Search results for " Time"

showing 10 items of 3005 documents

Criterion validity of two physical activity and one sedentary time questionnaire against accelerometry in a large cohort of adults and older adults

2020

ObjectivesWe compared the ability of physical activity and sitting time questionnaires (PAQ) for ranking individuals versus continuous volume calculations (physical activity level (PAL), metabolic equivalents of task (MET), sitting hours) against accelerometry measured physical activity as our criterion.MethodsParticipants in a cohort from the Tromsø Study completed three questionnaires; (1) The Saltin-Grimby Physical Activity Level Scale (SGPALS) (n=4040); (2) The Physical Activity Frequency, Intensity and Duration (PAFID) questionnaire (n=5902)) calculated as MET-hours·week-1 and (3) The International Physical Activity questionnaire (IPAQ) short-form sitting question (n=4896). We validate…

medicine.medical_specialtyMedicine (General)medicinePhysical activityphysical activityPhysical Therapy Sports Therapy and RehabilitationSittingMetabolic equivalent03 medical and health sciencessitting time0302 clinical medicineR5-920Criterion validityMedicineOrthopedics and Sports Medicine030212 general & internal medicine1506Sedentary timebusiness.industryOriginal research030229 sport sciencesVDP::Medisinske Fag: 700::Idrettsmedisinske fag: 850Physical activity levelaccelerometerQuartileCohortPhysical therapyepidemiologyVDP::Medical disciplines: 700::Sports medicine: 850business
researchProduct

2018

Beyond the classical paradigm that presents the Anticipatory Postural Adjustments (APAs) as a manner to create forces that counteract disturbances arising from the moving segment during a pointing task, there is a controversial discussion about the role APAs to facilitate the movement and perform a task accurately. In addition, arm kinematics features are classically used to infer the content of motor planning for the execution and the control of arm movements. The present study aimed to disentangle the conflicting role of APAs during an arm-pointing task in which the subjects reach a central diode that suddenly turns on, while their postural stability was manipulated. Three postures were a…

medicine.medical_specialtyMotor planningGeneral Neuroscience030229 sport sciencesGeneral MedicineKinematicsSittingGeneral Biochemistry Genetics and Molecular BiologyDeceleration time03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationPostural stabilitymedicineMotor planGeneral Agricultural and Biological SciencesPsychologypsychological phenomena and processes030217 neurology & neurosurgeryPeerJ
researchProduct

Objective measures of nasal function

1995

Numerous techniques to objectively measure nasal function are available to the rhinologic surgeon. Rhinomanometry, acoustic rhinometry, laser Doppler flowmetry, saccharin transport time, determination of ciliary beat frequency, and olfactory and trigeminal event-related potentials are all techniques in current use. Rhinomanometry is the standard clinical tool used to indicate those patients complaining of nasal obstruction who are likely to benefit from septal and turbinate surgery. Acoustic rhinometry permits the precise localization of nasal stenoses and is the best predictor of a patient's postoperative satisfaction. It is, in addition, more sensitive than rhinomanometry in recording cha…

medicine.medical_specialtyMucosal swellingmedicine.diagnostic_testbusiness.industryTransport timeBlood flowLaser Doppler velocimetryAcoustic rhinometryOtorhinolaryngologyOlfactory nerveOphthalmologyotorhinolaryngologic diseasesMedicineSurgeryRhinomanometrybusinessAirwayCurrent Opinion in Otolaryngology & Head and Neck Surgery
researchProduct

2014

Nonsimultaneous maskers can strongly impair performance in an auditory intensity discrimination task. Using methods of molecular psychophysics, we quantified the extent to which (1) a masker-induced impairment of the representation of target intensity (i.e., increase in internal noise) and (2) a systematic influence of the masker intensities on the decision variable contribute to these effects. In a two-interval intensity discrimination procedure, targets were presented in quiet, and combined with forward maskers. The lateralization of the maskers relative to the targets was varied via the interaural time difference. Intensity difference limens (DLs) were strongly elevated under forward mas…

medicine.medical_specialtyMultidisciplinarymedia_common.quotation_subjectPerceptual MaskingInteraural time differenceAudiologybehavioral disciplines and activitiesLateralization of brain functionIntensity (physics)QUIETPerceptionPsychophysicsmedicinePsychoacousticspsychological phenomena and processesMathematicsmedia_commonPLOS ONE
researchProduct

Annual Trends in Total Ischemic Time and One-Year Fatalities: The Paradox of STEMI Network Performance Assessment

2019

This study is aimed at assessing trends and relations between total ischemic time, the major quality measure of systemic delay, and case-fatality at the population or patient level in response to growing cardiovascular risk and a constant need to shorten the time to treatment in ST-segment elevation myocardial infarction (STEMI). Data from a prospective nationwide registry of STEMI patients admitted between 2006 and 2013 who were treated with primary percutaneous coronary intervention (PCI) were analyzed. Total ischemic time was calculated as the time from the onset of symptoms to primary PCI and was determined as individual and annual. The primary end-point was one-year, all-cause case-fat…

medicine.medical_specialtyMultivariate analysismedicine.medical_treatmentPopulationlcsh:MedicineIschemic time030204 cardiovascular system & hematologyArticleSTEMI03 medical and health sciencestotal ischemic time0302 clinical medicineInternal medicineCase fatality ratemedicinecase-fatality030212 general & internal medicineMyocardial infarctioncardiovascular diseasesRisk factoreducationeducation.field_of_studybusiness.industrylcsh:RPercutaneous coronary interventionGeneral Medicinemedicine.diseaseConventional PCInetworkCardiologybusinessJournal of Clinical Medicine
researchProduct

Laparoscopic versus robotic right colectomy with extra-corporeal or intra-corporeal anastomosis: a systematic review and meta-analysis.

