Search results for " Specificity"

showing 10 items of 2170 documents

Genetics of the variable expression of CYP3A in humans.

2004

CYP3A isozymes participate in the metabolism of 45-60% of currently used drugs and of a variety of other compounds such as steroid hormones, toxins, and carcinogens. The CYP3A expression status is a major determinant of drug efficacy and safety, and it may also affect an individual's predisposition to certain cancers. The inter- and intraindividual expression of CYP3A is variable because of a complex interplay between genetic and environmental factors. Markers predictive of the individual CYP3A activity could improve therapies with CYP3A substrates by personalised dose adjustments, but their development has been slower than for other drug-metabolizing enzymes. Here we summarize the recent p…

PharmacologyGeneticsRegulation of gene expressionPolymorphism GeneticCYP3A4GenomicsOxidoreductases N-DemethylatingBiologyIsozymeGene Expression Regulation EnzymologicVariable ExpressionPharmaceutical PreparationsOrgan SpecificityCytochrome P-450 CYP3ACytochrome P-450 CYP3AHumansPharmacology (medical)PharmacokineticsAryl Hydrocarbon HydroxylasesCYP3A5HormoneTherapeutic drug monitoring
researchProduct

Organic carbonates as alternative solvents for asymmetric hydrogenation

2009

Organic carbonates like propylene carbonate (PC) or butylene carbonate (BC) belong to the class of aprotic, highly dipolar solvents (AHD). Interestingly, their potential as solvents for asymmetric catalysis has been overlooked for a long time. The aim of this work is to evaluate organic carbonates and other organic solvents like THF, CH2Cl2, and acetonitrile as well as members of the AHD-family (DMF, DMSO, etc.) as media for homogeneous asymmetric hydrogenation. For this reason cationic Rh-complexes based on chiral phosphine ligands were tested in the hydrogenation of typical benchmark substrates. In several trials, significant advantages of organic carbonates were found. In contrast to DMS…

PharmacologyGreen chemistryChemistryOrganic ChemistryAsymmetric hydrogenationEnantioselective synthesisGreen Chemistry TechnologyStereoisomerismCatalysisSubstrate SpecificityAnalytical Chemistrychemistry.chemical_compoundCarbonic AcidDrug DiscoveryPropylene carbonateSolventsOrganic chemistryRhodiumHydrogenationOrganic ChemicalsSolvent effectsAcetonitrileChirality (chemistry)SpectroscopyPhosphineChirality
researchProduct

Substrate Specificity of Vinorine Hydroxylase, a Novel Membrane-bound Key Enzyme of Rauwolfia Indole Alkaloid Biosynthesis

1995

Pharmacologychemistry.chemical_classificationEnzymeIndole alkaloid biosynthesischemistryBiochemistryStereochemistryMembrane boundOrganic ChemistrySubstrate specificityAnalytical ChemistryHETEROCYCLES
researchProduct

The ability of soil-borne fungi to degrade organophosphonate carbon-to-phosphorus bonds

1997

The ability of a wide variety of soil-borne fungal strains to degrade four structurally different compounds containing P-C bonds, namely the naturally occurring amino acid ciliatine, the popular herbicide glyphosate, phosphonoacetic acid and 2-amino-3-phosphonopropionic acid, was studied in order to show that soil fungi may play an important role in the biodegradation of organophosphonates. Most of the strains appeared to utilize ciliatine as the sole source of phosphorus for growth. Only a limited number of strains were able to grow on the other phosphonates used in this work. The strains of Trichoderma harzianum, Scopulariopsis sp. and Aspergillus niger chosen for more detailed study show…

Phosphonoacetic AcidGlycinechemistry.chemical_elementApplied Microbiology and BiotechnologyBacteria AnaerobicOrganophosphorus CompoundsSpecies SpecificityFood scienceSoil MicrobiologyTrichodermachemistry.chemical_classificationAlaninebiologyAminoethylphosphonic AcidPhosphorusAspergillus nigerFungiTrichoderma harzianumPhosphorusGeneral MedicineFungi imperfectiBiodegradationbiology.organism_classificationCarbonAmino acidBacteria AerobicBiodegradation EnvironmentalchemistryBiochemistryScopulariopsisEnvironmental PollutantsOrganophosphonatesAspergillus nigerBiotechnologyApplied Microbiology and Biotechnology
researchProduct

Phosphorylation of GAP-43 (growth-associated protein of 43 kDa) by conventional, novel and atypical isotypes of the protein kinase C gene family: dif…

1996

GAP-43 (growth-associated protein of 43 kDa; also known as neuromodulin, P-57, B-50 and F-1) is a neuronal calmodulin binding protein and a major protein kinase C (PKC) substrate in mammalian brain. Here we describe the phosphorylation by and the site specificity of different PKC isotypes. The conventional PKC beta 1 and the novel PKCs delta and epsilon effectively phosphorylated recombinant GAP-43 in vitro; atypical PKC zeta did not. The K(m) values (between 0.6 and 2.3 microM) were very low, demonstrating a high-affinity interaction between kinase and substrate. All PKC isotypes were shown to phosphorylate serine-41 in GAP-43. When using a 19-amino-acid oligopeptide based on the GAP-43 ph…

