Search results for " Self"

showing 10 items of 981 documents

Flash glucose monitoring reduces glycemic variability and hypoglycemia: real-world data from Spain.

2020

ObjectiveObservations in real-world settings support and extend findings demonstrated in randomized controlled trials that show flash glucose monitoring improves glycemic control. In this study, Spain-specific relationships between testing frequency and glycemic parameters were investigated under real-world settings.Research design and methodsDeidentified glucose and user scanning data were analyzed and readers were rank ordered into 20 equal sized groups by daily scan frequency. Glucose parameters were calculated for each group: estimated HbA1c, time below range (<70 and ≤54 mg/dL), within range (70–180 mg/dL), and above range (>180 mg/dL). Glycemic variability (GV) metrics were desc…

Blood Glucosemedicine.medical_specialtyEndocrinology Diabetes and Metabolism030209 endocrinology & metabolismHypoglycemialaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawInternal medicineDiabetes mellitusmedicineHumans030212 general & internal medicine1506GlycemicBlood glucose monitoringmedicine.diagnostic_testbusiness.industryBlood Glucose Self-MonitoringEmerging Technologies Pharmacology and Therapeuticsmedicine.diseaseDiabetes Mellitus Type 1GlucosehypoglycemiaSpainCardiologyglycemic controlblood glucose monitoringbusinessReal world dataBMJ open diabetes researchcare
researchProduct

Glycemic Variability Assessment with a 14-Day Continuous Glucose Monitoring System: When and How Long to Measure MAGE (Mean Amplitude of Glucose Excu…

2021

Mean amplitude of glucose excursion (MAGE) is considered as the “gold standard” for assessing the short-term within-day glycemic variability (GV), which is an important component of overall glycemic control. A 14-day continuous glucose monitoring system is now widely used and allows easier assessment of GV. However, it is still unknown whether MAGE, usually calculated on a 48-hour period is identical whatever the time during the 14-day lifespan of the sensor and whether a longer time period might give additional information. We evaluated in 68 patients with type 1 diabetes, MAGE during three 2-day periods (day1-day3; day6-day8; day11-day13) and during periods of 3 days and 4 days. MAGE cal…

Blood Glucosemedicine.medical_specialtyEndocrinology Diabetes and MetabolismBiomedical Engineering030209 endocrinology & metabolismBioengineering030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineInternal medicineTechnology ReportsInternal MedicinemedicineHumansReliability (statistics)GlycemicType 1 diabetesContinuous glucose monitoringbusiness.industryBlood Glucose Self-MonitoringReproducibility of ResultsGold standard (test)Glucose excursionmedicine.diseaseGlucoseAmplitudeDiabetes Mellitus Type 2CardiologybusinessJournal of Diabetes Science and Technology
researchProduct

Time-in-range for monitoring glucose control: Is it time for a change?

2021

The HbA1c value has been the gold standard for evaluating glucose control for decades. However, it has limitations such as the lack of information on glycemic variability or the risk of hypoglycemia. The increasing use of continuous glucose monitoring has provided patients and healthcare professionals with a range of useful metrics for the management of diabetes. Among them, Time in Range (TIR) is a simple and intuitive metric that gives information regarding the quality of glucose control. It is defined as the time spent in an individual's target glucose range. TIR is strongly correlated with HbA1c, and it has been linked to the risk of developing microvascular and macrovascular complicati…

Blood Glucosemedicine.medical_specialtyEndocrinology Diabetes and MetabolismControl (management)030209 endocrinology & metabolismType 2 diabetesHypoglycemia03 medical and health sciences0302 clinical medicineEndocrinologyDiabetes mellitusInternal MedicinemedicineRange (statistics)Humans030212 general & internal medicineGlycemicbusiness.industryBlood Glucose Self-MonitoringGeneral MedicineGold standard (test)medicine.diseaseHypoglycemiaDiabetes Mellitus Type 1Diabetes Mellitus Type 2Emergency medicineMetric (unit)businessDiabetes research and clinical practice
researchProduct