2020

Purpose: The aim of the present systematic review and meta-analysis is to compare laparoscopic right colectomy (LRC) versus robotic right colectomy (RRC) using homogeneous subgroup analyses for extra-corporeal anastomosis (EA) and intra-corporeal anastomosis (IA). Methods: MEDLINE, Scopus, and Web of Science databases were searched up to April 2020 for prospective or retrospective studies comparing LRC versus RRC on at least one short- or long-term outcome. The primary outcome was the length of hospital stay (LOS). The secondary outcomes included operative and pathological results, survival, and total costs. LRC and RRC were compared using three homogeneous subgroups: without distinction by…

medicine.medical_specialtyOperative TimeAnastomosisRobotic right colectomy03 medical and health sciences0302 clinical medicineRobotic Surgical ProceduresmedicineExtra-corporeal anastomosis; Intra-corporeal anastomosis; Laparoscopic right colectomy; Meta-analysis; Robotic right colectomyHumansIntra-corporeal anastomosisProspective StudiesColectomyRetrospective Studiesbusiness.industryAnastomosis SurgicalRetrospective cohort studyVascular surgeryLength of StayCardiac surgerySurgeryLaparoscopic right colectomyExtra-corporeal anastomosisMeta-analysisTreatment OutcomeCardiothoracic surgery030220 oncology & carcinogenesisMeta-analysisRight Colectomy030211 gastroenterology & hepatologySurgeryLaparoscopybusinessAbdominal surgeryLangenbeck's archives of surgery
researchProduct

A Targeted Problem and Its Solution

1993

medicine.medical_specialtyOtorhinolaryngologyOtorhinolaryngologybusiness.industryGeneral surgeryMedicineReal time ultrasonographybusinessHead and neckSurgeryThe Laryngoscope
researchProduct

Are go/no-go tasks preferable to two-choice tasks in response time experiments with older adults?

2015

Epub ahead of print 02/11/2015 Recent research has shown that, in response time (RT) tasks, the go/no-go response procedure produces faster (and less noisy) RTs and fewer errors than the two-choice response procedure in children, although these differences are substantially smaller in college-aged adults. Here we examined whether the go/no-go procedure can be preferred to the two-choice procedure in RT experiments with older adults (i.e. another population with slower and more error-prone responding than college-aged individuals). To that end, we compared these response procedures in two experiments with older adults (Mage = 83 years): a visual word recognition task (lexical decision) and a…

medicine.medical_specialtyPSYCHOLOGY EXPERIMENTALLexical decisionmedia_common.quotation_subjectPopulationExperimental and Cognitive PsychologyAudiology050105 experimental psychologyTask (project management)PerceptionLexical decision taskmedicine0501 psychology and cognitive scienceseducationmedia_commonVisual word recognitioneducation.field_of_study05 social sciencesagingtask comparisonsResponse timeNumerosity adaptation effectGo/no goPsychologySocial psychology050104 developmental & child psychology
researchProduct

The Effect of Simulated Leg-Length Discrepancy on the Dynamic Parameters of the Feet during Gait—Cross-Sectional Research

2021

Background: The effect of Leg-Length Discrepancy (LLD) on dynamic gait parameters has been extensively discussed. Podobarography is the study of foot-to-ground pressure distribution. It has been used to test plantar footprint deviations that could reveal pathology. Purpose: The aim of this study is to determine the effects of simulated LLD on dynamic gait parameters measured with a pressure platform in healthy subjects. Methods: Thirty-seven healthy subjects participated in observational cross-sectional research. A procedure was performed to capture the dynamic parameters of each participant under five different simulated LLD conditions. Support time, mean pressure, and peak pressure measur…

medicine.medical_specialtyPasoLeadership and ManagementCross-sectional studyLeg length inequalityLeg Length Inequalityleg length inequalityHealth InformaticsgaitArticleLower limb03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationHealth Information ManagementInfermeriaMiembro inferiorpressure platformmedicinereliability analysisGaitFisioterapiaAnálisis de fiabilidad030222 orthopedicsPreassure platformbusiness.industryHealth PolicyLeg lengthRRepeated measures designDesigualdad en la longitud de las piernasGaitlower limbsPlataforma de presiónPodologíaMedicineAnalysis of variancebusinessReliability analysisStance time030217 neurology & neurosurgeryFoot (unit)Healthcare
researchProduct

Effects of intermittent high frequency electrical stimulation on denervated EDL muscle of rabbit.

1990

This study was performed to determine whether electrical stimulation can retard denervation-induced changes. The denervated extensor digitorum longus of the rabbit, a fast-twitch muscle, was stimulated at a rate mimicking its motoneuron firing pattern. The 100-Hz stimulation given intermittently subjected the muscle to a low mean total daily frequency of 1.6 Hz. Four weeks of stimulation resulted in no effect upon the denervated stimulated muscle. This stimulation protocol, therefore, is unable to substitute for the lost neuronal influence of the nerve. The muscle contralateral to the stimulated side showed physiological changes making it unsuitable to serve as a control.

medicine.medical_specialtyPhysiologyStimulationCellular and Molecular NeuroscienceAtrophyPhysiology (medical)Internal medicinemedicineAnimalsDenervationContraction timeLagomorphabiologyChemistryElectromyographyMusclesAnatomymusculoskeletal systembiology.organism_classificationmedicine.diseaseAmyotrophyElectric StimulationMuscle DenervationMuscular AtrophyEndocrinologyNeurology (clinical)RabbitsMuscle ContractionMusclenerve
researchProduct