Search results for " Ultraviolet"
showing 10 items of 337 documents
RAPID SENSING OF VOLCANIC SO2 FLUXES USING A DUAL ULTRAVIOLET CAMERA SYSTEM: NEW TECHNIQUES AND MEASUREMNETS AT SOUTHERN ITALIAN VOLCANOES.
2012
Relationship between erythemal UV and broadband solar irradiation at high altitude in Northwestern Argentina
2018
An analysis of the broadband solar irradiation, IT, and the erythemal UV irradiation, IUVER, has been performed using the measurements made from 2013 to 2015 at three sites located at altitudes over 1000 m a.s.l. In Northwestern Argentina (Salta, El Rosal, and Tolar Grande). The main objective of this paper is to determine a relationship between IT and IUVER, which would allow to estimate IUVER from IT in places with few IUVER measurements available, and especially in those where is important to establish adequate photoprotection measures given their dense population and location at high altitude. The relationship between the daily values of IUVER and IT has been fitted to a linear regressi…
Photoemission microscopy with microspot-XPS by use of undulator radiation and a high-throughput multilayer monochromator at BESSY
1999
We present a new experiment for photoelectron microspectroscopy by use of undulator radiation, which has been set up at the beamline U2 at the Berlin electron storage ring BESSY 1. This approach employs a non-imaging simulated hemispherical electron energy analyser attached to an imaging photoemission electron microscope (FOCUS IS-PEEM) with integrated microarea selector. The photoemission microscope exhibits a lateral resolution of 25 nm (with 4.9 eV UV-excitation), while the resolution with incident synchrotron radiation in the soft X-ray range is about 100-120 nm (mainly due to chromatic aberrations). Photoemission microscopy as well as photoelectron microspectroscopy of selected areas o…
Laser driven parametric amplification in the xuv and soft-x-ray spectral range
2011
We present the first experimental realization of a new x-ray laser scheme based on strong-field parametric amplification of high-order harmonic radiation. With a simple semi-classical model, we can identify the most important experimental parameters, the spectral range and the small signal gain in gases. Using a single amplifier stage a small signal gain of 8000 has been obtained in Argon for the spectral range of 40-50 eV, using 350 fs, 7 mJ pulses at 1.05 µm. In Helium, we observed a small signal gain of 280 around 300 eV using 6 fs, 1.5 mJ pulses at 800 nm.
Two-color ionization of hydrogen by short intense pulses
2010
Photoelectron energy spectra resulting by the interaction of hydrogen with two short pulses having carrier frequencies, respectively, in the range of the infrared and XUV regions have been calculated. The effects of the pulse duration and timing of the X-ray pulse on the photoelectron energy spectra are discussed. Analysis of the spectra obtained for very long pulses show that certain features may be explained in terms of quantum interferences in the time domain. It is found that, depending on the duration of the X-ray pulse, ripples in the energy spectra separated by the infrared photon energy may appear. Moreover, the temporal shape of the low frequency radiation field may be inferred by …
Tuning the high-order harmonic lines of a Nd:Glass laser for soft x-ray laser seeding
2010
Taking advantage of the non-adiabatic blue-shift of high-order harmonics generated by a fixed frequency Nd:Glass laser system, we are able to report more than 50 % coverage of the XUV spectral range between 18 nm and 35 nm. The generated harmonic lines are capable of seeding Ni-like Y, Zr and Mo soft x-ray lasers and others.
Stable and long-time operation of a soft x-ray laser for user applications experiments
2011
LASERIX is a high-power laser facility leading to High-repetition-rate XUV laser pumped by Titanium:Sapphire laser. The aim of this laser facility is to offer Soft XRLs in the 30-7 nm range and auxiliary IR beam that could also be used to produce synchronized XUV sources. This experimental configuration highly enhances the scientific opportunities of the facility, giving thus the opportunity to realize both X-ray laser experiments and more generally pump/probe experiments, mixing IR and XUV sources. In this contribution, the main results concerning both the development of XUV sources(X-Ray lasers and HHG sources) and their use for applications are presented.
Use of triacylglycerol profiles established by high performance liquid chromatography with ultraviolet–visible detection to predict the botanical ori…
2011
A method for the determination of triacylglycerols (TAGs) in vegetable oils from different botanical origins by HPLC with UV–vis detection has been developed. Using a core-shell particle packed column (C18, 2.6 micron), TAG separation was optimized in terms of mobile phase composition and column temperature. Using isocratic elution with acetonitrile/n-pentanol at 10 °C, excellent efficiency with good resolution between most of the TAG peak pairs, within a total analysis time of 15 min, was achieved. Using mass spectrometry detection, a total of 15 peaks, which were common to oils of six different botanical origins (corn, extra virgin olive, grapeseed, hazelnut, peanut and soybean) were iden…
High-performance liquid chromatographic separation of modified and native melittin following transglutaminase-mediated derivatization with a dansyl f…
1991
Abstract The 26-amino acid linear, amphiphilic peptide melittin was enzymatically modified with the fluorescent probe monodansylcadaverine using guinea pig liver transglutaminase and a fluorescent derivative of stoichiometry 1:1 was obtained. Reversed-phase and size-exclusion high-performance liquid chromatographic modes were tested in order to resolve the labelled peptide and native species. The influence of several operational variables was analysed and the elution conditions were optimized so that a satisfactory resolution could be achieved in both instances in a rapid, easy manner. Both chromatographic modes offer the possibility of accurate monitoring of the time course of the enzyme-m…
Determination of liposoluble vitamins in cooked meals, milk and milk products by liquid chromatography
2002
A method for the simultaneous determination of liposoluble vitamins in cooked meals was established. Saponification was performed with 50% (w/v) KOH at 80 degrees C, and ascorbic acid was added as antioxidant. The subsequent extraction was carried out with diethyl ether. This was followed by a liquid chromatographic separation on a reversed-phase C18 column with methanol-water (94:6, v/v as the mobile phase. Retinyl acetate was used as the internal standard. The analytical parameters linearity, detection limit (0.19 and 8.33 microg/100 g for retinol and alpha-tocopherol, respectively), precision of the method (RSD=5.24 and 6.99% for retinol and alpha-tocopherol, respectively) and recovery a…