Search results for " Resolution"

showing 10 items of 1159 documents

Scaling and Noise in Slow Combustion of Paper

2000

We present results of high resolution experiments on kinetic roughening of slow combustion fronts in paper, focusing on short length and time scales. Using three different grades of paper, we find that the combustion fronts show apparent spatial and temporal multiscaling at short scales. The scaling exponents decrease as a function of the order of the corresponding correlation functions. The noise affecting the fronts reveals short range temporal and spatial correlations, and non-Gaussian noise amplitudes. Our results imply that the overall behavior of slow combustion fronts cannot be explained by standard theories of kinetic roughening. Peer reviewed

PhysicsPhysicspaperGeneral Physics and AstronomyHigh resolutionFunction (mathematics)Kinetic energyCombustionAmplitudeRange (statistics)Statistical physicskinetic rougheningScalingNoise (radio)Physical Review Letters
researchProduct

Simbol-X Mirror Module Thermal Shields: II-Small Angle X-Ray Scattering Measurements

2009

The formation flight configuration of the Simbol-X mission implies that the X-ray mirror module will be open to Space on both ends. In order to reduce the power required to maintain the thermal stability and, therefore, the high angular resolution of the shell optics, a thin foil thermal shield will cover the mirror module. Different options are presently being studied for the foil material of these shields. We report results of an experimental investigation conducted to verify that the scattering of X-rays, by interaction with the thin foil material of the thermal shield, will not significantly affect the performances of the telescope.

PhysicsPhysics::Instrumentation and DetectorsScatteringbusiness.industryShieldsX-ray bursts X-ray imaging Lenses prisms and mirrorsParticle detectorlaw.inventionTelescopeSettore FIS/05 - Astronomia E AstrofisicaOpticslawShieldAngular resolutionSmall-angle scatteringbusinessX- and gamma-ray telescopes and instrumentation X-ray scattering X-ray sourceFOIL methodAIP Conference Proceedings
researchProduct

Legri Operations. Detectors and Detector Stability

2001

Two years after launch (04.21.97), LEGRI is operating on Minisat-01 in a LEO orbit. The LEGRI detector plane is formed by two type of gamma-ray solid state detectors: HgI2 and CdZnTe. Detectors are embedded in a box containing the FEE and DFE electronics. This box provides an effective detector passive shielding. Detector plane is multiplexed by a Coded Aperture System located at 54 cm and a Ta Collimator with a FCFOV of 22° and 2° angular resolution. The aim of this paper is to summarize the detector behaviour in three different time scales: before launch, during the in-orbit check-out period (IOC), and after two years of routine operation in space. Main results can be summarized as follow…

PhysicsPhysics::Instrumentation and Detectorsbusiness.industryDetectorCollimatorMultiplexinglaw.inventionOpticslawElectromagnetic shieldingOrbit (dynamics)High Energy Physics::ExperimentAngular resolutionCoded apertureElectronicsbusiness
researchProduct

Software Timing Calibration of the ARGO-YBJ Detector

2009

The ARGO-YBJ experiment is mainly devoted to search for astronomical gamma sources. The arrival direction of air showers is reconstructed thanks to the times measured by the pixels of the detector. Therefore, the timing calibration of the detector pixels is crucial in order to get the best angular resolution and pointing accuracy. Because of the large number of pixels a hardware timing calibration is practically impossible. Therefore an off-line software calibration has been adopted. Here, the details of the procedure and the results are presented. (C) 2008 Elsevier B.V. All rights reserved.

PhysicsPixelCalibration (statistics)business.industryPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaDetectorSettore FIS/01 - Fisica SperimentaleComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONAstrophysics::Instrumentation and Methods for AstrophysicsAstronomy and AstrophysicsAstronomia gammaGamma Astronomy Timing Calibration Extensive Air ShowersSciami estesiCalibrazione temporaleOpticsSoftwareRaggi cosmiciSettore FIS/05 - Astronomia e AstrofisicaAngular resolutionbusinessArgoRemote sensing
researchProduct

First Compton imaging tests with i-TED

2019

The objective of this work is to demonstrate the Compton imaging capabilities of a novel gamma-ray Total-Energy Detector called i-TED. The latter is intended for neutron-capture cross-sections measurements of astrophysical interest, thereby enhancing detection sensitivity by means of the simultaneous combination of Time-of-Flight with Compton-imaging techniques. The developed i-TED demonstrator comprises five position-sensitive radiation detection modules of high energy resolution, which feature an overall position-sensitive field-of-view of 125 cm2, and thus a high efficiency. Each detector module is based on 50x50 mm2 large LaCl 3 (Ce) monolithic crystals optically coupled to 8x8 pixels s…

PhysicsPixelPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industryDetectorResolution (electron density)01 natural sciencesParticle detector030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSilicon photomultiplierOptics0103 physical sciencesAngular resolutionbusinessImage resolutionEnergy (signal processing)2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

