Search results for " Scanning"
showing 10 items of 988 documents
Solubilization of an Organic Solute in Aqueous Solutions of Unimeric Block Copolymers and Their Mixtures with Monomeric Surfactant: Volume, Surface T…
2008
The ability of aqueous systems, formed by unimeric copolymers and their mixtures with a monomeric surfactant, in solubilizing large quantities of 1-nitropropane (PrNO2) was explored. The copolymers are F68 and L64, which differ for the hydrophilicity, and the surfactant is sodium dodecanoate. For a better understanding of the mechanism of solubilization, thermodynamic (volume and differential scanning calorimetry), spectroscopy (steady-state fluorescence), viscosity, and interfacial investigations were carried out. PrNO2 causes the micellization of the unimeric copolymer, and the required amount of PrNO2 depends on the composition, the copolymer nature, and the temperature. Large quantities…
Microheterogeneous electrocatalytic chiral recognition at monoclinic vanadium-doped zirconias: enantioselective detection of glucose.
2007
Synthetic tetragonal and monoclinic vanadium-doped zirconias (t- and m-VxZr1-xO2, 0.005x0.150) exert an effective catalytic effect toward the electrochemical oxidation of glucose in aqueous alkaline media. The catalytic effect of monoclinic specimens attached to carbon and fluorine-doped tin oxide electrodes exhibits a remarkable enantioselectivity, so that catalytic currents for the oxidation of L-glucose at +0.92 V vs AgCl/Ag are considerably larger than those obtained for the oxidation of D-glucose. This enantioselectivity can be associated with the existence of a noncentrosymmetric coordination of vanadium centers in the monoclinic crystalline form of zirconia. From the electrochemical …
Novel water-swellable beads based on an acryloylated polyaspartamide
2001
Spherical polymeric microparticles have been prepared by a reverse-phase suspension polymerization technique. The starting polymer was α,β-poly (N-2-hydroxyethyl)-dl-aspartamide (PHEA) partially functionalised with glycidylmethacrylate (GMA) in order to introduce reactive vinyl groups in the side chain. The PHEA–GMA copolymer obtained (PHG) was cross-linked in a mixture of water/hexane–carbon tetrachloride in the presence of sorbitan trioleate (Span 85) as surfactant and ammonium persulfate/N,N,N′,N′-tetramethylethylenediamine as initiator system. The reaction was also carried out in the presence of N,N′-dimethylacrylamide as comonomer or N,N′-ethylenebisacrylamide as a cross-linking agent.…
Levantamiento del templo G. parque arqueologico de Selinunte, Trapani. Sicilia. Informe general
2006
El trabajo de campo al que se refiere la presente comunicación, se puede considerar como la fase inicial del proyecto de levantamiento del templo G de Selinunte, ya que si bien se han podido tomar muchos datos del mismo durante la campaña de verano del 2005, quedan algunas zonas donde no ha sido posible acceder, por lo que será preciso completar la información conforme se vaya avanzando en el modelo. La dificultad mayor vendrá con la definición del propio modelo 3D, labor de investigación avanzada ya que actualmente no existen técnicas ni metodologías de referencia a nivel mundial en el uso de escaners láser 3d aplicados al campo de la arquitectura. Esta segunda tarea la estamos llevando a …
Integrated use of unmanned aerial vehicle photogrammetry and terrestrial laser scanning to support archaeological analysis: The Acropolis of Selinunt…
2021
Southwestern Sicily is an area of infrequent seismic activity; however, some studies carried out in the archaeological Selinunte site suggest that, between the fourth century BC and the early Middle Ages, probably at least two earthquakes strucked this area with enough energy to damage and cause the collapse and kinematics of much of the architecture of Selinunte. Take into account that, in 2008, a noninvasive archaeological prospection and traditional data gathering methods along the Acropolis north fortifications were carried out. Following these first studies, after about 10 years, a new geophysical campaign was carried out. This second campaign benefited from the application of modern t…
Increasing contextual information by merging existing archaeological data with state of the art laser scanning in the prehistoric funerary deposit of…
2013
Abstract In this paper we present a virtual reconstruction of prehistoric funerary practices in Pastora Cave, a collective burial site in Eastern Spain that dates from the Late Neolithic, Chalcolithic and Bronze Age. Modern data of the cave was captured by 3D laser scanning techniques and added to recorded archaeological data and 3D graphic information. The combination of these data sets allowed us to create a hypothetical reconstruction to analyze the material excavated in the 1940s and 50s in greater spatial context. A 3D model of the current cave was created in order to serve as a basis for modeling the relative stratigraphic information available. We present the methodology employed and…
Using mechanical experiments to study ground stone tool use: Exploring the formation of percussive and grinding wear traces on limestone tools
2021
Ground Stone Tools (GST) have been identified in several Levantine archaeological sites dating to the Middle Paleolithic. These tools, frequently made of limestone, are often interpreted based on their morphology and damage as having been used for knapping flint, and sometimes for breaking animal bones or processing vegetal materials as well. However, the lack of experimental referential collections on limestone is a major obstacle for the identification of diagnostic traces on these types of tools and raw material. In this sense, the understanding of the specific function of these GST and the association between tool types and activity often remains unknown or merely speculative. Recent di…
Terrestrial laser scanning and close range photogrammetry for 3D archaeological documentation: the Upper Palaeolithic Cave of Parpalló as a case study
2010
Graphic and metric archaeological documentation is an activity that requires the capture of information from different sources, accurate processing and comprehensive analysis. If monitoring of the state of conservation is required, this task has to be performed before intervention, during and after the completion of the works in a repetitive way. This paper presents the use of terrestrial laser scanning (TLS) in order to effectively produce, prior to intervention, accurate and high-resolution 3D models of a cave with engravings dating back to the Upper Palaeolithic era. The processing of the TLS data is discussed in detail in order to create digital surface models. The complexity of the cav…
Cure kinetics of a cobalt catalysed dicyanate ester monomer in air and argon atmospheres from DSC data
2004
A kinetic analysis of the cyclotrimerisation reaction of a dicyanate ester monomer catalysed by cobalt(II) acetylacetonate and nonylphenol in air and argon atmospheres has been carried out by differential scanning calorimetry (DSC). Dynamic and isothermal DSC scans as well as the glass transition temperature are the experimental data obtained. From isothermal scans a higher cyanate conversion in air than in argon was obtained. The cyanate conversions are satisfactorily described with a second-order kinetic equation in the kinetically controlled region, and by m-order (m<1) equation after vitrification is reached. Activation energies determined by different procedures agree among them, showi…
Determination of the glass transition temperature of poly(cyclohexyl acrylate) from oxygen permeability measurements
1993
Abstract The glass transition temperature ( T g ) of poly(cyclohexyl acrylate) (PCA) has been obtained from measurements of the oxygen permeability ( P = 0.60 barrers, T g = 23.5 ± 2.0°C) using a potentiostatic electrochemical sensor, and from the oxygen diffusion coefficient ( D = 0.12 × 10 −8 cm 2 s −1 , T g = 24.0 ± 1.8°C) by the time-lag method. A T g of 25 ± 1°C was found by differential scanning calorimetry and a T g of 25.0 ± 3.5°C was obtained from the specific volume by dilatometry. The fractional free volume ( v f ) at T g is 0.020 ± 0.002, which is slightly below (∼ 20%) most glassy polymers. A linear correlation has been observed between ln D and the reciprocal of v f , which su…