Search results for " Ring"
showing 10 items of 478 documents
First observation of the ground-state hyperfine transition in 209Bi80+
2013
The long sought after ground-state hyperfine transition in lithium-like bismuth 209Bi80+ was observed for the first time using laser spectroscopy on relativistic ions in the experimental storage ring at the GSI Helmholtz Centre in Darmstadt. Combined with the transition in the corresponding hydrogen-like ion 209Bi82+, it will allow extraction of the specific difference between the two transitions that is unaffected by the magnetic moment distribution in the nucleus and can therefore provide a better test of bound-state QED in extremely strong magnetic fields.
The storage ring magnet of the third muon (g-2) experiment at CERN
1978
The third ( g −2) experiment carried out at CERN required a storage ring magnet with a field as uniform as possible and known with an accuracy of a few parts per million over the whole storage region. Here we describe this magnet, which has a useful aperture of 120 mm horizontally and 80 mm vertically and a diameter of ∼14 m. The various field controls necessary are indicated, and the complex procedure adopted for the shimming work is described. The finally reached homogeneity of the field, averaged in azimuth, was 3 ppm. All the various error sources and field map corrections needed are analysed. Finally, the special aspects of the machine developed for the shimming are described.
The fifth order Peregrine breather and its eight-parameters deformations solutions of the NLS equation.
2013
We construct here explicitly new deformations of the Peregrine breather of order 5 with 8 real parameters. This gives new families of quasi-rational solutions of the NLS equation and thus one can describe in a more precise way the phenomena of appearance of multi rogue waves. With this method, we construct new patterns of different types of rogue waves. We get at the same time, the triangular configurations as well as rings isolated. Moreover, one sees appearing for certain values of the parameters, new configurations of concentric rings.
Toward a New Test of the Relativistic Time Dilation Factor by Laser Spectroscopy of Fast Ions in a Storage Ring
2003
The frequency measurement of Doppler-shifted optical lines of ions circulating in a storage ring at high speed permits a sensitive test of the relativistic Doppler-formula and, hence, the time dilation factor γSR of special relativity. Previous measurements at the storage ring TSR with 7Li+ at v = 0.065c gave a new, improved limit, but were hampered by the large observed linewidth, exceeding the natural width 15-fold. Recently we have identified the broadening to be caused by velocity-changing processes in the storage ring. Saturation spectroscopy has proven to be largely immune against these effects and has yielded linewidths only a few MHz larger than the natural one. This is the major in…
Measurement of polarization observables in elastic and inelastic electron-deuteron scattering at the VEPP-3 storage ring.
2001
Measurement of the transverse Doppler shift using a stored relativistic7Li+ ion beam
1992
We have performed for the first time precision spectroscopy on a coasting fast7Li+ ion beam in a storage ring. The ion beam moving with 6.4% speed of light was first electron cooled and then merged with two counterpropagating laser beams acting on two different hyperfine transitions sharing a common upper level (λ-system). One laser was frequency locked to thea 3 127J2 hfs frequency component established as a secondary frequency standard at 514 nm. The second laser was tuned over theλ-resonance, which was recorded relative to127J2 hfs components. This experiment is sensitive to the time dilation in fast moving frames and will lead to new limits for the verification of special relatively. Th…
Precision measurement of two iodine lines at 585 nm and 549 nm
1993
The transition frequencies of thei-component of the R(99)15-1 and thew-component of the R(85)26-0 transition in the B-X system of molecular127I2 have been determined with an overall relative standard uncertainty of 1.3 · 10−10. For this purpose a commercial linear dye laser has been modified and stabilized to the corresponding iodine line. This dye laser serves as a transportable frequency standard which is compared with the wavelength standards of the PTB. The evaluation of an experiment for testing special relativity at the test storage ring (TSR) in Heidelberg is based on the precision of the reported interferometric wavelength comparison.
The ARGO-YBJ experiment in Tibet
2008
The setting up of the ARGO detector at the YangBaJing Cosmic Ray Laboratory (4300 m a.s.l., Tibet, P.R. China) has been completed during the last spring (2007). It consists of a central carpet made of 130 identical sub-units of 12 RPCs each (a "cluster"), covering a surface of about 5800 m2 with 93% active area, and a guard ring of 24 further clusters of the same type surrounding the central carpet with a lower sampling density. Signals are picked up by external electrodes of small size, thus allowing the sampling of EAS with high space-time granularity. Shower events are detected at a trigger rate of about 4 kHz. Events with a few particles detected by a single cluster are counted in scale…
A linear radiofrequency quadrupole ion trap for the cooling and bunching of radioactive ion beams
2000
A linear radiofrequency quadrupole ion guide and beam buncher has been installed at the ISOLTRAP mass spectrometry experiment at the ISOLDE facility at CERN. The apparatus is being used as a beam cooling, accumulation, and bunching system. It operates with a buffer gas that cools the injected ions and converts the quasicontinuous 60- keV beam from the ISOLDE facility to 2.5-keV beam pulses with improved normalized transverse emittance. Recent measurements suggest a capture efficiency of the ion guide of up to 40% and a cooling and bunching efficiency of at least 12% which is expected to still be increased. The improved ISOLTRAP setup has so far been used very successfully in three on-line e…
Test of special relativity in an ion storage ring
1996
An accurate measurement of the Doppler effect in collinear laser spectroscopy has been performed at the TSR storage ring with electron cooled7Li+ ions atΒ=0.064. This experiment is a sensitive test of theγ=(1−Β2)−1/2 factor(Β=v/c) in the special theory of relativity. The Doppler shifted frequencies of the moving7Li+ ions are compared with calibrated molecular lines at rest. The frequencies at rest for the7Li+ ions are known from independent measurements. The Doppler shifted frequencies in the collinear experiment have been measured with a precision ofδv/v=6×10−9, mainly limited by the signal width of the resonance. A corresponding upper limit of 8×10−7 is deduced for any deviation of the ti…