Search results for " Tom"
showing 10 items of 1742 documents
New Trends in Detectors for Medical Imaging
2010
The improvement of medical imaging instrumentation is based both on the enhancement of the performance of the detectors employed in their construction and on the development of novel techniques and methods that allow full exploitation of the advantages of the new instrumentation.
Relevance of functional imaging in dental implantology
2018
Background Despite it is widely used in many medicine fields, the use of functional imaging to examine dental implants has not been reported in the literature. This work aimed to evaluate the relevance of functional medical imaging in oral implantology. Material and methods This single-center observational study was conducted for 6 months at the Toulouse University Hospital, France. All patients who underwent positron emission tomography with 18-fluorodeoxyglucose integrated with X-ray computed tomography (FDG PET/CT) and had dental implants were included. Metabolic activity of the peri-implant tissues was assessed qualitatively and quantitatively jointly by a nuclear physician and a dental…
Effects of diet-induced obesity and voluntary wheel running on the microstructure of the murine distal femur
2011
Abstract Background Obesity and osteoporosis, two possibly related conditions, are rapidly expanding health concerns in modern society. Both of them are associated with sedentary life style and nutrition. To investigate the effects of diet-induced obesity and voluntary physical activity we used high resolution micro-computed tomography (μCT) together with peripheral quantitative computed tomography (pQCT) to examine the microstructure of the distal femoral metaphysis in mice. Methods Forty 7-week-old male C57BL/6J mice were assigned to 4 groups: control (C), control + running (CR), high-fat diet (HF), and high-fat diet + running (HFR). After a 21-week intervention, all the mice were sacrifi…
Automatic scanning of large tissue areas in neurosurgery using optical coherence tomography
2012
Background With its high spatial and temporal resolution, optical coherence tomography (OCT) is an ideal modality for intra-operative imaging. One possible application is to detect tumour invaded tissue in neurosurgery, e.g. during complete resection of glioblastoma. Ideally, the whole resection cavity is scanned. However, OCT is limited to a small field of view (FOV) and scanning perpendicular to the tissue surface. Methods We present a new method to use OCT for scanning of the resection cavity during neurosurgical resection of brain tumours. The main challenges are creating a map of the cavity, scanning perpendicular to the surface and merging the three-dimensional (3D) data for intra-ope…
Molecular imaging of gastroenteropancreatic neuroendocrine tumors.
2010
Somatostatin-receptor scintigraphy has become an obligatory molecular imaging method in the management of patients with neuroendocrine tumors when metastatic disease is suspected. Using positron emission tomography and new somatostatin analogues, sensitivity of somatostatin receptor imaging has further increased. With a combination of morphologic imaging methods, such as hybrid imaging by PET/CT, this method represents the method of choice in many centers and efforts are under way to translate somatostatin receptor imaging onto a cellular level by endoscopic confocal microscopy. Other clinically relevant functional pathways in neuroendocrine tumors that are accessible by PET imaging are glu…
Hepatic Sinusoidal Dilatation: A Review of Causes With Imaging-Pathologic Correlation.
2016
Hepatic sinusoids are vascular conduits connecting the portal triad with the central vein. Multiple conditions can lead to sinusoidal dilatation and congestion with resultant stasis of blood within the lumen. The altered hemodynamics associated with hepatic sinusoidal dilatation generally result in heterogeneous enhancement of the hepatic parenchyma on contrast-enhanced computed tomography and magnetic resonance imaging, a pattern often described as “mosaic” enhancement. In this article, we review the causes of hepatic sinusoidal dilatation and the imaging manifestations on contrast-enhanced computed tomography and magnetic resonance.
Common and uncommon pitfalls in pancreatic imaging: it is not always cancer.
2015
Despite advances in multimodality imaging of pancreas, there is still overlap between imaging findings of several pancreatic/peripancreatic disease processes. Pancreatic and peripancreatic non-neoplastic entities may mimic primary pancreatic neoplasms on ultrasound, CT, and MRI. On the other hand, primary pancreatic cancer may be overlooked on imaging because of technical and inherent factors. The purpose of this pictorial review is to describe and illustrate pancreatic imaging pitfalls and highlight the basic radiological features for proper differential diagnosis.
Darmkontrastierung bei der abdominellen Computertomographie: Wasser oder Kontrastmittel?
1991
The suitability of water as an oral or rectal contrast medium for abdominal CT was studied in 56 patients and compared with an iodine-containing water-soluble contrast medium (ioxital amino acid). In some cases it was impossible to differentiate gastrointestinal structures from extraluminal fluid collections (cystic tumours, ascites, abscesses) and there was poor filling of distal small bowel and colon. The routine use of water can, therefore, not be recommended. In some cases, however, water can result in improved image quality by reducing artifacts and improving the demonstration of the mucosa.
6-18F-Fluoro-l-Dihydroxyphenylalanine Positron Emission Tomography Is Superior to123I-Metaiodobenzyl-Guanidine Scintigraphy in the Detection of Extra…
2010
Context: Pheochromocytomas (PHEOs) and paragangliomas (PGLs) may be better detected by 18F-fluorodihydroxyphenylalanine-positron emission tomography (FDOPA-PET) than 123I-metaiodobenzyl-guanidine (123-I-MIBG) scintigraphy. Objective: The objective of the study was to correlate functional imaging results with immunohistochemical, molecular-genetic, and biochemical findings. Design and Setting: Thirty consecutive patients with suspected PHEO/PGL presenting at a tertiary referral centre were investigated in a prospective study. Patients: Twenty-five patients had confirmed PHEO/PGL. Thirteen of 25 patients had a hereditary PHEO/PGL syndrome (two multiple endocrine neoplasia II, six succinate de…