PhosphopeptidesCalmodulinMolecular Sequence DataNerve Tissue ProteinsPeptidePeptide MappingBiochemistrySubstrate SpecificityGAP-43 ProteinAmino Acid SequencePhosphorylationGap-43 proteinMolecular BiologyProtein Kinase CProtein kinase Cchemistry.chemical_classificationOligopeptideMembrane GlycoproteinsbiologyKinaseBinding proteinCell BiologyMolecular biologyRecombinant ProteinsIsoenzymesKineticsBiochemistrychemistryMultigene Familybiology.proteinPhosphorylationPeptidesOligopeptidesResearch ArticleBiochemical Journal
researchProduct

Power saturation of ESR signal in ammonium tartrate exposed to 60Co gamma-ray photons, electrons and protons.

2006

Abstract Marrale, M., Brai, M., Triolo, A., Bartolotta, A. and D'Oca, M. C. Power Saturation of ESR Signal in Ammonium Tartrate Exposed to 60Co γ-Ray Photons, Electrons and Protons. Radiat. Res. 166, 802–809 (2006). In this paper we present an investigation of the electron spin resonance (ESR) line shape of ammonium tartrate (AT) dosimeters exposed to radiation with different linear energy transfer (LET). We exposed our dosimeters to γ-ray photons (60Co), 7 MeV and 14 MeV initial energy electrons, and 19.3 MeV initial energy protons. The differences in the power saturation behavior of ESR spectra of AT irradiated with photons, electrons and protons could be correlated to the effective LET o…

PhotonBiophysicsLinear energy transferElectronsElectronRadiationRadiation DosageSensitivity and Specificitylaw.inventionlawRadiology Nuclear Medicine and imagingLinear Energy TransferIrradiationCobalt RadioisotopesElectron paramagnetic resonanceRadiometrySaturation (magnetic)TartratesPhotonsRadiationDosimeterChemistryElectron Spin Resonance SpectroscopyReproducibility of ResultsDose-Response Relationship RadiationAmmonium Tartrate 60Co -Ray Photons Electrons and Protons.Gamma RaysAtomic physicsProtonsAlgorithmsRadiation research
researchProduct

The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.

2014

Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…

PhotonQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsMonte Carlo methodAnalytical chemistryBoron Neutron Capture TherapySensitivity and SpecificityOpticsNuclear ReactorsDosimetryPenelopeIonization ChamberDosimetryComputer SimulationPhoton beamRadiometryMonte CarloPhysicsPhotonsRadiationModels Statisticalbusiness.industryAirRadiotherapy Planning Computer-AssistedReproducibility of ResultsEquipment DesignNeutron radiationEquipment Failure AnalysisIonization chamberBNCTPhysics::Accelerator PhysicsComputer-Aided DesignDose ratebusinessMCNP5Beam (structure)Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Phantom size in brachytherapy source dosimetric studies

2004

An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom s…

Photonmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyModels BiologicalSensitivity and SpecificityImaging phantomRelative biological effectivenessmedicineHumansScattering RadiationDosimetryComputer SimulationPoint (geometry)RadiometryRadioisotopesPhysicsPhantoms Imagingbusiness.industryRadiotherapy Planning Computer-AssistedReproducibility of ResultsRadiotherapy DosageGeneral MedicineRadiusComputational physicsOrgan SpecificityBody BurdenRadiopharmaceuticalsNuclear medicinebusinessMonte Carlo MethodAlgorithmsRelative Biological EffectivenessMedical Physics
researchProduct

Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events

2014

The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events will attempt to determine which of the possible candidate lines of response (LoRs) correctly determine the annihilation photon trajectory. However, methods of assessment often have low su…

PhotonsRadiological and Ultrasound TechnologyPhantoms ImagingComputer scienceScatteringIterative reconstructionSensitivity and SpecificityImaging phantomSignal-to-noise ratioPositron-Emission TomographyImage Processing Computer-AssistedScattering RadiationRadiology Nuclear Medicine and imagingTomographySensitivity (control systems)AlgorithmAlgorithmsSimulationPhysics in Medicine and Biology
researchProduct

Superresolution digital holographic microscopy for three-dimensional samples.

2009

An approach that allows superresolution imaging of three-dimensional (3-D) samples by numerical refocusing is presented in the field of digital holographic microscopy. Based on the object's spectrum shift produced by tilted illumination, we present a time multiplexing superresolved approach to overcome the Abbe's diffraction limit. The proposed approach uses a microscope in a Mach-Zehnder interferometric architecture with the particularity that the output plane does not coincide with the image plane. Thus, a set of off-axis non-image plane holograms are sequentially recorded for every tilted beam used in the illumination stage. After that and by using simple digital post-processing and nume…

PhysicsMicroscopyMicroscopebusiness.industryHolographyPhysics::OpticsReproducibility of ResultsSignal Processing Computer-AssistedEquipment DesignImage planeImage EnhancementSensitivity and SpecificityAtomic and Molecular Physics and Opticslaw.inventionLens (optics)Equipment Failure AnalysisInterferometryOpticsImaging Three-DimensionallawMicroscopyDigital holographic microscopybusinessDigital holographyOptics express
researchProduct