Search results for " Saturation"

showing 10 items of 177 documents

A Temperature Dependent Non-Linear Inductor Model for a DC/DC Boost Converter

2018

This paper is focused on the use of non-linear inductors in DC/DC switching converters, as well as their behaviour due to changes in current and temperature. The model of an inductor is set up on the basis of experimental data, which are automatically acquired by a virtual instrument; from those data, a polynomial curve describing the inductance variations is obtained. The analysis of the converter, performed by including the proposed model, is validated by experimental tests.

PhysicsPower inductorBasis (linear algebra)020209 energy020208 electrical & electronic engineeringExperimental data02 engineering and technologyConvertersInductorPower inductor modelling partial saturation roll-off region losses and temperature rise DC/DC converterSettore ING-INF/01 - Elettronicapartial saturationlossesInductanceSet (abstract data type)modellingNonlinear systemControl theoryDC/DC converterBoost converter0202 electrical engineering electronic engineering information engineeringrolloff region
researchProduct

Photoplethysmography in dogs and cats: a selection of alternative measurement sites for a pet monitor.

2018

Objective Photoplethysmography (PPG) is an increasingly popular health and well-being tool for monitoring heart rate and oxygen saturation. Due to the pigmentation and hairiness of dogs and cats, a pulse oximeter is routinely placed solely on the tongue. As this approach is feasible only for pet monitor use during surgical procedures, we investigate PPG signal quality on several other measurement sites that would be better tolerated by conscious animals. Approach Acquired PPG signals are analyzed by four signal quality indices: mean baseline, signal power, kurtosis, and tolerance score. Main results In dogs, the metacarpus and tail can be substituted for oral pulse oximeter placement since …

Physiology0206 medical engineeringBiomedical EngineeringBiophysics02 engineering and technologySignal03 medical and health sciences0302 clinical medicineDogsSignal qualityPhysiology (medical)PhotoplethysmogramHeart rateMedicineAnimalsPhotoplethysmographyOxygen saturation (medicine)CATSPulse (signal processing)business.industrySignal Processing Computer-AssistedPetsSurgical procedures020601 biomedical engineeringCatssense organsbusiness030217 neurology & neurosurgeryBiomedical engineeringPhysiological measurement
researchProduct

ERT and IPT surveys to check the integrity of the geomembrane in the landfill of Bellolampo (Palermo, Italy)

2016

In landfills, changes in resistivity and chargeability can be related to the characteristics of the waste and they can be abrupt and considerable within short distances. These physical properties are function of generation, mobility and degree of saturation of the leachate, gas generation, compaction density and variability. These relationships mean that it can be possible to get an overall image of the quantity and characteristics of the waste from surface electrical measurements over the landfill. In this paper, we present and discuss the results of three electrical tomographies carried out in the landfill site of Bellolampo (Palermo, Italy). The main aim of these surveys was to check the…

PollutionBellolampoHydrogeologyDegree of saturationmedia_common.quotation_subjectEngineering geologylandfillGeomembraneSettore GEO/11 - Geofisica ApplicataResistivity Induced ploarizationGeotechnical engineeringLeachateEconomic geologyGeologymedia_commonEnvironmental geology
researchProduct

An association between plasma ferritin concentrations measured 48 h after delivery and postpartum depression.

2010

Abstract Context Iron deficiency is the most common nutritional problem experienced by childbearing women, and postpartum depression (PPD) is the most common psychiatric disorder seen during the first year after delivery. The possible link between iron deficiency and PPD is not clear. Objective To evaluate whether iron status 48 h after delivery was associated with PPD. Our hypothesis was that iron deficiency would be associated with PPD. Design This was a prospective cohort study of depression-free women studied in the postpartum period. Setting Women who give birth at obstetric units in several general hospitals in Spain. Participants A subsample of 729 women was included in the present s…

