Search results for " Structural"
showing 10 items of 1751 documents
A noninvasive approach for the assessment of dental implants stability
2015
We propose the Electromechanical Impedance (EMI) technique to monitor the stability of dental implants. The technique consists of bonding one wafer-type piezoelectric transducers to the implant system. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer’s electrical admittance. The hypothesis is that the health of the bone surrounding the implant affects the sensor’s admittance. In this paper we present the results of an experiment where a sensor is bonded to an abutment screwed to implants secured into bovine bone samples. The results show that the EMI technique can be used to monitor the stability of dental implants alth…
Highly nonlinear solitary waves for the NDT of slender beams
2015
Slender beams subjected to compressive load are common in civil engineering. The rapid in-situ measurement of this stress may help preventing structural anomalies. In this article we describe the coupling mechanism between Highly Nonlinear Solitary Waves (HNSWs) propagating along a granular system in contact with a beam subjected to thermal stress. We evaluate the use of these waves to measure stress in thermally loaded structures and to estimate the neutral temperature, i.e. the temperature at which the stress is null. We investigate numerically and experimentally one and two L-shaped chains of spherical particles in contact with a prismatic beam subjected to heat. We find that certain fea…
Novel fuzzy-based optimization approaches for the prediction of ultimate axial load of circular concrete-filled steel tubes
2021
An accurate estimation of the axial compression capacity of the concrete-filled steel tubular (CFST) column is crucial for ensuring the safety of structures containing them and preventing related failures. In this article, two novel hybrid fuzzy systems (FS) were used to create a new framework for estimating the axial compression capacity of circular CCFST columns. In the hybrid models, differential evolution (DE) and firefly algorithm (FFA) techniques are employed in order to obtain the optimal membership functions of the base FS model. To train the models with the new hybrid techniques, i.e., FS-DE and FS-FFA, a substantial library of 410 experimental tests was compiled from openly availa…
Torre para comunicaciones y prácticas de bomberos en la Eliana, Valencia. España
1992
The article brings the description of the characteristics of the project and the execution of the work on a communication tower which should also serve for practices of fire brigades and which has a water tank in the base.
Simplified technique for constitutive analysis of SFRC
2014
Steel fibre reinforced concrete (SFRC) has become widespread material in areas such as underground shotcrete structures and industrial floors. However, due to the absence of material models of SFRC reliable for numerical analysis, application fields of this material are still limited. Due to interaction of concrete with fibres, a cracked section is able to carry a significant portion of tensile stresses, called the residual stresses. In present practices, residual stresses used for strength, deflection and crack width analysis are quantified by means of standard tests. However, interpretation of these test results is based on approximation using empirically deduced relationships, adequacy o…
A numerical solution that determines the temperature field inside phase change materials: application in buildings
2013
The use of novel building materials that contain active thermal components would be a major advancement in achieving significant heating and cooling energy savings. In the last 40 years, Phase Change Materials or PCMs have been tested as thermal mass components in buildings, and most studies have found that PCMs enhance the building energy performance. The use of PCMs as an energy storage device is due to their relatively high fusion latent heat; during the melting and/or solidification phase, a PCM is capable of storing or releasing a large amount of energy. PCMs in a wall layer store solar energy during the warmer hours of the day and release it during the night, thereby decreasing and sh…
REVIEWERS
2015
"Reviewers " Journal of Civil Engineering and Management, 21(8), pp. I–V
Vegetation growth parameters and leaf temperature: Experimental results from a six plots green roofs' system
2016
Abstract The paper provides a contribution for populating database of three physical parameters needed to model energy performance of buildings with green roofs: “coverage ratio” ( σ f ), leaf area index (LAI) and leaf temperature ( T f ). On purpose, six plant species were investigated experimentally: Phyla nordiflora, Aptenia lancifolia , Mesembryanthenum barbatus , Gazania nivea, Gazania uniflora , and Sedum . Proper ranges of the cited parameters have been found for each species. The here indicated ranges of σ f values refer to different growth levels of the species in the same lapse of time, that is four months. Single measured LAI values are also reported for the same plants. As for t…
Impact of building automation control systems and technical building management systems on the energy performance class of residential buildings: An …
2014
Abstract The paper focuses on the evaluation of the impact on residential buildings of building automation control (BAC) and technical building management (TBM) systems. This work shows how the control, monitoring and automation functions considered by the European Standard EN 15232 can considerably influence the energy performance of a single-family test house and, consequently, its energy performance class. The study puts into evidence that the benefit that can be drawn from the installation of BAC and TBM systems depends on the type of technical appliances in the household and on the starting energy performance class. Finally, the economic impact due to the introduction of BACS or TBM fu…
Investigating energy saving potential in a big shopping center through ventilation control
2019
Abstract This paper investigates energy saving measures for the ventilation system of large shopping centers. This kind of buildings is characterized by high yearly energy consumptions, because of the high level of operating hours and the frequent use of obsolete technologies. In the analyzed case studies, three big Do It Yourself (DIY) shops, located in Italy, are considered. Two different approaches are considered, they are aimed at reducing the annual energy consumption for the indoor air exchange of the sales area. The first considered retrofit solution consists in the installation of heat recovery exchangers, reducing the energy demand for the air thermal treatment without changing the…