Search results for " Sensor"
showing 10 items of 1714 documents
Adaptation of two-state (binary) optical fibre loop sensors for industrial use
2005
The paper presents an attempt to unify the construction of two state optical fibre loop sensor and possibility of adapting it to the various traditional constructions and casings of industrial sensors. This enables module structure of sensors based on construction of industrial application (master) and mensurative optical fibre loop (slave). Mensurative properties are determined by traditional (mainly mechanical) measuring system ex. temperature, displacement, and optical properties are determined by characteristics of auxiliary optical system (standardised and unified). Such attitude to a subject is illustrated in this paper by the examples of threshold displacement sensor, temperature, vo…
<title>Fiber optical intensity-ratio refractometer with digital display</title>
1994
Simplicity, cost efficiency, and higher fidelity compared to the single-channel design are the main advantages stimulating the recent interest on fiber optic intensity-ratio sensors. Optical and electronic designs of refractometric sensors of this kind are discussed here. Two optical schemes of retroreflective probes with one input and two output fibers are proposed. The probe sensitivity to liquid refractivity changes in the interval 1.33 < n < 1.41 is studied by computer simulation. An originally developed one-ADC-based signal processing circuit providing digital display of the intensity-ratio determined n-values is described as well.
<title>Optical power and irradiance microprocessor meter for fiber optic sensors and networks testing</title>
1999
In this paper are presented the optical power and irradiance meter with `an intelligent opto sensor' and the microprocessor measurement system. A designed and programmed microprocessor unit allows to measure a light power from 1 nW to 2 mW and an irradiance of light from 50 nW/cm2 to 150 mW/cm2 (with accuracy 0.2%) including sensor's and spectral responsively characteristic. It's built for measuring fiber optic systems, mainly for examination and testing of the optoelectronic sensor's structure (relatively small surface of the light detectors comparing to the partition of measured value) and it's an ideal detector for the fiber optic sensors and networks.© (1999) COPYRIGHT SPIE--The Interna…
<title>Control and measuring buses with amplitude fiber optical sensors</title>
2004
This paper presents controlling-measuring buses (linear and quasi-linear) using amplitude properties of fiber-optics and fiber-optical sensors of typical and/or special construction. It refers to linear sensors and commonly used measuring OTDR method, as wel as to realizations with linear binary sensors in transmission networks. Presented advantages and parameters of such measuring structures. Presented main area of application buses and practical realizations, regarding typical needs in industrial measurements, points out technical and economical advantages, in opposition to difficult and expensive (but more accurate) technology of measuring networks based on polarization and interfering m…
<title>Fiber optic monitoring buses with binary on-off sensors</title>
1999
This paper presents general theoretical considerations of complex-structure optical fiber networks (buses) with binary `on-off' fiber optic sensors and fiber optic transmission lines for monitoring, diagnostic or measurement systems. The principles of fiber optic serial and parallel buses and various types of intensity fiber optic binary sensors are described as well as the advantages and disadvantages of the individual types of networks. The choice of the use of fiber optic technology rather than other techniques is discussed. Special emphasis was put on the role and function of optoelectronic and optical fiber devices in harsh environments. Theoretical considerations are illustrated by th…
A portable instrument for the location and identification of defects generating PD
2011
A portable instrument based on an antenna probe and suitable for partial discharge detection, have been characterized through both laboratory and on-site experiments carried out on coils and stator windings of ac rotating machines. The antenna probe allows the capture of electromagnetic waves in a bandwidth of 0.1–100 MHz. Pulse signals and ac supply voltage reference are obtained by means of high-pass and low-pass filters, respectively, so avoiding the need of a direct connection with the objects under test. By this way, real-time phase resolved partial discharge patterns can be derived. Results of a comparison of the diagnostic information provided by PD patterns due to conducted and irra…
Experimental characterization of bodycentric passive RFID systems
2011
Recent progresses in the design of wearable RFID tag antennas stimulate the idea of passive bodycentric systems wherein the required power to drive the wearable tags is directly scavenged from the interrogation signal emitted by the reader unit. While active bodycentric links have been extensively investigated, the feasibility of passive systems is still questionable due to the poor sensitivity of the tags and to the modest read distances. This paper describes an articulated measurement campaign with textile wearable low-profile tags in the UHF RFID band. It is demonstrated that both on-body and off-body links are feasible with a power budget fully compliant with the available technology. T…
Performance of two innovative stress sensors imbedded in mortar joints of new masonry elements
2021
Abstract Many historical cities enjoy the presence of masonry buildings with inestimable historical, artistic and cultural value. Old masonry buildings often suffer structural deficiencies, design faults and materials aging process. In recent years, many researchers focused their attention on the opportunities that structural health monitoring (SHM) can ensure for the health state of existing masonry structures, where damage can be difficult to be promptly predicted, pontentially causing abrupt collapses, with high risks for the community. This paper presents an experimental study on the effectiveness of two types of stress sensor for SHM of new masonry elements. Ceramic piezoelectric senso…
Three dimensional reconstruction of intracoronary ultrasound images: roadmapping with simultaneously digitised coronary angiograms
2002
Three dimensional reconstruction of intracoronary ultrasound images offers a better appreciation of the axial relationship of vessel features and permits volumetric assessment, both of which depend critically on the spatial accuracy of the technique. This in turn is dependent on precise longitudinal orientation of the transducer in the vessel. The authors have developed a system which utilises simultaneously digitised fluoroscopic tracking of the radio-opaque transducer to orient the corresponding 2D ICUS images. This system may offer improved spatial accuracy of the three dimensional reconstruction and a means of precise identification of the 2D ICUS image which corresponds with a selected…
Optimizing the MAC Protocol in Localization Systems Based on IEEE 802.15.4 Networks
2017
Radio frequency signals are commonly used in the development of indoor localization systems. The infrastructure of these systems includes some beacons placed at known positions that exchange radio packets with users to be located. When the system is implemented using wireless sensor networks, the wireless transceivers integrated in the network motes are usually based on the IEEE 802.15.4 standard. But, the CSMA-CA, which is the basis for the medium access protocols in this category of communication systems, is not suitable when several users want to exchange bursts of radio packets with the same beacon to acquire the radio signal strength indicator (RSSI) values needed in the location proce…