Postpartum depressionAdultmedicine.medical_specialtyTime FactorsAnemiaContext (language use)Statistics NonparametricDepression PostpartummedicineHumansProspective Studieschemistry.chemical_classificationPsychiatric Status Rating ScalesChi-Square DistributionbiologyAnemia Iron-DeficiencyTransferrin saturationbusiness.industryObstetricsPostpartum PeriodIron deficiencymedicine.diseaseFerritinPsychiatry and Mental healthClinical PsychologyLogistic ModelschemistryTransferrinSpainImmunologyFerritinsbiology.proteinFemalebusinessPostpartum periodJournal of affective disorders
researchProduct

Characterization of inductors in partial saturation for SMPS applications

2017

The exploitation of partially saturated inductors in Switching Mode Power Supply (SMPS) is a key strategy for reducing the size of SMPS and increasing their power density [1]. However an accurate characterization and modellization of each inductor is needed for a correct design and control of the SMPS [2]. Most of inductors' datasheets only indicate the nominal inductance at low current. Anyway, when the inductor is subjected to a higher current, the value of the inductance is lessened. Moreover, inductance meters often actuate their measurements at no or moderate DC bias. In this work we describe the realization of an automated test bench (Fig. 1) for characterizing an inductor under varia…

Power ElectronicPartially saturated inductorDC/DC converterSwitching Mode Power SupplyBuck convertermodelinginductorSettore ING-INF/01 - Elettronicapartial saturationSMPS
researchProduct

Reticulocytes in untreated obstructive sleep apnoea.

2008

Background and Aim. The short, repetitive hypoxaemic episodes observed in obstructive sleep apnoea (OSA) may determine small augmentations in mature red blood cells. It is unknown whether they affect reticulocyte release. This study explored whether the number and degree of maturation of circulating reticulocytes may be altered in OSA, possibly through the effect of erythropoietin. Methods. Fifty male adult patients with suspected OSA, normoxic during wakefulness, were studied. After nocturnal polysomnography, a blood sample was withdrawn for blood cells count, erythropoietin, iron and transferrin determination. Reticulocyte concentration and degree of immaturity [high (H), medium (M), or l…

Pulmonary and Respiratory MedicineAdultMalemedicine.medical_specialtyPolysomnographylcsh:MedicineSettore MED/10 - Malattie Dell'Apparato RespiratorioSeverity of Illness IndexHaematopoiesis Nocturnal hypoxemia Obstructive sleep apnoea ErythropoietinCohort StudiesReticulocyteReticulocyte CountInternal medicinemedicineHumansErythropoiesisErythropoietinOxygen saturation (medicine)chemistry.chemical_classificationUnivariate analysisSleep Apnea ObstructiveTransferrin saturationbusiness.industryNocturnal hypoxemialcsh:RTransferrinMiddle Agedrespiratory tract diseasesHaematopoiesisEndocrinologymedicine.anatomical_structureHaematopoiesischemistryErythropoietinTransferrinObstructive sleep apnoeaWakefulnessCardiology and Cardiovascular Medicinebusinessmedicine.drug
researchProduct

Observation of ventilation-induced Spo(2) oscillations in pigs: first step to noninvasive detection of cyclic recruitment of atelectasis?

2010

High arterial partial oxygen pressure (Pao(2)) oscillations within the respiratory cycle were described recently in experimental acute lung injury. This phenomenon has been related to cyclic recruitment of atelectasis and varying pulmonary shunt fractions. Noninvasive detection of Spo(2) (oxygen saturation measured by pulse oximetry) as an indicator of cyclic collapse of atelectasis, instead of recording Pao(2) oscillations, could be of clinical interest in critical care. Spo(2) oscillations were recorded continuously in three different cases of lung damage to demonstrate the technical feasibility of this approach. To deduce Pao(2) from Spo(2), a mathematical model of the hemoglobin dissoci…

Pulmonary and Respiratory MedicinePulmonary AtelectasisPulmonary CirculationTime FactorsVentilator-associated lung injurySwineClinical BiochemistryAtelectasisLung injuryModels BiologicalHemoglobinsPredictive Value of TestsMedicineAnimalsOximetryPhotoplethysmographyMolecular BiologyOxygen saturation (medicine)Respiratory Distress Syndromemedicine.diagnostic_testbusiness.industryfungiOxygen–haemoglobin dissociation curveOxygenationmedicine.diseaseRespiration ArtificialOxygenPulse oximetryDisease Models AnimalAnesthesiaBreathingRespiratory MechanicsFeasibility StudiesbusinessExperimental lung research
researchProduct

