Search results for " Threshold"

showing 10 items of 497 documents

Color and lightness constancy in different perceptual tasks

1998

Color and lightness constancy with respect to changing illumination was studied with three different perceptual tasks: ranking of colored papers according (1) to their lightness and (2) to their chromatic similarity in photopic, mesopic, and scotopic states of adaptation, and (3) recognition of remembered colored papers after changes of illumination in photopic vision. Constancy was found in the second task, only. Excitations of light receptors and luminance channels were computed to simulate the empirical rank orders. Results of the first task can be predicted with the hypothesis that luminance channels are activated, if lightness is asked for. Sequences arranged with respect to chromatic …

AdultMaleLightnessGeneral Computer ScienceMesopic visionColor visionColorAdaptation (eye)Discrimination LearningHumansComputer visionScotopic visionMathematicsColor constancyAdaptation Ocularbusiness.industryCIECAM02Sensory ThresholdsRetinal Cone Photoreceptor CellsFemaleArtificial intelligencebusinessColor PerceptionPhotic StimulationBiotechnologyPhotopic visionBiological Cybernetics
researchProduct

A method for determining precise electrical hearing thresholds in cochlear implant users

2018

A psychoacoustic procedure designed for the precise assessment of perceptional threshold (T-level) in cochlear implant (CI) users is presented. The impact of this procedure on speech perception was investigated.Individual T-level measurements were obtained with the proposed procedure and three different speech processor fitting conditions were applied: (1) fitting familiar to the subject, T-levels unchanged, (2) T-level set to thresholds determined with the new procedure, (3) T-level set to thresholds determined with the new procedure, but T-level is decreased by 10 clinical units (CU). The impact of the different fitting conditions was measured by means of categorical loudness scaling (CLS…

AdultMaleLinguistics and Languagemedicine.medical_specialtySpeech perceptiongenetic structuresComputer sciencemedicine.medical_treatmentDeafnessAudiologyLanguage and LinguisticsSpeech Reception Threshold TestYoung Adult03 medical and health sciencesSpeech and Hearing0302 clinical medicineCochlear implantotorhinolaryngologic diseasesmedicineHumansProspective StudiesPsychoacoustics030223 otorhinolaryngologyAgedSpeech Reception Threshold TestAuditory ThresholdMiddle AgedNoiseCochlear ImplantsSpeech PerceptionFemalesense organsNoise030217 neurology & neurosurgeryInternational Journal of Audiology
researchProduct

Endocrine response after cervical manipulation and mobilization in people with chronic mechanical neck pain: a randomized controlled trial

2019

BACKGROUND: Most of the research on the effects of spinal manipulation on endocrine function has been done on healthy subjects and has yielded contradictory results. The potential role of cervical manual therapy intervention in order to induce changes in the endocrine system has not yet been investigated. AIM: The aim of this trial is to compare the effects on salivary cortisol levels and clinical outcomes of cervical manipulation versus cervical mobilization or sham manipulation in patients with chronic mechanical neck pain. DESIGN: Randomized controlled trial. SETTING: University of Alcala de Henares: outpatient (referrals from office workers). POPULATION: A total of 83 patients with chro…

AdultMaleManipulation SpinalPain Threshold030506 rehabilitationHydrocortisonePopulationPhysical Therapy Sports Therapy and RehabilitationSpinal manipulationlaw.inventionDisability Evaluation03 medical and health sciences0302 clinical medicineRandomized controlled triallawThreshold of painHumansMedicineRange of Motion ArticularSalivaeducationPain MeasurementHydrocortisoneeducation.field_of_studyNeck painNeck Painbusiness.industryRehabilitationMiddle AgedAnesthesiaFemaleChronic PainManual therapymedicine.symptom0305 other medical sciencebusinessRange of motion030217 neurology & neurosurgerymedicine.drugEuropean Journal of Physical and Rehabilitation Medicine
researchProduct