Psychosocial Aspects of Continuous Glucose Monitoring

2016

Continuous glucose monitoring (CGM) systems provide people with diabetes with valuable real-time information on glucose trajectories and trends, thus offering opportunities for improving diabetes self-management. Ample evidence from clinical trials underscores CGM effectiveness for biomedical outcomes including HbA1C and hypoglycemia. However, interindividual variability in CGM uptake seems to be substantial: Neither do all individuals with diabetes adopt CGM readily in their diabetes self-management, nor do all of them benefit from CGM. In this article, we focus on CGM effects on quality of life and the potential role of psychosocial patient characteristics for determining the uptake and …

Blood Glucosemedicine.medical_specialtyendocrine system diseasesEndocrinology Diabetes and MetabolismBiomedical EngineeringPatient characteristics030209 endocrinology & metabolismBioengineeringHypoglycemia03 medical and health sciences0302 clinical medicineQuality of life (healthcare)Diabetes mellitusDiabetes MellitusInternal MedicinemedicineHumans030212 general & internal medicineSpecial Section: Psychological Factors for Diabetes Technology Part IIIntensive care medicineContinuous glucose monitoringbusiness.industryBlood Glucose Self-Monitoringnutritional and metabolic diseasesmedicine.diseaseClinical diabetesClinical trialQuality of LifebusinessPsychosocialJournal of Diabetes Science and Technology
researchProduct

Ambulatory Glucose Profile Applied to Flash Glucose Monitoring in Real Life: An Expert Opinion.

2016

The clinical benefits of real time continuous glucose monitoring (rtCGM) use have been well demonstrated in both CSII- and MDI-treated individuals in large clinical trials. However, recommendations for patient use of rtCGM in everyday life situations are lacking. This article provides guidance to clinicians and patients with type 1 diabetes (T1D) in effective use of rtCGM data, including glucose rate of change (ROC) arrows, for insulin dosing adjustments and other treatment decisions. The recommendations presented here are based on our own clinical experiences as endocrinologists, our personal experiences living with T1D using rtCGM, and findings from a recent survey of T1D patients who hav…

Blood Glucosemedicine.medical_specialtymultiple daily insulin injectionstype 1 diabetesEndocrinology Diabetes and MetabolismMonitoring ambulatoryBiomedical Engineeringflash glucose monitoringrate of changeMonitoring Ambulatory030209 endocrinology & metabolismBioengineeringglucose-monitoring systemMDI03 medical and health sciencesFlash (photography)0302 clinical medicineDiabetes mellitusBlood Glucose Self-MonitoringmedicineInternal MedicineIn real lifeambulatory glucose profile; diabetes; flash glucose monitoring; glucose-monitoring systems; glycemic control030212 general & internal medicineglucose-monitoring systemsIntensive care medicineambulatory glucose profileExpert TestimonyReview Articlesdiabetesbusiness.industryMedicine (all)Blood Glucose Self-MonitoringCSIImedicine.diseaseDiabetes Mellitus Type 1GlucosediabeteExpert opinioninsulin pumpAmbulatoryglucose profileglycemic controlcontinuous glucose monitoringMedical emergencybusinessJournal of diabetes science and technology
researchProduct

Self-blood pressure monitoring as a tool to increase hypertension awareness, adherence to antihypertensive therapy, and blood pressure control

2019

For many years, casual blood pressure (BP) taken by a sphygmomanometer in the clinic or at the physician's office has been used as the standard method for diagnosing hypertension. Even if such measurement has been the cornerstone on which our understanding of the consequences of hypertension is based, there is a huge and very consistent body of evidence indicating that casual measurements of BP may provide a very unreliable index for the evaluation of hypertension because of their variability. The two alternative ways of measuring BP that have been most commonly used are measurements made at home by the patient himself (home or self‐BP monitoring—SBPM) and measurements by ambulatory blood p…

Blood pressure controlmedicine.medical_specialtybusiness.industryEndocrinology Diabetes and MetabolismMEDLINEHome blood pressure - Self blood pressure measurement - Blood pressure controlAmbulatoryEmergency medicineInternal MedicinemedicineBlood pressure monitoringCardiology and Cardiovascular MedicineProspective cohort studybusiness
researchProduct

