Search results for " SCR"

showing 10 items of 1323 documents

Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept

2020

Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…

musculoskeletal diseasesSacrumMaterials sciencePercutaneousmedicine.medical_treatmentBone Screws0206 medical engineering02 engineering and technologyOsteotomyPelvisScrew fixationFracture Fixation InternalFractures Bone03 medical and health sciences0302 clinical medicineFragilitymedicineHumansOrthopedics and Sports MedicinePelvis030203 arthritis & rheumatologyOrthodonticsX-Raysequipment and suppliesmusculoskeletal systemSacrum020601 biomedical engineeringBiomechanical PhenomenaOsteotomyRadiographysurgical procedures operativemedicine.anatomical_structureSpinal FracturesStress MechanicalImplantTest protocolJournal of Orthopaedic Research
researchProduct

Muscleblind, BSF and TBPH are mislocalized in the muscle sarcomere of a Drosophila myotonic dystrophy model

2012

SummaryMyotonic dystrophy type 1 (DM1) is a genetic disease caused by the pathological expansion of a CTG trinucleotide repeat in the 3' UTR of the DMPK gene. In the DMPK transcripts, the CUG expansions sequester RNA-binding proteins into nuclear foci, including transcription factors and alternative splicing regulators such as MBNL1. MBNL1 sequestration has been associated with key features of DM1. However, the basis behind a number of molecular and histological alterations in DM1 remain unclear. To help identify new pathogenic components of the disease, we carried out a genetic screen using a Drosophila model of DM1 that expresses 480 interrupted CTG repeats, i(CTG)480, and a collection of…

musculoskeletal diseasesSarcomerescongenital hereditary and neonatal diseases and abnormalitiesNeuroscience (miscellaneous)lcsh:MedicineMedicine (miscellaneous)RNA-binding proteinGenes InsectBiologyMyotonic dystrophyGeneral Biochemistry Genetics and Molecular BiologyAnimals Genetically Modifiedchemistry.chemical_compoundImmunology and Microbiology (miscellaneous)RNA interferencelcsh:PathologymedicineMBNL1AnimalsDrosophila ProteinsHumansMyotonic DystrophyGeneticsMuscleslcsh:RAlternative splicingNuclear ProteinsRNA-Binding ProteinsEpistasis Geneticmedicine.diseaseDisease Models AnimalchemistryGene Knockdown TechniquesDrosophilaFemaleRNA InterferenceTrinucleotide repeat expansionTrinucleotide Repeat ExpansionDrosophila Proteinlcsh:RB1-214Genetic screenResearch ArticleDisease Models & Mechanisms
researchProduct

A new tool to improve pedicle screw placement accuracy in navigated spine surgery: A monocentric study

2021

Objective Navigated instrumented spine surgery is burden by a low but significant screw mispositioning risks, respectively, for the 2D imaging system from 15 to 40% and, for the 3D imaging system, ranging from 4.1 to 11.5%. The primary objective of this study was to demonstrate the efficacy of a new "screw-like" tool in order to further decrease pedicle screws mispositioning rate during vertebral navigated spine surgery. Materials and methods Between January and June 2019 an initial case series of 18 patients were enrolled. All patients underwent a pedicle screw fixation, both in thoracic (Th10-Th12) and lumbosacral (L1-S1) spine, using O-arm (Medtronic Navigation, Louisville, Colorado) and…

musculoskeletal diseasesmedicine.medical_specialty03 medical and health sciences0302 clinical medicineSpine surgeryImaging Three-DimensionalPedicle ScrewsMedicineHumansPedicle screw fixationPedicle screwNeuronavigationbusiness.industryNavigation systemmusculoskeletal systemSpineSurgerySurgery Computer-Assisted030220 oncology & carcinogenesisEquipment and suppliesSurgeryNeurosurgical proceduresNeurology (clinical)businessTomography X-Ray Computed030217 neurology & neurosurgeryLumbosacral joint
researchProduct

Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis

2015

In factures of the distal tibia with simple articular extension, the optimal surgical treatment remains debatable. In clinical practice, minimally invasive plate osteosynthesis and intramedullary nailing are both routinely performed. Comparative biomechanical studies of different types of osteosynthesis of intraarticular distal tibial fractures are missing due to the lack of an established model. The goal of this study was first to establish a biomechanical model and second to investigate, which are the biomechanical advantages of angle-stable plate osteosynthesis and intramedullary nailing of distal intraarticular tibial fractures. Seven 4(th) generation biomechanical composite tibiae feat…

musculoskeletal diseasesmedicine.medical_specialtyIntra-Articular Fracturesmedicine.medical_treatmentBone ScrewsTorsion MechanicalBone Nailsmedicine.disease_causeOsteotomyWeight-bearingBiomechanical Phenomenalaw.inventionWeight-BearingIntramedullary rodFixation (surgical)lawBone platemedicineHumansGeneral Environmental ScienceOrthodonticsOsteosynthesisbusiness.industrymusculoskeletal systemBiomechanical PhenomenaFracture Fixation IntramedullaryOsteotomySurgeryTibial FracturesFeasibility StudiesGeneral Earth and Planetary SciencesImplantbusinessBone PlatesInjury
researchProduct

