Search results for " ToM"
showing 10 items of 1742 documents
Linear and Volumetric Mandibular Asymmetries in Adult Patients With Different Skeletal Classes and Vertical Patterns: A Cone-Beam Computed Tomography…
2018
AbstractThis study aimed to quantify the height of the mandibular condyle and ramus, condylar volume, and the asymmetry index in adult patients of different sex, skeletal class and vertical pattern using Cone-Beam Computed Tomography (CBCT), and to determine whether there were differences between these groups. The study used CBCT scans of 159 patients with a mean age of 32.32 ± 8.31 years. InVivoDental® software was used to perform both linear (condylar, ramal, and total height) and condylar volume measurements. Linear and volumetric asymmetries were calculated. There were not significant differences between right and left sides. The mean value obtained for condyle height was 7.27 mm, ramus…
A retrospective radiographic evaluation of the anterior loop of the mental nerve: Comparison between panoramic radiography and cone beam computerized…
2014
Objectives: To compare the prevalence and the length of mental loop, measured with panoramic radiography (PR) and cone beam computerized tomography (CBCT). Material and Methods: PG and CBCT images where analyzed by a single calibrated examiner to determine the presence and the position of the mental foramen (MF), its distance to the lower mandible border, the anterior length of the mental loop (ML) and the bone quality in 82 PR and 82 CBCT. Results: ML was identified in 36.6 % of PR and 48.8 % of CBCT. PR showed a magnification of 1.87 when compared to CBCT. The mean of anterior extension of the inferior alveolar nerve and the distance to the inferior border of the mandible was higher for P…
Three-dimensional cone-beam computed tomography for diagnosis of keratocystic odontogenic tumours; evaluation of four cases.
2011
The keratocystic odontogenic tumour (KCOT), formerly known as the odontogenic keratocyst (OKC) is a benign intraosseous lesion that derives from remnants of the dental lamina. Due to its characteristics, clinical and histopathological features and various treatment approaches, this pathology is different comparing with other odontogenic cysts. Radiographically the KCOT appears as well-defined unilocular or multilocular radiolucency with thin radiopaque borders. In most cases, conventional radiographic imaging, such as panoramic views and intraoral periapical films, are adequate to determine the location and estimate the size of an KCOT. However, the clinical use for cone-beam computed tomog…
Implant treatment planning regarding augmentation procedures: panoramic radiographs vs. cone beam computed tomography images.
2015
Objectives To evaluate the impact of cone beam computed tomography (CBCT) imaging on treatment planning regarding augmentation procedures for implant placement. Material and methods Panoramic radiographs and CBCT images of 40 patients requesting single-tooth implants in 59 sites were retrospectively analyzed by six specialists in implantology, and treatment planning was performed. Therapeutic recommendations were compared with the surgical protocol performed initially. Results Bone height estimation from panoramic radiographs yielded to higher measures and greater variability compared to CBCT. The suggested treatment plan for lateral and vertical augmentation procedures based on CBCT or pan…
Computed tomography coronary angiography in asymptomatic patients
2011
This study assessed the accuracy of computed tomography coronary angiography (CT-CA) for detecting significant coronary artery disease (CAD; a parts per thousand yen50% lumen reduction) in intermediate/high-risk asymptomatic patients. A total of 183 consecutive asymptomatic individuals (92 men; mean age 54 +/- 11 years) with more than one major risk factor (obesity, hypertension, diabetes, hypercholesterolaemia, family history, smoking) and an inconclusive or nonfeasible noninvasive stress test result (stress electrocardiography, stress echocardiography, nuclear stress scintigraphy) underwent CT-CA in an outpatient setting. All patients underwent conventional coronary angiography (CAG) with…
High Iodine Concentration Contrast Material for Noninvasive Multislice Computed Tomography Coronary Angiography
2006
OBJECTIVE: The objective of this study was to compare intracoronary attenuation on 16-row multislice computed tomography (16-MSCT) coronary angiography using 2 contrast materials (CM) with high iodine concentration. MATERIAL AND METHODS: Forty consecutive patients (29 male, 11 female; mean age, 61 ± 11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL; Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy). Both CM were administered at a rate of 4 mL/s. All patients underwent 16-MSCT coronary angiography (Sensation 16; …
Staging of osteonecrosis of the jaw requires computed tomography for accurate definition of the extent of bony disease
2014
AbstractManagement of osteonecrosis of the jaw associated with antiresorptive agents is challenging, and outcomes are unpredictable. The severity of disease is the main guide to management, and can help to predict prognosis. Most available staging systems for osteonecrosis, including the widely-used American Association of Oral and Maxillofacial Surgeons (AAOMS) system, classify severity on the basis of clinical and radiographic findings. However, clinical inspection and radiography are limited in their ability to identify the extent of necrotic bone disease compared with computed tomography (CT). We have organised a large multicentre retrospective study (known as MISSION) to investigate th…
Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Cohere…
2016
To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 periph…
Dopamine D2/3 receptor occupancy by quetiapine in striatal and extrastriatal areas
2010
Quetiapine is next to clozapine an antipsychotic agent that exerts hardly any extrapyramidal side-effects at clinical efficacious doses. Some previous receptor occupancy studies reported preferential extrastriatal D2/3 receptor (D2/3R)-binding properties of second-generation antipsychotics and suggested this as possible reason for improved tolerability. This positron emission tomography (PET) investigation was designed to compare the occupancy of dopamine D2/3Rs by quetiapine in striatal and extrastriatal brain regions. Therefore, a cohort of 16 quetiapine-treated psychotic patients underwent an [18F]fallypride (FP) PET scan. Due to the high affinity of FP and its comparatively long half-li…
Ventral striatal prediction error signaling is associated with dopamine synthesis capacity and fluid intelligence.
2012
Fluid intelligence represents the capacity for flexible problem solving and rapid behavioral adaptation. Rewards drive flexible behavioral adaptation, in part via a teaching signal expressed as reward prediction errors in the ventral striatum, which has been associated with phasic dopamine release in animal studies. We examined a sample of 28 healthy male adults using multimodal imaging and biological parametric mapping with 1) functional magnetic resonance imaging during a reversal learning task and 2) in a subsample of 17 subjects also with positron emission tomography using 6-[18F]fluoro-L-DOPA to assess dopamine synthesis capacity. Fluid intelligence was measured using a battery of nine…