopy. About 3000 transitions involving about 900 upper state energy levels with J max. = 66 and K a max. = 24 have been assigned to the 3 ν 1 band. In the analysis, an effective Hamiltonian taking into account accidental interactions between the vibrational states (3 0 0), (2 2 0), and (0 4 1) was used. The Watson operator in A -reduction and I r representation was used in the diagonal blocks of the Hamiltonian. As the result of analysis a set of parameters reproducing the initial experimental data with the rms = 0.00028 cm −1 was obtained.
Resistive Micromegas for the Muon Spectrometer Upgrade of the ATLAS Experiment
2017
It is reported on the construction and test of large scale resistive Micromegas detectors for the ATLAS New Small Wheel upgrade. The production procedure of the 2 to 3 m2 active area is described. The validation of the construction procedure is proven with results obtained with prototype detectors showing 100 µm spatial resolution in the precision coordinate and above 98% efficiency In the context of the upgrade project of the ATLAS Muon system, we report on the construction of Micromegas detectors with an active area of 2 to 3 m$^2$ . The validation of the construction procedure is proven with results obtained with prototype detectors showing 100 $\mu $m spatial resolution in the precision…
Stroboscopic XMCD-PEEM Imaging
2007
Abstract This article summarizes recent results on magnetization dynamics obtained with time-resolved photoemission electron microscopy (PEEM) using X-ray magnetic circular dichroism as contrast mechanism. Time resolution is performed by a stroboscopic technique that is exclusively sensitive to reversible processes, but offers a very high time resolution only limited by the X-ray pulse width. A time resolution of 20 ps in combination with a lateral resolution of 100 nm has been achieved.
DOI measurement with monolithic scintillation crystals: A primary performance evaluation
2007
We report a first assessment of image quality enhancement achieved by the implementation of depth of interaction detection with monolithic crystals. The method of interaction depth measurement is based on analogue computation of the standard deviation with an enhanced charge divider readout. This technique of depth of interaction detection was developed in order to provide fast and determination of this parameter at a reasonable increase of detector cost. The detector consists of an large-sized monolithic scintillator coupled to a position sensitive photomultiplier tube. A special design feature is the flat-topped pyramidal shape of the crystal. This reduces image compression near the edges…
2021
Abstract IceCube is a cubic-kilometer Cherenkov telescope operating at the South Pole. The main goal of IceCube is the detection of astrophysical neutrinos and the identification of their sources. High-energy muon neutrinos are observed via the secondary muons produced in charge current interactions with nuclei in the ice. Currently, the best performing muon track directional reconstruction is based on a maximum likelihood method using the arrival time distribution of Cherenkov photons registered by the experiment's photomultipliers. A known systematic shortcoming of the prevailing method is to assume a continuous energy loss along the muon track. However at energies >1 TeV the light yie…
Angular resolution of an array of tracking-chamber detectors for use in high-energy gamma-ray astronomy
1992
We describe a method of analysis for the reconstruction of the arrival direction of a high-energy photon impacting on the top of the atmosphere by using the directions of the particles on the shower front as measured by a ground-based array of tracking chambers uniformly distributed on a square surface; as an example, an array with enclosed surface of (120×120) m2 has been considered. Estimates on the accuracy of reconstruction are given, after application of the method to computer-simulated shower directions as a function of the number of «smapling» detectors and of their accuracy in the measurement of the «local» shower direction.
FIGARO IV: Large-area balloon-borne telescope to study rapid time variabilities in the gamma-ray sources at energies above 50 MeV
1993
We present a new γ-ray telescope based on the Limited Streamer Tube technology, used as tracking chambers to detect photons above 100 MeV. This technique allows to obtain very large sensitive areas (16 m2 in our experiment), together with a good angular resolution for payloads embarcable in high-altitude balloon flights. The capability to collect a large signal in a short exposure time makes the telescope particularly suitable and competitive with respect to satellite-based detectors for studying both periodic and random time variabilities on galactic and extragalactic γ-ray sources.
Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources
2004
In this study, complete dosimetric datasets for the CSM2 and CSM3 Cs-137 sources were obtained using the Monte Carlo GEANT4 code. The application of this calculation method was experimentally validated with thermoluminescent dosimetry (TLD). Functions and parameters following the TG43 formalism are presented: the dose rate constant, the radial dose functional, and the anisotropy function. In addition, to aid the quality control process on treatment planning systems, a two-dimensional (2D) rectangular dose rate table (the traditional along-away table), coherent with the TG43 dose calculation formalism, is given. The data given in this study complement existing information for both sources on…
MuPix7 - A fast monolithic HV-CMOS pixel chip for Mu3e
2016
The MuPix7 chip is a monolithic HV-CMOS pixel chip, thinned down to 50 \mu m. It provides continuous self-triggered, non-shuttered readout at rates up to 30 Mhits/chip of 3x3 mm^2 active area and a pixel size of 103x80 \mu m^2. The hit efficiency depends on the chosen working point. Settings with a power consumption of 300 mW/cm^2 allow for a hit efficiency >99.5%. A time resolution of 14.2 ns (Gaussian sigma) is achieved. Latest results from 2016 test beam campaigns are shown.