Search results for " Resolution"
showing 10 items of 1159 documents
Hyperfine transitions in the first overtone mode of hydrogen deuteride
2020
Beyond the metrology and computational challenges associated with molecular hydrogen, key data are expected to assess the physics of simple molecular systems, and even the new physics beyond the standard model. To assist the deciphering of Doppler-free spectra obtained at very high accuracy ($\ensuremath{\sim}{10}^{\ensuremath{-}9})$, we report on hyperfine transitions of HD in the lowest vibrational levels of the ground electronic state. Using the spin-rotation, nuclear spin-spin, and quadrupolar hyperfine couplings determined by means of high-level quantum-chemical calculations, the hyperfine energy levels and the associated line intensity have been obtained by using tensorial momentum al…
Resolution and field of view improvement in digital holography using a VCSEL source array
2011
We describe a new implementation capable to produce superresolution (SR) and object field of view (FOV) improvement in digital lensless Fourier holography. The method provides synthetic aperture (SA) generation using angular multiplexing incoming from a Vertical Cavity Surface Emitting Laser (VCSEL) source array. SR imaging in a single exposure is obtained after proper digital processing of a multiplexed hologram coming from the incoherent addition of multiple sub-holograms, each one corresponding with a different source of the VCSEL array. FOV improvement in addition with SR imaging is achieved by recording a set of individual holograms obtained by sequential activation of the VCSEL source…
Parallel Phase-Shifting Digital Holography Based on the Fractional Talbot Effect
2010
Digital holography allows us to record and process digitally the complex amplitude distribution associated to diffracted light beams and therefore has offered new possibilities for a variety of applications such as 3D microscopy, interferometry, or information security (see, for example, review [1]). In principle, phase-shifting techniques are the most efficient in terms of spatial resolution to record digital holograms [2]. However, a sequential acquisition of several interference patterns with different phase retardations of the reference beam is necessary, preventing dynamic measurements. Different techniques for time-resolved dynamic interferometry have been developed allowing one-shot …
Source linewidth effects in temporal imaging of Gaussian Schell-model pulses
2006
A transform-limited Gaussian pulse generated from an externally modulated stationary source is launched within a temporal imaging system composed of a second-order dispersion followed by a time lens and a subsequent quadratic dispersion. We consider the effect of the statistical properties of the emitted light for temporal imaging. In particular, it is shown that the design parameters that ensure a received signal with the minimum root-mean-square (rms) width achievable, which is called the temporal image of the incident pulse, are strongly dependent on the coherence properties of the input waveform. Finally, limitations on the temporal resolution of the setup are highlighted and a realisti…
The Intensities of Methane in the 3–5 μm Region Revisited
2001
The analysis of the linestrengths of the infrared spectrum of methane (12 and 13) in the 3-5 µm region has been revisited on the basis of new measurements from Fourier transform spectra recorded at Kitt Peak under various optical densities. A simultaneous fit of these new data with previously reported tunable difference-frequency laser data has been done. An effective transition moment model in tensorial form up to the third order of approximation within the Pentad scheme has been used. The standard deviations achieved are very close to the experimental precision: 3 and 1.5%, respectively, for the two sets of data for the (12)CH(4) molecule, representing a substantial improvement with respe…
Full field of view super-resolution imaging based on two static gratings and white light illumination.
2008
The usage of two static gratings for obtaining super-resolved imaging dates back to the work by Bachl and Lukosz in 1967. However, in their approach a severe reduction in the field of view was the necessary condition for improving the resolution. We present an approach based on two static gratings without sacrificing the field of view. The key idea for not paying with the field of view is to use white light illumination to average the ghost images obtained outside the region of interest since the positions of those images are wavelength dependent. Moreover, large magnification is achieved by using a commercial microscope objective instead of a test system with a unity magnification as prese…
IMAGINE: A Cold Neutron Imaging Station at the Laboratoire Léon Brillouin
2015
International audience; A second cold neutron imaging station has been open to users at the Laboratoire Léon Brillouin. The station is designed for high resolution neutron imaging and tomography. The typical field of view is 100x100 mm2 with a spatial resolution of 100 μm. Betterspatial resolutions (∼50 μm) can be achieved when reducing the field of view down to 30x30mm2. The L/D ratio can be varied from 200 to1000with pinhole sizes ranging from 20 to7 mm. Future upgrades will provide capabilities for energy resolved measurements using either a velocity selector or a double crystal monochromator. The possibility to perform polarized neutron experiments will also be provided next year.
Impact of slow gain dynamics on soliton molecules in mode-locked fiber lasers
2012
International audience; We theoretically demonstrate and experimentally confirm the major influence of gain dynamics on soliton molecules that self-assemble in mode-locked lasers. Both slow gain recovery and depletion play a pivotal role in the formation of chirped soliton molecules characterized by an increasing separation from leading to trailing pulses. These chirped molecules actually consist of many pulses and may be termed macromolecules. They are experimentally observed in a fiber laser and numerically modeled by an approach that properly includes the slow gain dynamics. Furthermore, it is shown that these processes stabilize soliton trains in fiber lasers by inhibiting internal osci…
Holographically aided iterative phase retrieval
2012
Fourier transform holography (FTH) is a noise-resistant imaging technique which allows for nanometer spatial resolution x-ray imaging, where the inclusion of a small reference scattering object provides the otherwise missing phase information. With FTH, one normally requires a considerable distance between the sample and the reference to ensure spatial separation of the reconstruction and its autocorrelation. We demonstrate however that this requirement can be omitted at the small cost of iteratively separating the reconstruction and autocorrelation. In doing so, the photon efficiency of FTH can be increased due to a smaller illumination area, and we show how the presence of the reference p…
SU-GG-T-70: A Dosimetric Study of the MicroSelectron HDR Ir-192 Brachytherapy Source
2010
Purpose: Recently the manufacturer of the mHDR‐v2 HDR Ir‐192 brachytherapy source clarified design changes that may alter the existing dosimetric data for this source. The object of this study was to obtain new dose rate tables following the TG‐43 formalism and to provide these data in close proximity to the source with high spatial resolution including the electron dosimetric contributions from Ir‐192 disintegration. Methods and Material: To study the source we used three different Monte Carlo codes: MCNP5, GEANT4, and Penelope. The source was located inside a 40 cm radius water phantom. Dose and kerma were obtained using 0.1 mm thick voxels to provide high‐resolution dosimetry near the so…