Search results for " Total"
showing 10 items of 385 documents
Channel Tracking Guidewire and Technique for Retrograde Approach
2020
Evaluation of the collateral circulation is critical for determining the feasibility of the retrograde approach. When assessing collateral channels it is of paramount importance to take time and review the previous angiogram carefully, for multiple potential collateral pathways, as the predominant collateral may change over time prior to the procedure. Careful review of collaterals prior to the procedure can reduce contrast and radiation dose as well as the duration of the procedure.Retrograde access to the distal vessel can be achieved via septal collaterals, epicardial collaterals (atrial channel), or (patent or occluded) coronary bypass grafts. Generally septals are used more often 65–70…
Atmospheric compensation in Fourier transform infrared (FT-IR) spectra of clinical samples.
2013
A new method is proposed for the elimination of the spectral contribution of two atmospheric gases (CO2 and H2O) in Fourier transform infrared (FT-IR) spectra of clinical samples. The algorithm is based on the measurement of reference spectra of H2O followed by an automatic calculation of the spectral contribution of the above-mentioned gases to the sample spectra. Then this contribution is compensated by spectral subtraction. Attenuated total reflectance FT-IR spectra of serum and urine samples in the presence of atmospheric gases were corrected and compared with spectra obtained with an N2 purge. Visual inspection of the spectra as well as calculated noise levels confirmed that the metho…
Electrosynthesis of Poly(alanine)-Like Peptides in Concentrated Alanine Based Electrolytes, Characterization Coupled to DFT Study and Application to …
2014
The anodic oxidation of concentrated l-alanine on smooth electrodes such as platinum and glassy carbon electrodes was studied. Contrary to the previous studies performed up to now with diluted l-alanine, the electrochemical process generated here results in a completely different situation. The oxidation on smooth platinum was carried out by electrochemical quartz crystal microbalance (EQCM) coupled to cyclic voltammetry technique. The effects of concentration, scan rate, and pH (zwitterion at pH = 6 and alkaline media at pH = 13) on potential values were examined. Glassy carbon and smooth gold electrodes showed the same behavior as on smooth platinum electrode. Spectroscopic analysis such …
Evaluation of infrared spectroscopy as a screening tool for serum analysis
2013
Abstract The application of attenuated total reflectance Fourier transform infrared (ATR-FT-IR) spectroscopy to the determination of clinical parameters in serum using partial least squares (PLS) has been evaluated as a point-of-care diagnostic tool. In this study the effect of using an increased size of the calibration set and the influence of the origin of samples and their interyear variation on the prediction capability of the method were considered. PLS-ATR-FT-IR provides a green, fast and cheap point-of-care tool for the determination of total protein. Albumin, glucose, urea, HDL, LDL and total cholesterol were predicted with relative errors between 15 and 32%. The analytical predicti…
Untersuchungen zur Ver�nderung des Gehaltes von Cholesterin, Gesamtlipid und Lipid-P im Serum von Ratten nach F�tterung von oxydierten Soja�len
1962
Partial least squares attenuated total reflectance IR spectroscopy versus chromatography: the greener method
2012
Method election is a complex task that must be done carefully in order to ensure the capability of analytical methodologies to provide appropriate data for problem solving. This is a real challenge in all fields, but especially with bioanalysis, which in many cases involves the need to do a large number of determinations in complex
Fast authentication of tea tree oil through spectroscopy
2018
Two new procedures, based on infrared spectroscopy in the near infrared (NIR) and mid infrared (MIR), have been developed for the authentication of tea tree oil (TTO) commercial samples. Infrared measurements were made on untreated samples by transmission NIR and attenuated total reflectance (ATR) followed by partial least square discriminant analysis (PLS-DA). These methods offer a fast and low cost alternative to enantiomeric two-dimensional gas chromatography coupled to mass detection usually employed to discriminate between authentic and non-authentic samples. In these studies, a set of 267 samples, including authentic and non-authentic labelled tea tree oil samples, were used to build …
Comparison of two vibrational procedures for the direct determination of mancozeb in agrochemicals.
2007
The direct determination of mancozeb in agrochemicals has been made by diamond attenuated total reflectance (ATR) Fourier transform infrared spectroscopy in the middle range (DATR-MIR) and diffuse reflectance infrared Fourier transform spectroscopy in the near range (DR-NIR) methods using in both cases a previous identification of the samples using a dendrographic classification and an appropriate partial least squares (PLS) calibration established from a set of nine external standards and optimized for each type of sample. It was analyzed a heterogeneous population of 11 samples obtained from the Spanish market, containing different co-formulated products, such as fosetyl-Al, copper oxychl…
Essential oil counterfeit identification through middle infrared spectroscopy
2018
Abstract Infrared spectroscopy (FTIR) has been employed for a fast quality control of commercial essential oils from different plant species. 47 samples were obtained from Algerian and Spanish market and directly measured, without any previous treatment, by attenuated total reflectance Fourier transform Infrared spectroscopy (ATR-FTIR), in the wavenumber region between 4000 and 550 cm−1. Pure essential oils were obtained by hydro- and steam-distillation extraction methods and their ATR spectra obtained. Results found evidenced the presence of solvents in some commercial formulations and permitted a rapid authentication of pure essential oils correctly extracted from those diluted. The propo…
Origin based classification of crude oils by infrared spectrometry and chemometrics
2019
Abstract Crude oil samples from different Iranian petrol resources in both, raw and mixture forms have been characterized by attenuated total reflectance mid infrared spectroscopy. Obtained spectra were classified by chemometric techniques to propose a method for geological based classification of crude oil samples. Totally 251 samples from 7 petrol fields and 3 mixtures were analyzed. Mean centering and principal component analysis (PCA) supported – leverage value based outlier detection were used as preprocessing approaches. PCA, cluster analysis and soft independent modeling of class analogy (SIMCA) were utilized to classify the spectra. Obtained results confirmed that SIMCA is a robust …