Search results for " Thermal"
showing 10 items of 492 documents
Analyzing the anisotropy of thermal infrared emissivity over arid regions using a new MODIS land surface temperature and emissivity product (MOD21)
2015
Abstract The MOD21 Land Surface Temperature and Emissivity (LST&E) product will be included in forthcoming Moderate Resolution Imaging Spectroradiometer (MODIS) Collection 6. Surface temperature and emissivities for thermal bands 29 (8.55 μm), 31 (11 μm) and 32 (12 μm) will be retrieved using the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) Temperature and Emissivity Separation (TES) method adapted to MODIS at-sensor spectral radiances, previously corrected with the Water Vapor Scaling method (MOD21 algorithm). We simulated MOD21 product estimates over two different sandy deserts (i.e. White Sands and Great Sands) using a series of MODIS scenes from 2010 to 2013. T…
Building energy demand assessment through heating degree days: the importance of a climatic dataset
2019
Abstract The weather is one of the main factors to consider when designing a building because it represents the most important boundary condition to affect the dynamic behaviour of the building. In the literature, many studies use the degree day to predict building energy demand. However, linking the results obtained from a generic building simulation tool with defined degree days, will not give reliable energy evaluation. The goal of this study is to demonstrate that the assessment of building energy demand through the use of the degree day is correct only if the determination of the climate index is a function of the same weather data. The relationship between Heating Degree-Day and heati…
Comparison between topographic and photogrammetric techniques for deformation monitoring of the dome of the Massimo Theatre in Palermo
2012
This paper shows the first results of a study aimed at monitoring the deformations of the dome of the Massimo Theatre in Palermo caused by thermal dilatations, with the use of topographic and photogrammetric integrated techniques. Particularly, two robotic total stations and high precision digital photogrammetric systems were employed. In order to correlate the displacements of the rollers on which the steel structure of the dome rest with the thermal gradients, different thermal images were acquired by a thermal imaging camera. The main goal of the work was to compare the two techniques with reference to very small (submillimeter) deformation measurements. The obtained results show that th…
Monitoraggio delle deformazioni della cupola del Teatro Massimo di Palermo con l’impiego di tecniche topografiche e fotogrammetriche integrate.
2012
L’articolo riporta i primi risultati di uno studio finalizzato al monitoraggio delle deformazioni della cupola del Teatro Massimo di Palermo provocate dalle dilatazioni termiche, con l’impiego di tecniche topografiche e fotogrammetriche integrate. In particolare, sono state utilizzate due stazioni totali robotizzate e sistemi di fotogrammetria digitale di elevata precisione. Per correlare gli spostamenti dei carrelli sui quali poggia la struttura in acciaio della cupola con i gradienti termici, sono state acquisite immagini termiche diversificate. L’obiettivo principale del lavoro consisteva nel confronto delle due tecniche di rilievo in relazione a misure di deformazione di entità molto ri…
Exergy analysis and thermoeconomic cost accounting of a CHP steam cycle integrated with MED-TVC desalination
2016
In this paper exergy analysis and thermoeconomic cost accounting of a CHP steam cycle integrated with MED-TVC plant is performed; the purpose is to show how this methodology provides a rational criterion to allocate production costs on electricity and freshwater. After a brief overview on methodology and a description of reference plant, exergy analysis is carried out in order to calculate exergy flows and plant exergetic performance. A detailed description of the adopted thermoeconomic model is given. Cost accounting is performed considering two scenarios: in the first, the concentrated brine is disposed back to sea, thus being its exergy content definitively wasted; in the second, convers…
Energy performance improvements of a DEC system due to wet heat exchangers
2011
This work concerns an innovative desiccant and evaporative cooling (DEC) system for building air conditioning. The original system is an experimental DEC air handling unit installed at the Solar Laboratory of the University of Palermo and recently modified and updated. With the aim to increase the cooling effect due to water evaporation in the return air flow rate, the sensible heat exchanger was replaced with two cross flow flat plate heat exchangers installed in series, with continuous humidification of the secondary air flow. The new thermodynamic cycle is theoretically described and the realization of the real application is shown. Detailed operational data and energy performance indica…
Thermal studies of sulphonamide derivative complexes
1991
Abstract A thermal study of a new series of acetazolamidate complexes of Co(II), Ni(II) and Cu(II) using the TG, DTG and DTA techniques in flowing air, static air and N 2 atmospheres is described. From the TG-DTG and DTA curves, different thermal behaviours can be observed. Although in all the complexes the processes of dehydration, deammination and pyrolysis can be clearly observed, in some cases they appear as several well-separated steps and, in others, as continuous stages which take place simultaneously. The differences observed between the pyrolytic decomposition in flowing air and in nitrogen are described. In flowing air, metal sulphate is formed from the thiadiazole ring, except fo…
Development of a new peat-based oil sorbent using peat pyrolysis
2013
The growing use and transport of crude oil and oil products has led to increasing numbers of oil spillages of various scales. Oil sorbents have been extensively used for remediation of the consequences of such accidents. The aim of this study is to investigate the possible use of peat and its thermal treatment products for oil sorption. Peat as an oil sorbent has poor buoyancy characteristics, relatively low oil sorption capacity and low hydrophobicity. However, thermal treatment (low-temperature pyrolysis and synthesis of peat-based activated coal) helps to significantly improve its sorptive characteristics. Peat is a potential material for oil sorption because it has such advantages as lo…
Powder X-Ray Diffraction Investigation of Xylazine Hydrochloride Solid Phase Transformation Kinetics
2013
The kinetics of the solid-state phase transformation of xylazine hydrochloride form X to A has been investigated using powder X-ray diffraction and differential thermal analysis. Three different kinetic models have been used to describe transition kinetics: the Avrami–Erofeev equation, the Cardew equation, and the methodology for simulation of solid-state phase transition kinetics by the combination of nucleation and nuclei growth processes. The latter has been recently developed and has been tested in this paper for the case of a real solid-state transition. The relative humidity, mechanical pressure, temperature, and sample-preparation effect on phase-transition kinetics have been investi…