Search results for " Stability"
showing 10 items of 1355 documents
Modeling Round Robin Test: An Uncoupled Approach
2014
Abstract The solution of the modeling test presented in the paper is based on an uncoupled hydro-mechanical approach. Firstly, the controlled infiltration process is modeled by a finite element transient groundwater seepage software. Afterwards, calculated pore water pressures at successive instants are used for the slope stability analysis. Time evolution of the slope stability is analysed by using the infinite slope model, according to the classical limit equilibrium method.
Control of the Biodegradation of Mixed Wastes in a Continuous Bioreactor by a Type-2 Fuzzy Logic Controller
2009
Abstract Type-2 fuzzy logic control is proposed for nonlinear processes characterized by bifurcations. A control simulation study was conducted for a bioreactor with cell recycle containing phenol and glucose as carbon and energy sources in which a pure culture of Pseudomonas putida is carried out. The model developed by Ajbar [Ajbar, A. (2001). Stability analysis of the biodegradation of mixed wastes in a continuous bioreactor with cell recycle. Water Research, 35 (5), 1201–1208] was used for the simulations. The particular dynamics of the bioreactor, characterized by two saddle-node bifurcations, makes its control difficult, since it may become unstable also for small variations of some p…
Nonlinear Control of a Pneumatic Muscle Actuator System
2001
Abstract The performance of a Pneumatic Muscle Actuator under three tracking control strategies is compared: robust backstepping, sliding-mode and gain scheduling. Robustness is assured for the three controllers in the presence of model uncertainties and external perturbations. Exponential stability is proved for the sliding-mode tracking controller, ultimate boundedness for the backstepping tracking controller and exponential stability for constant or slowly-varying reference signals for the gain scheduling controller. Computer simulations show a good performance for the tracking of a sine wave by the first two controllers, although the sliding-mode strategy yields a high-frequency switchi…
Reassessment of voltage stability for distribution networks in presence of DG
2016
There is a growing interest in integrating renewable energy based distributed generation (DG) in the electrical power distribution networks. The installation of DG units at distribution level impacts critically the planning and operation characteristics of the network. The type, location, number and capacity of the integrated DGs affects system behavior and performance. In this paper the effect of installing new DGs on the distribution network voltage stability is studied. The optimal location of the newly installed DGs are decided based on the Power Stability Index (PSI) and Voltage Stability Index (VSI). Moreover, Voltage Stability Margin (VSM) of the interconnected DG distribution networ…
Effects of electrical and mechanical parameters on the transient voltage stability of a fixed speed wind turbine
2011
Abstract In this paper the dynamic behaviour of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed with the Simulink simulation tool (Matlab Inc.) It is composed of the induction generator, the shaft system, an aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phase fault is applied close to the wind turbine and cleared by disconnecting the faulty line. The rigorous implementation of the simulink model allowed the authors to evaluate the exact dependence of various electrical parameters for the induction generator on voltage stability. Furthermore, the effects of wind turbine mechan…
Effect of FRP Wraps on the Compressive Behaviour of Slender Masonry Columns
2017
In the last decade, Fibre Reinforced Polymer (FRP) wrapping technique has become a common method to retrofit masonry piers or columns with poor structural performances. The passive confinement effect induced by the external wrap allows increasing the compressive strength and ductility of the member. Several studies highlighted as the efficacy of this technique is affected by several key parameters, including the shape of the transverse cross section, stress intensification at the strength corner of sharp sections, amount and mechanical properties of adopted composite. Despite this technique has been widely studied from both theoretical and experimental point of view, most of studies focused…
A Simple Method to Assess Loadability of Radial Distribution Networks
2005
This paper proposes a simple method to asses loadability in radial distribution systems. The relevant problem of voltage stability has been dealt with in past times with reference to higher voltage systems for generation and transmission. In more recent papers, the problem has been considered also at distribution level, since the new electrical energy market requirements and the increasing loadings are now more and more influencing these systems. The proposed method is based on a static approach and proceeds by first evaluating the stability indices and then the different loadability factors (related to real, reactive and apparent power). These calculations are carried out by identifying, s…
On the sway stability improvement of car–caravan systems by articulated connections
2015
The present analysis is addressed to some promising connection arrangements between the towing vehicles and the towed trailers, where the two units are linked by four-bar isosceles trapeziums in place of the conventional pintle hitch. Two types of instability, of the divergent type or the oscillating type, may be analysed by the Routh–Hurwitz criterion or by the direct analysis of the characteristic equation. The constant term of this equation vanishes at the divergent instability threshold (zero of a real root), whereas the equation splits into two lower degree algebraic ‘sub-equations’ when the oscillating instability arises (pair of pure imaginary roots). A large field of geometrical con…
Impedance estimation of FEA's grid in fiji islands by V-I measurement by using the synchronous reference frame-PLL
2017
In recent years there has been a significant increase in distributed renewable energy generation feeding into the grid, with resulting detriment of the stability of the network, since present networks have not been designed for this purpose. To feed-in these renewable energy sources with minimum impact, it is essential to know a few grid parameters (voltage, current, grid impedance) at the point in which power supply is convenient. For this purpose in this paper an algorithm is proposed to obtain the estimated network impedance. This algorithm operates in time domain by a synchronous reference coordinate transformation, it requires only the measurement of the phase voltage with no-load and …
Wind Turbine Mechanical Characteristics and Grid Parameters Influence on the Transient Voltage Stability of a Fixed Speed Wind Turbine
2008
This paper describes the effect of wind turbine mechanical characteristic of construction and grid parameters on the transient voltage stability of a fixed speed wind turbine (FSWT) connected to a simple grid. The model of FSWT has been developed in Matlab/Simulink. Using this model, a three-phase fault is applied close to the wind turbine (WT) and cleared by disconnecting the faulted line. The effects of mechanical construction of WT and of grid parameters on the voltage stability of this simple case are evaluated and discussed. The considered parameters are the inertia coefficient of the WT, the short-circuit power at the connection bus, the hub-generator resonant frequency, the wind spee…