Il trattamento chirurgico con vite cannulata e PRP della pseudoartrosi dello scafoide carpale

2013

Nonunion is an important complication of carpal navicular fractures. The aim of this study is to report the medium term results of a reconstruction technique with cannulated screw combined with Platelet Rich Plasma (PRP) in Herbert fractures C (late consolidation), D1 (fibrous union without deformity) and D2 (pseudarthrosis with initial deformity).

musculoskeletal diseasesmedicine.medical_specialtybusiness.industryNonunionGeneral Medicinemusculoskeletal systemmedicine.diseaseSurgeryMedium termnon union of the carpal navicular surgical treatment PRPPseudarthrosisPlatelet-rich plasmaSettore MED/33 - Malattie Apparato LocomotoremedicineDeformityCannulated screwmedicine.symptombusinessComplicationFibrous unionArchivio di Ortopedia e Reumatologia
researchProduct

Differences in Accuracy and Radiation Dose in Placement of Iliosacral Screws: Comparison between 3D and 2D Fluoroscopy

2022

Percutaneous iliosacral screw fixation is a widely accepted method of stabilizing the posterior pelvic ring. Recently developed tools such as 3D-navigated fluoroscopy and computed navigation seem to prevent a surgeon from conducting screw misplacement. The study aimed to comparatively assess the introduction of sacroiliac screw placement using 2D and 3D fluoroscopy in terms of accuracy and radiation exposure. Iliosacral screws were introduced in 37 patients using 2D (group N1) and in 36 patients using 3D fluoroscopy (group N2) techniques. Overall, 61 and 56 screws were introduced in groups N1 and N2, respectively. Screw placement accuracy was assessed using postoperative computed tomography…

musculoskeletal diseasessurgical procedures operativeiliosacral screw; 3D fluoroscopy; 2D fluoroscopy; pelvic ring injuries; percutaneous fixationGeneral Medicineequipment and suppliesmusculoskeletal systemJournal of Clinical Medicine
researchProduct

Computational studies of biomolecular screening and interactions

2015

negative image-based screeningseulontamolecular dockingliganditlääkeaineetvirtual screeninglaskennallinen kemiabiomolekyylitmolecular dynamicscomputational drug discoverylääkesuunnittelukemialliset sidoksetlääkekemiatietokannatproteiinitvirtuaaliseulontabinding free energy
researchProduct

Differences between current clinical guidelines for screening, diagnosis and management of non-alcoholic fatty liver disease and real-world practice:…

2021

International audience; INTRODUCTION: Nonalcoholic fatty liver disease (NAFLD) is the most common liver disease and is associated with obesity and metabolic comorbidities. Liver steatosis can progress to nonalcoholic steatohepatitis (NASH) exhibiting a relevant risk of fibrosis and ultimately liver failure. To date, no approved treatment for NASH to reduce its clinical and humanistic burden has been developed. AREAS COVERED: We undertook a literature review to identify English language, national and international clinical guidelines for NAFLD regarding diagnosis, assessment and management, and determined their points of agreement and difference. Additionally, we investigated published liter…

nonalcoholic fatty liver diseaseNonalcoholic steatohepatitismedicine.medical_specialtyliterature review[SDV]Life Sciences [q-bio]Liver fibrosisdigestive systemGastroenterologyDiagnosis DifferentialLiver diseasereal-world practiceLiver steatosisNon-alcoholic Fatty Liver DiseaseInternal medicineNonalcoholic fatty liver diseasemedicineHumansMass Screeningnonalcoholic steatohepatitisliver fibrosisHepatologybusiness.industryGastroenterologynutritional and metabolic diseasesfood and beveragesmedicine.diseaseObesitydigestive system diseases[SDV] Life Sciences [q-bio]clinical guidelinesPractice Guidelines as Topicbusiness
researchProduct

Per una riconsiderazione dello standard: un’indagine sull’italiano scritto degli studenti universitari di Palermo e Messina

2018

normacademic writingstandardSociologycontemporary Italianuse standarditaliano contemporaneonormaHumanitiesstandard contemporary Italian academic writing norm use standard italiano contemporaneo scrittura accademica norma usousoscrittura accademica
researchProduct

SYNTHESIS, REACTIVITY OF ISOINDOLE DERIVATIVES

2004

nucloephilic substitution electrophilic substitution antitumor compounds isoindole quinoxaline isoindole tetrazine antitumor screening
researchProduct