Target oxygen levels in preterm neonates

2013

To achieve postnatal adaptation newly born infant need to aerate the lungs, reduce pulmonary vascular resistance, and initiate oxygen and carbon dioxide exchange. The cornerstone of newborn resuscitation resides therefore in the establishment of a functional residual capacity and an adequate oxygenation. Recent guidelines have established guidelines concerning oxygen supplementation in preterm infants in the delivery room (DR); however, they are vague and unspecific. Herewith, we will address available information regarding the use of oxygen supplementation in the DR in preterm infants to satisfactorily overcome postnatal adaptation. Introduction: Resuscitation of the newborn is considered …

Pulmonary and Respiratory MedicineResuscitationFetusmedicine.diagnostic_testbusiness.industryRetinopathy of prematuritymedicine.diseasePulmonary hypertensionPulse oximetryBronchopulmonary dysplasiaAnesthesiaHypoxic pulmonary vasoconstrictionPediatrics Perinatology and Child HealthmedicinebusinessOxygen saturation (medicine)Paediatric Respiratory Reviews
researchProduct

Comment to the Editorial by KS Park and EW Kang “Is only fixed positive airway pressure a robust tool for kidney protection in patients with obstruct…

2019

We thank doctors Park and Kang for their editorial that well summarized our article. Our common belief is that one of the possible consequences of untreated obstructive sleep apnea (OSA) is an accelerated deterioration of kidney function, and that more knowledge would be necessary on the possible protective effects of OSA treatments. To our knowledge, so far the only OSA therapy whose effects on renal function have been tested is continuous positive airway pressure (CPAP), and most , although not all studies, have demonstrated its benefits. Our own study, while confirming benefits of fixed CPAP, has demonstrated little effect of auto-adjusting CPAP (APAP). This finding may be of relevance a…

Pulmonary and Respiratory Medicinemedicine.medical_specialtyLetterestimated glomerular filtration ratekidney diseaseRenal functionPolysomnographySettore MED/10 - Malattie Dell'Apparato Respiratoriosleep disordered breathingpolysomnographyrenal protectionPositive airway pressureMedicineIn patienthumansleepIntensive care medicinekidney functionLetter to the EditorPositive end-expiratory pressureKidneymedicine.diagnostic_testbusiness.industryobstructive sleep apnea ; kidney protection ; fixed positive airway pressuremedicine.diseaseoxygen saturationrespiratory tract diseasesObstructive sleep apneaNot availablemedicine.anatomical_structureEditorialpositive end expiratory pressureHuman medicinebusinesschronic obstructive lung diseaseKidney disease
researchProduct

Dynamic determination of oxygenation and lung compliance in murine pneumonectomy.

2011

Thoracic surgical procedures in mice have been applied to a wide range of investigations, but little is known about the murine physiologic response to pulmonary surgery. Using continuous arterial oximetry monitoring and the FlexiVent murine ventilator, the authors investigated the effect of anesthesia and pneumonectomy on mouse oxygen saturation and lung mechanics. Sedation resulted in a dose-dependent decline of oxygen saturation that ranged from 55% to 82%. Oxygen saturation was restored by mechanical ventilation with increased rate and tidal volumes. In the mouse strain studied, optimal ventilatory rates were a rate of 200/minute and a tidal volume of 10 mL/kg. Sustained inflation pressu…

Pulmonary and Respiratory Medicinemedicine.medical_treatmentClinical BiochemistryPulmonary complianceArticlePositive-Pressure RespirationPneumonectomyMiceTidal VolumeMedicineAnimalsLung volumesAnesthesiaPneumonectomyMolecular BiologyLungLung ComplianceTidal volumeOxygen saturation (medicine)Mechanical ventilationLungbusiness.industryTotal Lung CapacityOxygenationrespiratory systemRespiration ArtificialMice Inbred C57BLOxygenmedicine.anatomical_structureAnesthesiabusinessLung Volume MeasurementsExperimental lung research
researchProduct