Multilayered cultural identity and the perception of the self

2012

This qualitative study examines the reciprocal relationship between a person’s multilayered cultural identity (MCI) and the concept of self (CoS), that is presented purely on a theoretical level and encompasses various theories. Nowadays, in an increasingly globalising world, it is not enough to merely look at a national, ethnic or other type of identity. It is important to realise that there are different layers in an identity that one can view themselves through. The ways an individual perceives themselves through their multicultural background can also be different. This thesis helps identify the ways a person can see themselves. The thesis also attempts to explain the varied nature of o…

Bodily SelfComplex IdentityitseSelf-identityIdentity FlexibilitySelfKvalitatiivinen tutkimusitsetuntoSelf-esteemIdentity Politics.Multilayered or Multifaceted Cultural IdentityidentiteettiSelf-perceptionkulttuuri-identiteettiminä
researchProduct

Addressing Student Motivation, Self-regulation, and Engagement in Flipped Classroom to Decrease Boredom

2016

The interplay teacher regulation and student self- regulation of learning is an important topic in contemporary theories of teaching and learning. The pervasiveness of the boredom experienced by many students, along with its deleterious effects, clearly implies that educators, and teachers responsible for the design of academic settings should pay more attention to this emotion. With regard to the prevention or reduction of boredom, the present findings suggest that specific measures could focus on increasing the perceived values of activities in achievement settings. This study used mixed methodologies, including a student perception inventory and observations, to investigate whether teach…

Boredom flipped observations of teacher practices self-regulation.05 social sciences050301 educationStudent engagementBoredomFlipped classroom050105 experimental psychologyComputer Science ApplicationsEducationPedagogymedicine0501 psychology and cognitive sciencesmedicine.symptomPsychology0503 educationSettore M-PED/03 - Didattica E Pedagogia SpecialeInternational Journal of Information and Education Technology
researchProduct

Validation of Teacher Self-efficacy (QAI) Questionnaire

2021

Negli ultimi anni numerose ricerche nazionali e internazionali hanno messo in evidenza l’importanza della Teacher Self Efficacy. Nonostante nel panorama nazionale esistano già alcuni strumenti che indagano tale costrutto, si notano sovrapposizioni e divergenze nei diversi fattori presi in considerazione, quali ad esempio la percezione di autoefficacia relativa alla possibilità di agire sull’engagement degli studenti e sulla colla- borazione con la famiglia e altre figure professionali. Pertanto l’obiettivo del presente contributo consiste nella costruzione e validazione di un nuovo strumento che tenga conto di entrambi quest’ultimi aspetti. Lo strumento, costituito da 25 item, è stato so…

CFASelf-Report evaluationEFAValutazione Self-ReportvalidazioneValidationTeacher Self-Efficacy; Validation; EFA; CFA; Self-Report evaluationTeacher Self-EfficacyAutoefficacia dei docentiSettore M-PED/03 - Didattica E Pedagogia Speciale
researchProduct

Molecular Self-Assembly Versus Surface Restructuring During Calcite Dissolution.

2016

Organic additives are known to alter the mineral-water interface in various ways. On the one hand, organic molecules can self assemble into ordered structures wetting the surface. On the other hand, their presence can affect the interfacial morphology, referred to as surface restructuring. Here, we investigate the impact, of a class of calcium-complexing azo dyes on the dissolution of calcite (10.4) using high-resolution atomic force microscopy operated in aqueous solution, with a focus on the two constitutional isomers Eriochrome Black T and Eriochrome Black A. A very pronounced surface restructuring is observed in the presence of the dye solution, irrespective of the specific dye used and…

CalciteAqueous solutionMorphology (linguistics)Chemistry02 engineering and technologySurfaces and Interfaces010402 general chemistry021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciences5300104 chemical sciencesEriochrome Black Tchemistry.chemical_compoundChemical engineeringElectrochemistryMolecular self-assemblyOrganic chemistryMoleculeGeneral Materials ScienceWetting0210 nano-technologyDissolutionSpectroscopyLangmuir : the ACS journal of surfaces and colloids
researchProduct