Search results for " Tom"
showing 10 items of 1742 documents
Asymmetry in dopamine D2/3 receptors of caudate nucleus is lost with age
2007
Molecular and functional imaging techniques reveal evidence for lateralization of human cerebral function. Based on animal data, we hypothesized that asymmetry in dopamine neurotransmission declines during normal aging. In order to test this hypothesis, we measured dopamine D2/3 receptor availability with [18F]desmethoxyfallypride-PET (DMFP) in putamen and caudate nucleus (NC) of 21 healthy, right-handed males (24-60 years; 35+/-10). For volumetric analysis, high-resolution T1-weighted MR-images were obtained in 18 of the PET-subjects in order to assess possible age-related decreases in NC and putamen volume. The calculated DMFP binding potentials (BP) showed a right-ward asymmetry in NC of…
Central correlation of muscle sympathetic nerve activation during baroreflex unloading - a microneurography-positron emission tomography study
2013
The baroreceptor reflex controls spontaneous fluctuations in blood pressure. One major control variable of the baroreflex is the sympathetic vasoconstrictor activity to muscles [MSNA; burst frequency (BF) and burst incidence (BI)], which can be quantitatively assessed by microneurography. We aimed to investigate the central regions involved in baroreflex regulation of MSNA. Healthy men (mean age 25 years) participated in three experimental sessions. (i) Microneurography recordings of MSNA from the left peroneal nerve during rest and baroreflex unloading, induced by lower body negative pressure (LBNP; -40 mmHg). If MSNA could be reliably recorded throughout this procedure (n = 15), the subje…
Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.
2020
To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …
Differential contributions of ankle plantarflexors during submaximal isometric muscle action: A PET and EMG study
2014
Abstract The objective of this study was to investigate the relative contributions of superficial and deep ankle plantarflexors during repetitive submaximal isometric contractions using surface electromyography (SEMG) and positron emission tomography (PET). Myoelectric signals were obtained from twelve healthy volunteers (27.3±4.2yrs). A tracer ([ 18 F]-FDG) was injected during the exercise and PET scanning was done immediately afterwards. The examined muscles included soleus (Sol), medial gastrocnemius (MG), lateral gastrocnemius (LG), and flexor hallucis longus (FHL). It was found that isometric maximal voluntary contraction (MVC) force, muscle glucose uptake (GU) rate, and SEMG of variou…
Use of autologous tooth-derived graft material in the post-extraction dental socket. Pilot study
2019
Background The objectives of the present pilot study are to compare via CBCT the alveolar contraction suffered both vertically and horizontally between the control group and the group using autologous dental material (ADM), as well as to study the densitometric differences between both post-extraction sockets. Material and Methods A split-mouth study was performed in n = 9 patients who required two extraction of single-rooted teeth deemed suitable for deferred rehabilitation with osseointegrated implants. Two groups were formed — a control group, in which the post-extraction socket was not filled, and an ADM group, in which the alveolar defect was filled with freshly processed autogenous de…
Somatostatin-receptor scintigraphy in Graves' disease: reproducibility and variance of orbital activity.
2000
Somatostatin-receptor (SSTR) scintigraphy using the single photon emission computed tomography (SPECT) technique allows the assessment of orbital inflammation in patients with Graves' disease. Previous studies showed differences in orbital octreotide uptake already 4 hr after injection. In this study, analysis of inter-/intra-observer variance and reproducibility in the evaluation of orbital SPECT images was performed. First, SPECT data of one representative female patient with clinically active Graves' ophthalmopathy (GO), obtained 4 hr after intravenous injection of 110 MBq 111In-pentetreotide and processed by filtered backprojection, were analyzed. Transverse SPECT images were reconstruc…
Pneumonia in Febrile Neutropenic Patients and in Bone Marrow and Blood Stem-Cell Transplant Recipients: Use of High-Resolution Computed Tomography
1999
PURPOSE: To obtain statistical data on the use of high-resolution computed tomography (HRCT) for early detection of pneumonia in febrile neutropenic patients with unknown focus of infection. MATERIALS AND METHODS: One hundred eighty-eight HRCT studies were performed prospectively in 112 neutropenic patients with fever of unknown origin persisting for more than 48 hours despite empiric antibiotic treatment. Fifty-four of these studies were performed in transplant recipients. All patients had normal chest roentgenograms. If pneumonia was detected by HRCT, guided bronchoalveolar lavage was recommended. Evidence of pneumonia on chest roentgenograms during follow-up and micro-organisms detected…
[18F]5-fluoro-2-deoxyuridine-PET for imaging of malignant tumors and for measuring tissue proliferation
2003
The nucleoside 5-fluoro-2-deoxyuridine is a pyrimidine analogue accumulating in proliferative cells. We prospectively evaluated biodistribution of the PET tracer [(18)F]5-fluoro-2-deoxyuridine (FdUrd), its value for imaging malignant tumors, and its correlation to both [(18)F]2-fluoro-2-deoxyglucose (FDG)-PET findings and histological proliferation indices. In 11 previously untreated patients (5 lung carcinoma; 3 soft tissue sarcoma; 2 gastrointestinal carcinoma; 1 non-Hodgkin lymphoma [NHL]), mean doses of 290 MBq FdUrd and 390 MBq FDG were administered intravenously on subsequent days. Static PET scans were initiated 50-70 min after administration and the mean standardized uptake values (…
High opiate receptor binding potential in the human lateral pain system
2005
To determine how opiate receptor distribution is co-localized with the distribution of nociceptive areas in the human brain, eleven male healthy volunteers underwent one PET scan with the subtype-nonselective opioidergic radioligand [(18)F]fluoroethyl-diprenorphine under resting conditions. The binding potential (BP), a parameter for the regional cerebral opioid receptor availability, was computed using the occipital cortex as reference region. The following regions of interest (ROIs) were defined on individual MR images: thalamus, sensory motor strip (SI/MI area), frontal operculum, parietal operculum, anterior insular cortex, posterior insular cortex, anterior cingulate cortex (ACC; peri-…
Accuracy between virtual surgical planning and actual outcomes in orthognathic surgery by iterative closest point algorithm and color maps: A retrosp…
2018
Background To evaluate the accuracy between actual outcomes and virtual surgical planning (VSP) in orthognathic surgery regarding the use of three-dimensional (3D) surface models for registration using iterative closest point (ICP) algorithm and generated color maps. Material and Methods Construction of planning and postoperative 3D models in STL files format (M0 and M1, respectively) from CBCT of 25 subjects who had been submitted to bimaxillary orthognathic surgery was performed. M0 and M1 were sent to Geomagic software in semi-automatic alignment surface mesh order of M0 and M1 for registration using ICP algorithm to calculate mean deviation (MD, MD+, MD-, SD) and root mean square (RMS –…