Search results for " Steri"

showing 10 items of 49 documents

Pratiche di disinfezione, sterilizzazione e disinfestazione

2012

Disinfezione sterilizzazione disinfestazioneSettore MED/42 - Igiene Generale E Applicata
researchProduct

Lipid Nanoparticles for Drug Targeting to the Brain

2012

In this chapter, the main production methods of lipid nanostructures such as solid lipid nanoparticles and nanostructured lipid carriers, and their application are described. In particular, we describe the strategies commonly used to obtain lipid nanoparticles to overcome the blood-brain barrier (BBB) for the treatment of several brain diseases. The use of these carriers as targeted drug delivery systems is associated with many advantages that include excellent storage stability, easy production without the use of any organic solvent, the possibility of steam sterilization and lyophilization, and large scale production. They exhibit good stability during long-term storage, consist of physio…

DrugChemistrymedia_common.quotation_subjectOrganic solventNanoparticleNanotechnologySteam sterilizationTargeted drug deliverySettore CHIM/09 - Farmaceutico Tecnologico ApplicativoNanoparticles for drug delivery to the brainGenerally recognized as safeSolid lipid nanoparticlesolid lipid nanoparticles blood brain barriermedia_common
researchProduct

El valor de la Fisiocracia en su propio tiempo: un análisis crítico

2009

The value of the physiocratic doctrine is examined with an historical-analytical approach that takes into account both the French reality of the mid 18th century and the internal consideration of the doctrine. Starting from the overwhelming opposition of the French contemporaries, the three areas of the phyisiocrats’ system are critically reviewed: the philosophical-political framework, the theoretical economic analysis and the main maxims of the economic government. We conclude that Physiocracy, together with presenting some analytical advances, diagnosed the French economy inadequately, incurred in outstanding economic errors and proposed, within the political framework of severe “legal d…

Economics and EconometricsHistoryQuesnay Physiocracy Tableau économique Productivity and Sterility Error.
researchProduct

Inactivation of dried spores of Bacillus subtilis 168 by a treatment combining high temperature and pressure

2019

International audience; Specific treatments combining high temperatures of up to 150 °C and moderate pressure of up to 0.6 MPa have been applied to Bacillus subtilis 168 spores conditioned at different aw levels (between 0.10 and 0.70) corresponding to different residual water contents within the spore core. The spores were treated as a dry powder in a pressurized nitrogen environment or in water/glycerol solutions.These thermodynamic conditions were intended to prevent any water evaporation from the spore core during time/temperature treatments.Our results clearly show that retaining liquid water in the core by applying pressure during the treatment resulted in greater spore destruction (b…

Food powderHot TemperatureWater activityNitrogenchemistry.chemical_elementBacillus subtilisMicrobiology03 medical and health scienceschemistry.chemical_compound[SDV.IDA]Life Sciences [q-bio]/Food engineeringGlycerolPressureFood science030304 developmental biologySpores Bacterial0303 health sciencesMicrobial ViabilitybiologyAtmospheric pressure030306 microbiologyfungiWaterDry foodGeneral Medicinebiology.organism_classificationNitrogenThermal sterilization[SDV.MP.BAC]Life Sciences [q-bio]/Microbiology and Parasitology/BacteriologySporeBoiling pointTemperature and pressurechemistry13. Climate actionFood MicrobiologyBacillus sporesBacillus subtilisFood ScienceWater activity
researchProduct

Understanding the detector behavior through Montecarlo and calibration studies in view of the SOX measurement

2015

International audience; Borexino is an unsegmented neutrino detector operating at LNGS in central Italy. The experiment has shown its performances through its unprecedented accomplishments in the solar and geoneutrino detection. These performances make it an ideal tool to accomplish a state- of-the-art experiment able to test the existence of sterile neutrinos (SOX experiment). For both the solar and the SOX analysis, a good understanding of the detector response is fundamental. Consequently, calibration campaigns with radioactive sources have been performed over the years. The calibration data are of extreme importance to develop an accurate Monte Carlo code. This code is used in all the n…

HistoryGeoneutrinoCalibration (statistics)Physics::Instrumentation and DetectorsNuclear engineeringMonte Carlo method01 natural sciencesprogrammingParticle detectorEducationPhysics and Astronomy (all)0103 physical sciencesddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsSimulationBorexinoPhysics010308 nuclear & particles physicsDetectorneutrino: sterilecalibrationComputer Science::Computers and SocietyComputer Science ApplicationsNeutrino detectorBorexinoHigh Energy Physics::ExperimentNeutrinonumerical calculations: Monte Carloperformance
researchProduct

SOX: search for short baseline neutrino oscillations with Borexino

2015

International audience; The Borexino detector has convincingly shown its outstanding performances in the low energy regime through its accomplishments in the observation and study of the solar and geo neutrinos. It is then an ideal tool to perform a state of the art source-based experiment for testing the longstanding hypothesis of a fourth sterile neutrino with ~ eV(2) mass, as suggested by several anomalies accumulated over the past three decades in source, reactor, and accelerator-based experiments. The SOX project aims at successively deploying two intense radioactive sources, made of Cerium (antineutrino) and Chromium (neutrino), respectively, in a dedicated pit located beneath the det…

