Search results for " Threshold"
showing 10 items of 497 documents
Verbesserte Auswertbarkeit transitorisch evozierter otoakustischer Emissionen durch Korrelationsfilterung
1993
Hearing screening as well as evaluation of cochlear function under therapy with ototoxic agents or patients with various diseases is increasingly done by registration of transient evoked otoacoustic emissions (TEOAE). Usually the standard system ILO 88 Otodynamic Analyser is used, where until now emissions were analyzed subjectively. However, evaluation of signals may be difficult mainly in the hearing threshold area. In this article we describe a method to mathematically analyze registered emissions by correlation-filtering. This allows to better identify small specific responses, to further increase the sensitivity of TEOAE, and offers a more objective means for audiologic diagnoses.
Experimental study on the effects of physical training on the defibrillation threshold
2011
Background: Chest compression artifacts during cardiopulmonary resuscitation (CPR) deteriorate the rhythm diagnosis of automated external defibrillators (AED). Cardiopulmonary resuscitation must therefore be interrupted for a reliable shock/no-shock decision. However, these hands-off intervals adversely affect the defibrillation success, and, in addition, pauses in chest compressions compromise circulation. An accurate diagnosis of the rhythmwhile performing CPR is therefore needed to minimize these hands-off intervals. Methods: The characteristics of the CPR artifact are very variable, and the artifact presents an important spectral overlap with human cardiac arrest rhythms. Consequently, …
The stability of color discrimination threshold determined using pseudoisochromatic test plates
2014
Congenital red-green color vision deficiency is one of the most common genetic disorders. A previously printed set of pseudoisochromatic plates (KAMS test, 2012) was created for individual discrimination threshold determination in case of mild congenital red-green color vision deficiency using neutral colors (colors confused with gray). The diagnostics of color blind subjects was performed with Richmond HRR (4th edition, 2002) test, Oculus HMC anomaloscope, and further the examination was made using the KAMS test. 4 male subjects aged 20 to 24 years old participated in the study: all of them were diagnosed with deuteranomalia. Due to the design of the plates, the threshold of every subject …
A fully automatic 2D segmentation method for uterine fibroid in MRgFUS treatment evaluation
2015
PurposeMagnetic Resonance guided Focused UltraSound (MRgFUS) represents a non-invasive surgical approach that uses thermal ablation to treat uterine fibroids. After the MRgFUS treatment, an operator must manually segment the treated fibroid areas to evaluate the NonPerfused Volume (NPV). This manual approach is operator-dependent, introducing issues of result reproducibility, which could lead to errors in the subsequent follow-up phase. Moreover, manual segmentation is time-consuming, and can have a negative impact on the optimization of both machine-time and operator-time. MethodTo address these issues, in this paper a novel fully automatic method based on the unsupervised Fuzzy C-Means cl…
Physical Condition Factors that Predict a Better Quality of Life in Women with Fibromyalgia
2019
What physical qualities can predict the quality of life (QoL) in women with fibromyalgia (FM)? QoL is a very complex outcome affected by multiple comorbidities in people with fibromyalgia. This study aims to determine which physical qualities can predict the quality of life in women with FM. Also, a comparison between the physical qualities of women with FM and healthy counterparts was conducted. In total, 223 women participated in this cross-sectional study, 123 with FM, with ages ranging between 45 and 70 years. The study was conducted at several fibromyalgia associations and specialized medical units. QoL was measured as the main outcome. In addition, functional capacity, muscular streng…
Otoacoustic emissions: a new method to diagnose hearing impairment in children.
1993
Otoacoustic emissions (OAEs) are epiphenomena of sensitive, amplifying processes during hearing which can be detected in persons with normal inner ear function. They originate from the cochlea and are interpreted as an energy leakage of cochlear processes, perhaps resulting from active outer hair cell movements. OAEs travel from the cochlea through the middle ear to the external auditory canal where they can be detected using sensitive miniature microphones. Transient evoked (TEOAE) tests allow to otoacoustic emissions non-invasively check the integrity of the cochlea. In the neonatal period, registration of OAEs can be accomplished during natural sleep. In infants and neonates TEOAEs can b…
Penicillin induced epileptiform activity and EEG spectrum analysis of BDNF heterozygous mice: an in vivo electrophysiological study.
2011
Brain-derived neurotrophic factor (BDNF) heterozygous mice (BDNF (+/-)) kindle slowly and have a higher seizure threshold. However, BDNF (+/-) mice exhibit reduced cortical inhibition and disrupted balance of excitation/inhibition synaptic transmission. We investigated penicillin-induced focal cortical epileptiform activity and electroencephalogram (EEG) spectral power of BDNF (+/-) mice, by using electrocorticogram (ECoG) recordings. BDNF (+/-) mice (n=10) and wild type littermates (n=9) were anesthetized with i.p. urethane (1.750g/kg). The recordings of ECoG were carried out by using a data acquisition system and 100IU penicillin was administered intracortically to induce epileptiform act…
Concordancia de las escalas REGICOR y SCORE para la identificación del riesgo cardiovascular alto en la población española
2007
Introduction. The aims of this study were to evaluate the consistency between the SCORE (Systematic Coronary Risk Evaluation) and REGICOR (Registre Gironi del Cor) scales in identifying high cardiovascular risk and to describe the characteristics of those individuals for whom scale results were discrepant. Methods. This cross-sectional study involved 8942 subjects aged 40-65 years who had an indication for a complete lipid profile. The agreement between SCORE (for low-risk countries) and Framingham-REGICOR (with a high risk threshold of 10%) scales in classifying patients as high risk was evaluated using the kappa statistic. Subjects for whom there was a discrepancy between classifications …
2018
Objective: High-intensity interval training (HIIT) can be extremely demanding and can consequently produce high blood lactate levels. Previous studies have shown that lactate is a potent metabolic stimulus, which is important for adaptation. Active recovery (ACT) after intensive exercise, however, enhances blood lactate removal in comparison with passive recovery (PAS) and, consequently, may attenuate endurance performance improvements. Therefore, the aim of this study was to examine the influence of regular ACT on training adaptations during a HIIT mesocycle. Methods: Twenty-six well-trained male intermittent sport athletes (age: 23.5 ± 2.5 years; O2max: 55.36 ± 3.69 ml min kg-1) participa…
Evaluation of the efficacy of the ‘nasal airflow-inducing manoeuvre’ for smell rehabilitation in laryngectomees by means of the Sniffin′ Sticks test
2011
Clin. Otolaryngol. 2011, 36, 17–23 Objective: To determine the efficacy of the nasal airflow-inducing manoeuvre (NAIM) as a method for olfactory rehabilitation in laryngectomees by the means of the Sniffin′ Sticks test. Study design: Prospective open interventional trial. Setting: Tertiary academic hospital. Participants: Thirty-seven patients after laryngectomy have been screened and 25 patients have been included into the study. The participant’s sense of smell was tested with the Sniffin′ Sticks test before and after learning the nasal airflow inducing manoeuvre. The individual level of threshold, discrimination and identification (TDI) was determined and the individual threshold, di…