The mid-difference hump in forward-masked intensity discrimination

2008

Forward-masked intensity-difference limens (DLs) for pure-tone standards presented at low, medium, and high levels were obtained for a wide range of masker-standard level differences. At a standard level of 25 dB SPL, the masker had a significant effect on intensity resolution, and the data showed a mid-difference hump: The DL elevation was greater at intermediate than at large masker-standard level differences. These results support the hypothesis that the effect of a forward masker on intensity resolution is modulated by the similarity between the masker and the standard. For a given masker-standard level difference, the effect of the masker on the DL was larger for a 55-dB SPL than for t…

AdultMaleMasking (art)medicine.medical_specialtyAcoustics and UltrasonicsDetection thresholdLoudness PerceptionAcousticsAudiologyLoudnessIntensity (physics)Intensity discriminationArts and Humanities (miscellaneous)Speech Discrimination TestsSpeech PerceptionmedicineHumansFemalePsychoacousticsPerceptual MaskingThe Journal of the Acoustical Society of America
researchProduct

Binaural release from masking in forward-masked intensity discrimination: Evidence for effects of selective attention

2012

In a forward-masked intensity discrimination task, we manipulated the perceived lateralization of the masker via variation of the interaural time difference (ITD). The maskers and targets were 500 Hz pure tones with a duration of 30 ms. Standards of 30 and 60 dB SPL were combined with 60 or 90 dB SPL maskers. As expected, the presentation of a forward masker perceived as lateralized to the other side of the head as the target resulted in a significantly smaller elevation of the intensity difference limen than a masker lateralized ipsilaterally. This binaural release from masking in forward-masked intensity discrimination cannot be explained by peripheral mechanisms because varying the ITD l…

AdultMaleMasking (art)medicine.medical_specialtySpeech recognitionInteraural time differenceMonauralAudiologybehavioral disciplines and activitiesLateralization of brain functionIntensity discriminationYoung AdultDiscrimination PsychologicalmedicineHumansAttentionSound LocalizationSelective attentionAuditory ThresholdSensory SystemsIntensity (physics)Acoustic StimulationAuditory PerceptionFemalePsychologyPerceptual MaskingBinaural recordingpsychological phenomena and processesPsychoacousticsHearing Research
researchProduct

Sequential grouping modulates the effect of non-simultaneous masking on auditory intensity resolution.

2012

The presence of non-simultaneous maskers can result in strong impairment in auditory intensity resolution relative to a condition without maskers, and causes a complex pattern of effects that is difficult to explain on the basis of peripheral processing. We suggest that the failure of selective attention to the target tones is a useful framework for understanding these effects. Two experiments tested the hypothesis that the sequential grouping of the targets and the maskers into separate auditory objects facilitates selective attention and therefore reduces the masker-induced impairment in intensity resolution. In Experiment 1, a condition favoring the processing of the maskers and the targ…

AdultMaleMasking (art)medicine.medical_specialtyTime FactorsCognitive NeuroscienceLoudness Perceptionmedia_common.quotation_subjectSpeech recognitionPerceptual Maskinglcsh:MedicineAudiologySocial and Behavioral Sciencesbehavioral disciplines and activitiesPitch DiscriminationBehavioral NeuroscienceYoung AdultCognitionPerceptionPsychophysicsmedicinePsychophysicsPsychologyHumansAttentionPsychoacousticsPitch Perceptionlcsh:ScienceBiologymedia_commonPhysicsMultidisciplinarylcsh:RExperimental PsychologyAuditory ThresholdSensory SystemsInterval (music)Auditory SystemAcoustic StimulationQUIETPitch DiscriminationSensory PerceptionFemalelcsh:QPerceptual Maskingpsychological phenomena and processesResearch ArticleNeurosciencePsychoacousticsPLoS ONE
researchProduct

Comparison of olfactory function in patients with seasonal and perennial allergic rhinitis

1998

Hyposmia is a common symptom in allergic rhinitis. However, little is known about differences in the olfactory function of patients with seasonal or perennial allergy. A prospective controlled study was performed on 28 patients with allergic rhinitis to grass pollen and on 47 patients with allergic rhinitis to mites. Sixty-six healthy volunteers served as a control. Olfactory function was evaluated by a modified Connecticut Chemosensory Clinical Research Center testing procedure for threshold, identification, and discrimination. The grass pollen-allergic patients were tested preseasonally and after 3 weeks of intraseasonal grass pollen exposure; the mite-allergic patients and the volunteers…