A Pixelated Silicon Positron Sensitive Imaging Probe

2006

A pixelated silicon positron sensitive imaging probe is under development to precisely localize superficially located tumors accumulating 18F-FDG. 18F-FDG has been a radioisotope of interest mainly because of the high uptake in tumors and the relatively short positron range. Silicon detectors have generally low detection efficiency for high energy photons and can be used for positron detection. We present a pixelated silicon positron sensitive imaging probe that has the 1.4-by-1.4-by-1.0 mm pixel size with equivalent electronic noise of ~1.2 keV FWHM. The small pixel size leads to the high spatial resolution. Probe movement in conjunction with appropriate reconstruction will allow sub-pixel…

PhysicsPixelSiliconPhysics::Instrumentation and Detectorsbusiness.industryDetectorMonte Carlo methodResolution (electron density)chemistry.chemical_elementIterative reconstructionOpticsPositronchemistrybusinessNuclear medicineImage resolutionIEEE Nuclear Science Symposium Conference Record, 2005
researchProduct

Detailed diagnostics of an X-ray flare in the single giant HR 9024

2007

We analyze a 96 ks Chandra/HETGS observation of the single G-type giant HR 9024. The high flux allows us to examine spectral line and continuum diagnostics at high temporal resolution, to derive plasma parameters. A time-dependent 1D hydrodynamic model of a loop with half-length $L = 5 \times 10^{11}$ cm ($\sim R_{\star}/2$), cross-section radius $r = 4.3 \times 10^{10}$ cm, with a heat pulse of 15 ks and $2 \times 10^{11}$~erg cm$^{-2}$ s$^{-1}$ deposited at the loop footpoints, satisfactorily reproduces the observed evolution of temperature and emission measure, derived from the analysis of the strong continuum emission. For the first time we can compare predictions from the hydrodynamic …

PhysicsPlasma parametersAstrophysics::High Energy Astrophysical PhenomenaAstrophysics (astro-ph)Spectral propertiesX-rayFOS: Physical sciencesAstronomy and Astrophysicshydrodynamics plasmas stars: activityPlasmaAstrophysicsAstrophysicsSpectral linelaw.inventionHigh fluxSpace and Planetary SciencelawHigh temporal resolutionFlare
researchProduct

Random angular coding for superresolved imaging.

2010

In this paper, we present a new approach capable of working under coherent and incoherent illumination for achieving superresolution by random coding of the object's angular information. By placing two static random masks in optically conjugate planes inside an aperture-limited imaging setup, one may obtain a transmitted image containing spatial resolution higher than the one obtained without the masks. As the most noticeable fact, the superresolution effect is obtained without imposing any restrictions either in the time domain or in the field-of-view domain but rather only in the dynamic range of the camera device. Experimental verifications for the proposed technique with incoherent illu…

PhysicsPoint spread functionbusiness.industryDynamic rangeMaterials Science (miscellaneous)Aperture synthesisGhost imagingIndustrial and Manufacturing EngineeringNumerical aperturesymbols.namesakeOpticsFourier transformsymbolsTime domainBusiness and International ManagementbusinessImage resolutionApplied optics
researchProduct

Quasi-isotropic 3-D resolution in two-photon scanning microscopy.

2009

One of the main challenges in three-dimensional microscopy is to overcome the lack of isotropy of the spatial resolution, which results from the axially-elongated shape of the point spread function. Such anisotropy gives rise to images in which significant axially-oriented structures of the sample are not resolved. In this paper we achieve an important improvement in z resolution in two-photon excitation microscopy through spatial modulation of the incident beam. Specifically, we demonstrate that the design and implementation of a simple shaded ring performs quasi-isotropic three-dimensional imaging and that the corresponding loss in luminosity can be easily compensated by most available fe…

PhysicsPoint spread functionbusiness.industryIsotropyResolution (electron density)Physics::OpticsAtomic and Molecular Physics and OpticsOpticsTwo-photon excitation microscopyMicroscopyFemtosecondNear-field scanning optical microscopebusinessImage resolutionOptics express
researchProduct

Three-dimensional point spread function of multilayered flat lenses and its application to extreme subwavelength resolution

2011

The three-dimensional (3D) point spread function (PSF) of multilayered flat lenses was proposed in order to characterize the diffractive behavior of these subwavelength image formers. We computed the polarization-dependent scalar 3D PSF for a wide range of slab widths and for different dissipative metamaterials. In terms similar to the Rayleigh criterion we determined unambiguously the limit of resolution featuring this type of image-forming device. We investigated the significant reduction of the limit of resolution by increasing the number of layers, which may drop nearly 1 order of magnitude. However, this super-resolving effect is obtained in detriment of reducing the depth of field. Li…

PhysicsPoint spread functionbusiness.industryScalar (physics)Physics::OpticsMetamaterialCondensed Matter PhysicsElectronic Optical and Magnetic Materialssymbols.namesakeOpticsOptical transfer functionsymbolsDepth of fieldRayleigh scatteringbusinessImage resolutionOrder of magnitudeJournal of Nanophotonics
researchProduct