HistoryParticle physicsSterile neutrinochromium: nuclidePhysics::Instrumentation and DetectorsSolar neutrino[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyEducationNuclear physicsPhysics and Astronomy (all)0103 physical sciencesddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsNeutrino oscillationBorexinoactivity reportPhysics010308 nuclear & particles physicsHigh Energy Physics::Phenomenologyneutrino: particle sourceSolar neutrino problemneutrino: sterilesensitivityComputer Science ApplicationsNeutrino detector13. Climate actioncerium: nuclideMeasurements of neutrino speedHigh Energy Physics::ExperimentBorexinoneutrino: oscillationNeutrinoantineutrino: particle source
researchProduct

The $^{144}$Ce source for SOX

2015

International audience; The SOX (Short distance neutrino Oscillations with BoreXino) project aims at testing the light sterile neutrino hypothesis. To do so, two artificials sources of antineutrinos and neutrinos respectively will be consecutively deployed at the Laboratori Nazionali del Gran Sasso (LNGS) in close vicinity to Borexino, a large liquid scintillator detector. This document reports on the source production and transportation. The source should exhibit a long lifetime and a high decay energy, a requirement fullfilled by the (144)Ce-(144)Pr pair at secular equilibrium. It will be produced at FSUE “Mayak” PA using spent nuclear fuel. It will then be shielded and packed according t…

HistorySterile neutrinoParticle physicsenergy: decay[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Scintillator01 natural sciences7. Clean energyEducationNuclear physicsPhysics and Astronomy (all)0103 physical sciencesddc:530010306 general physicsNeutrino oscillationparticle sourceBorexinoPhysicslifetimenucleusSecular equilibriumneutrino: sterileantineutrinosensitivitySpent nuclear fuelComputer Science ApplicationsGran SassoceriumDecay energyradioactivityBorexinoneutrino: oscillationproductionNeutrino
researchProduct

Solar neutrino detectors as sterile neutrino hunters

2016

International audience; The large size and the very low radioactive background of solar neutrino detectors such as Borexino at the Gran Sasso Laboratory in Italy offer a unique opportunity to probe the existence of neutrino oscillations into new sterile components by means of carefully designed and well calibrated anti-neutrino and neutrino artificial sources. In this paper we briefly summarise the key elements of the SOX experiment, a program for the search of sterile neutrinos (and other short distance effects) by means of a (144)Ce-(144)Pr anti-neutrino source and, possibly in the medium term future, with a (51)Cr neutrino source.

HistorySterile neutrinoParticle physicsneutrino: solarPhysics::Instrumentation and DetectorsSolar neutrinoAstrophysics::High Energy Astrophysical Phenomena01 natural sciences7. Clean energyEducationPhysics and Astronomy (all)0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex][PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsNeutrino oscillationnuclideBorexinoPhysics010308 nuclear & particles physicsHigh Energy Physics::PhenomenologySolar neutrino problemneutrino: sterileComputer Science ApplicationspraseodymiumGran Sassoneutrino: detectorNeutrino detectorcerium: nuclideHigh Energy Physics::Experimentneutrino: oscillationNeutrino astronomyNeutrinoantineutrino: particle source[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]
researchProduct

Effects of gamma-irradiation on trehalose–hydroxyethylcellulose microspheres loaded with vancomycin

2003

Ionizing radiation can be used as a drug sterilization technique, provided that the drug itself is not modified and that no toxic products are produced; moreover, if the irradiated product is a drug delivery system, the drug release characteristics must not be significantly altered by radiation. The aim of this work was to study the effects of sterilization by ionizing radiation on hydroxyethylcellulose/trehalose spherical micromatrices, containing the antibiotic vancomycin. Our experimental results showed that gamma-rays did not alter the chromophore groups of vancomycin (UV measurements), and did not modify the kinetic behavior of drug release from microspheres. Moreover, no significant c…

Ionizing radiationMicrosphereDrugmedia_common.quotation_subjectDrug delivery systemGamma-irradiationPharmaceutical Sciencelaw.inventionIonizing radiationchemistry.chemical_compoundVancomycinlawmedicineIrradiationCelluloseElectron paramagnetic resonanceESRmedia_commonRadiochemistryTrehaloseQuality controlGeneral MedicineSterilization (microbiology)Drug sterilizationTrehaloseMicrosphereschemistryGamma RaysDrug deliveryVancomycinBiotechnologymedicine.drugEuropean Journal of Pharmaceutics and Biopharmaceutics
researchProduct

Aseptic Production vs. Terminal Sterilization

2000

The safety of substance use in intraocular surgery ideally requires the absence of all biologically-active components capable of causing an inflammatory reaction. Substance purity is achieved with isolation and cleansing methods (e.g., of the polysaccharide), which remove any biological component with infective potential. The methods of production for polysaccharide isolation should remove biological agents, regardless of its origin. Hyaluronic acid is isolated either from rooster combs or biological fermentation. Use of this substance showed the development of postoperative intraocular inflammatory reactions resulting from contaminations from both sources. OVD should have low endotoxin val…

Methods of productionSterilization processSterilityChemistryTerminal SterilizationAseptic processingIntraocular surgeryFood scienceSubstance useSterility assurance level
researchProduct