AdultMaleOlfactory systemAllergyRhinitis Allergic PerennialAdolescentImmunologyAnosmiaOlfactionDiscrimination PsychologicalHyposmiaotorhinolaryngologic diseasesMitemedicineOlfactory thresholdAnimalsHumansImmunology and AllergyProspective StudiesMitesbiologybusiness.industryRhinitis Allergic Seasonalfood and beveragesAllergensMiddle Agedbiology.organism_classificationmedicine.diseaseDiscrimination testingSmellImmunologyPollenFemalemedicine.symptombusinessAllergy
researchProduct

Lateralized and Bilateral Olfactory Function in Patients With Chronic Sinusitis Compared With Healthy Control Subjects

1998

Results of this study demonstrated that a new olfactory test, the "Sniffin' Sticks," can be used to distinguish hyposmic patients with chronic sinusitis (n = 63) from control subjects. Dirhinic testing yielded improved olfactory sensitivity compared with monorhinic testing. However, dirhinic results were not significantly different from results obtained for the best nostril.

AdultMaleOlfactory systemmedicine.medical_specialtyAdolescentNostrilNeurological disorderAudiologylaw.inventionRandomized controlled triallawSensory thresholdmedicineHumansIn patientSinusitisSinusitisAgedAged 80 and overbusiness.industryChronic sinusitismedicine.diseaseSurgerySmellmedicine.anatomical_structureOtorhinolaryngologySensory ThresholdsChronic DiseaseFemalebusinessThe Laryngoscope
researchProduct

Image quality and visual performance in the peripheral visual field following photorefractive keratectomy.

2002

ABSTRACT PURPOSE: A theoretical and experimental study was performed to assess the possible effects of photorefractive keratectomy (PRK) on retinal image quality and thresholds in the peripheral visual field. METHODS: Simple optical calculations suggest that although the quality of the retinal image at the fovea of the postoperative PRK eye may be comparable to that in an emmetropic eye, images in the peripheral field may be markedly worse, since peripheral ray bundles may pass partly through ablated and partly through unablated cornea, giving a simultaneous-vision bifocal effect. This would be expected to create an annular zone of confusion, so that light from two different directions in o…

AdultMaleOptics and Photonicsgenetic structuresmedicine.medical_treatmentVisual AcuityEmmetropiaPhotorefractive Keratectomychemistry.chemical_compoundCorneaMyopiaHumansMedicineVision OcularRetinabusiness.industryRetinaleye diseasesPhotorefractive keratectomyVisual fieldOphthalmologymedicine.anatomical_structureMeridian (perimetry visual field)chemistrySensory ThresholdsVisual Field TestsOptometryFemaleLasers ExcimerSurgerysense organsVisual FieldsbusinessPhotopic vision
researchProduct

Acute performance evaluation of a new ventricular automatic capture algorithm

2006

Aims This study evaluated the acute clinical performance of a new ventricular automatic capture algorithm developed to work with all lead types and pacing vectors. Methods and results During regular pacemaker implant or replacement, AutoThreshold and manual threshold tests were performed in ventricular unipolar (UP) and bipolar (BP, if applicable) pacing using a customized external prototype INSIGNIA™ pacemaker. The success rate and accuracy of two different modes (commanded and ambulatory) of the automatic capture algorithm were used to evaluate the performance. Loss-of-capture events (two consecutive non-captured beats without backup pacing) were used to assess safety. Data of 53 patients…

AdultMalePacemaker Artificialmedicine.medical_specialtyHeart VentriclesAbsolute thresholdlaw.inventionlawPhysiology (medical)Internal medicineHumansTelemetryMedicineProspective StudiesLead (electronics)AgedAged 80 and overbusiness.industrySignificant differenceClinical performancePacemaker implantMiddle AgedAmbulatoryElectrocardiography AmbulatoryCardiologyArtificial cardiac pacemakerFemaleCardiology and Cardiovascular MedicinebusinessAlgorithmAlgorithmsEP Europace
researchProduct