Search results for " Surgery."
showing 10 items of 3972 documents
Long-term results of the use of silicone sheets after diskectomy in the temporomandibular joint: clinical, radiographic and histopathologic findings
1999
The aim of the present study was to evaluate the long-term results of a group of patients who had the disk of the temporomandibular joint (TMJ) removed and permanently replaced by a silicone sheet. The study group comprised 48 patients, treated in the period from 1983 to 1993. In eight patients, the implants had to be removed after an average interval of 5.6 years and they were submitted for histopathological examination. Twenty-five of the 40 patients with silastic implants in place, and five of the 8 patients who had their implants removed, were available for long-term follow-up (mean interval of 7.0 years, SD 2.8 years). Clinical function was rated according to the Helkimo Dysfunction In…
Short-Term Impact of FS-LASIK and SMILE on Dry Eye Metrics and Corneal Nerve Morphology
2020
PURPOSE To analyze the short-term (up to 1 month) clinical outcomes in patients undergoing corneal laser refractive surgery and the impact on dry eye disease (DED) metrics and corneal nerves using in vivo confocal microscopy (IVCM). METHODS The unaided distance visual acuity, corrected distance visual acuity, and spherical equivalent refraction (SEQ) were determined in 16 and 13 patients undergoing FS-LASIK and SMILE, respectively. DED metrics assessed were Ocular Surface Disease Index, Dry Eye Questionnaire 5-items (DEQ-5), tear film osmolarity, tear meniscus height, noninvasive keratograph breakup time (NIKBUT), ocular staining, and meibomian gland atrophy. An automated analysis of cornea…
Pain and swelling after periapical surgery related to the hemostatic agent used: anesthetic solution with vasoconstrictor or aluminum chloride.
2011
Objective: To assess pain and swelling in the first 7 days after periapical surgery and their relationship with the agent used for bleeding control. Study Design: A prospective study was conducted between October 2006 and March 2009. Patients subjected to root surgery, who completed the questionnaire and who consented to the postoperative instructions were included in the study. The subjects were divided into two groups according to the hemostatic agent used: A) gauze impregnated with anesthetic solution with vasoconstrictor; or B) aluminum chloride. The patients were administered a questionnaire, and were asked to record the severity of their pain and swelling on a plain horizontal visual …
Odontogenic tumors: a collaborative study of 218 cases diagnosed over 12 years and comprehensive review of the literature.
2015
Objectives: The objective of this study was to analyze the frequency and distribution of odontogenic tumors (OTs) in the Cappadocia region of Turkey, and to compare the findings with those reported in the literature. Study Design: The records of the Oral and Maxillofacial Surgery and Pathology Departments at Erciyes University, with histologic diagnosis of odontogenic tumors (based on the World Health Organization classification, 2005), over a 12-year period, were analyzed. The relative frequency of different types of tumors was also analyzed and compared with the literature. Results: OTs in the present study constituted 2.74% of all the 7,942 registered biopsies. A total of 218 cases of OT…
Choice of spatial frequency for contrast sensitivity evaluation after corneal refractive surgery.
2002
ABSTRACT PURPOSE: To study the utility of measurements of contrast sensitivity at different spatial frequencies as an index of visual recovery following refractive surgery. METHODS: Contrast sensitivity at 1.5, 3, 6, 12, and 18 c/deg was measured with the Stereo Optical FACT chart in 20 patients after photorefractive keratectomy (PRK) using the Nidek EC-5000 excimer laser system, and in 18 patients following laser in situ keratomileusis (LASER). Contrast sensitivity was measured preoperatively and 1, 3, 6, and 12 months after surgery. RESULTS: Results showed a statistically significant reduction (P<01) in contrast sensitivity at all spatial frequencies in PRR patients during the first an…
Dose-Adjusted Thrombosis Prophylaxis in Trauma Surgery According to Levels of D-Dimer
2000
In 234 trauma surgery patients, thrombosis prophylaxis with Nadroparin-Calcium low-molecular-weight heparin (LMWH) was adjusted according to levels of D-Dimer. Basic prophylaxis was 2,850 IU per day. If D-Dimer concentrations rose above 2 mg/L after the fourth postoperative (p.o.) day, LMWH was administered twice a day. Color Doppler ultrasound was performed between the fifth and seventh p.o. days. Patients were divided into a high-risk (group 1: hip, femur, or knee replacement surgery, n=102) and a moderate-risk group (group 2: other surgery of the knee, tibia, fibula, or foot, n=132). Group 1 showed significantly higher D-Dimer levels than group 2 (p0.001). Measurement of D-Dimer on days …
Descriptive and follow-up study of patients treated surgically for abdominal aortic aneurysm at tertiary hospitals in Spain.
2019
BACKGROUND The aim of this study was to assess potential variability in the clinical characteristics and treatment of patients undergoing elective surgery for abdominal aortic aneurysm (AAA) across five hospitals in Spain. METHODS Multicenter, retrospective cohort study of patients diagnosed with AAA and treated with open surgical repair (OSR) or endovascular aneurysm repair (EVAR). We evaluated clinical and demographic variables, including comorbidity (Charlson Comorbidity Index [CCI]); anatomic characteristics; surgical risk (ASA Score); aneurysm characteristics; and in-hospital and overall mortality. All patients were followed for three years. RESULTS A total of 186 patients were include…
Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms
2011
Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…
Short and long term results after intracoronary stenting in human coronary arteries: monocentre experience with the balloon-expandable Palmaz-Schatz …
1991
OBJECTIVE--Intracoronary stenting was designed to overcome acute complications after percutaneous transluminal coronary angioplasty and to achieve a reduced rate of restenosis, both of which are major limitations of this well accepted method for treating coronary heart disease. This report describes the experience at one centre with the implantation of balloon-expandable Palmaz-Schatz stents and focuses on device related complications and the short and long term angiographic outcome. DESIGN--A retrospective data analysis. PATIENTS--Stenting was attempted in 50 patients. Restenosis after an initially successful angioplasty procedure, inadequate postangioplasty results, saphenous coronary byp…
Survival of immediately versus delayed loaded short implants: a prospective case series study
2015
Background: To assess and compare survival rates of immediately and delayed loaded short implants (7 mm) in free ends of a partially edentulous jaw with moderate-severe alveolar bone resorption. Material and Methods: 24 patients with atrophic edentulous free-ends were included in this prospective study. Four study groups were monitored monthly and their behavior was evaluated: bridges supported only by short implants and mixed short and long implant bridge groups, both with immediate and delayed loading. Failures, bone loss, probing depth and bleeding on probing were evaluated. Results: 54 Mk III Shorty TiU and 15 Brånemark System®MK III TiU implants with a length longer than 7mm were inclu…