Search results for " Ultraviolet"

showing 10 items of 337 documents

RAPID SENSING OF VOLCANIC SO2 FLUXES USING A DUAL ULTRAVIOLET CAMERA SYSTEM: NEW TECHNIQUES AND MEASUREMNETS AT SOUTHERN ITALIAN VOLCANOES.

2012

RAPID SENSING OF VOLCANIC SO2 FLUXESNEW TECHNIQUES AND MEASUREMNETS AT SOUTHERN ITALIAN VOLCANOES.DUAL ULTRAVIOLET CAMERA SYSTEMSettore GEO/08 - Geochimica E Vulcanologia
researchProduct

Relationship between erythemal UV and broadband solar irradiation at high altitude in Northwestern Argentina

2018

An analysis of the broadband solar irradiation, IT, and the erythemal UV irradiation, IUVER, has been performed using the measurements made from 2013 to 2015 at three sites located at altitudes over 1000 m a.s.l. In Northwestern Argentina (Salta, El Rosal, and Tolar Grande). The main objective of this paper is to determine a relationship between IT and IUVER, which would allow to estimate IUVER from IT in places with few IUVER measurements available, and especially in those where is important to establish adequate photoprotection measures given their dense population and location at high altitude. The relationship between the daily values of IUVER and IT has been fitted to a linear regressi…

Radiació solar010504 meteorology & atmospheric sciencesPopulationOtras Ciencias de la Tierra y relacionadas con el Medio AmbienteSolar zenith angle010501 environmental sciencesAtmospheric sciences01 natural sciencesIndustrial and Manufacturing EngineeringCiencias de la Tierra y relacionadas con el Medio AmbienteSOUTHERN HEMISPHEREAltitudeLinear regressionIrradiationHIGH ALTITUDEElectrical and Electronic EngineeringBROADBAND SOLAR IRRADIATIONERYTHEMAL ULTRAVIOLET IRRADIATIONeducationSouthern Hemisphere0105 earth and related environmental sciencesCivil and Structural Engineeringeducation.field_of_studyMultivariable linear regressionMechanical EngineeringRadiació ultravioladaBuilding and ConstructionEffects of high altitude on humansCLEARNESS INDICESPollutionGeneral EnergyEnvironmental scienceCIENCIAS NATURALES Y EXACTAS
researchProduct

Photoemission microscopy with microspot-XPS by use of undulator radiation and a high-throughput multilayer monochromator at BESSY

1999

We present a new experiment for photoelectron microspectroscopy by use of undulator radiation, which has been set up at the beamline U2 at the Berlin electron storage ring BESSY 1. This approach employs a non-imaging simulated hemispherical electron energy analyser attached to an imaging photoemission electron microscope (FOCUS IS-PEEM) with integrated microarea selector. The photoemission microscope exhibits a lateral resolution of 25 nm (with 4.9 eV UV-excitation), while the resolution with incident synchrotron radiation in the soft X-ray range is about 100-120 nm (mainly due to chromatic aberrations). Photoemission microscopy as well as photoelectron microspectroscopy of selected areas o…

RadiationMaterials scienceMicroscopeEUV multilayer opticsbusiness.industryExtreme ultraviolet lithographySynchrotron radiationUndulatorGratingCondensed Matter Physicsmicroarea XPSAtomic and Molecular Physics and Opticsphotoemission microscopyElectronic Optical and Magnetic Materialslaw.inventionOpticsX-ray photoelectron spectroscopylawBlazed gratingPhysical and Theoretical ChemistrybusinessSpectroscopyMonochromator
researchProduct

Laser driven parametric amplification in the xuv and soft-x-ray spectral range

2011

We present the first experimental realization of a new x-ray laser scheme based on strong-field parametric amplification of high-order harmonic radiation. With a simple semi-classical model, we can identify the most important experimental parameters, the spectral range and the small signal gain in gases. Using a single amplifier stage a small signal gain of 8000 has been obtained in Argon for the spectral range of 40-50 eV, using 350 fs, 7 mJ pulses at 1.05 µm. In Helium, we observed a small signal gain of 280 around 300 eV using 6 fs, 1.5 mJ pulses at 800 nm.

Range (particle radiation)ArgonMaterials sciencebusiness.industryAmplifierchemistry.chemical_elementLaserOptical parametric amplifierlaw.inventionOpticschemistrylawExtreme ultravioletbusinessHeliumParametric statistics
researchProduct

Two-color ionization of hydrogen by short intense pulses

2010

Photoelectron energy spectra resulting by the interaction of hydrogen with two short pulses having carrier frequencies, respectively, in the range of the infrared and XUV regions have been calculated. The effects of the pulse duration and timing of the X-ray pulse on the photoelectron energy spectra are discussed. Analysis of the spectra obtained for very long pulses show that certain features may be explained in terms of quantum interferences in the time domain. It is found that, depending on the duration of the X-ray pulse, ripples in the energy spectra separated by the infrared photon energy may appear. Moreover, the temporal shape of the low frequency radiation field may be inferred by …

Range (particle radiation)Materials scienceAtomic Physics (physics.atom-ph)InfraredSettore FIS/01 - Fisica SperimentaleFOS: Physical sciencesPulse durationPhoton energyCondensed Matter PhysicsSettore FIS/03 - Fisica Della MateriaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Industrial and Manufacturing EngineeringAtomic and Molecular Physics and OpticsSpectral linePhysics - Atomic PhysicsPulse (physics)Condensed Matter - Other Condensed MatterIonizationExtreme ultravioletAtomic physicsMultiphoton ionization atomic interactions with photonsInstrumentationOther Condensed Matter (cond-mat.other)Laser Physics
researchProduct

Tuning the high-order harmonic lines of a Nd:Glass laser for soft x-ray laser seeding

2010

Taking advantage of the non-adiabatic blue-shift of high-order harmonics generated by a fixed frequency Nd:Glass laser system, we are able to report more than 50 % coverage of the XUV spectral range between 18 nm and 35 nm. The generated harmonic lines are capable of seeding Ni-like Y, Zr and Mo soft x-ray lasers and others.

Range (particle radiation)Materials sciencebusiness.industryNonlinear opticsLaserlaw.inventionOpticslawHarmonicsExtreme ultravioletHarmonicHigh harmonic generationSeedingbusinessSPIE Proceedings
researchProduct

Stable and long-time operation of a soft x-ray laser for user applications experiments

2011

LASERIX is a high-power laser facility leading to High-repetition-rate XUV laser pumped by Titanium:Sapphire laser. The aim of this laser facility is to offer Soft XRLs in the 30-7 nm range and auxiliary IR beam that could also be used to produce synchronized XUV sources. This experimental configuration highly enhances the scientific opportunities of the facility, giving thus the opportunity to realize both X-ray laser experiments and more generally pump/probe experiments, mixing IR and XUV sources. In this contribution, the main results concerning both the development of XUV sources(X-Ray lasers and HHG sources) and their use for applications are presented.

Range (particle radiation)Soft x rayMaterials sciencebusiness.industryLaserlaw.inventionX-ray laserOpticslawExtreme ultravioletSapphireOptoelectronicsHigh harmonic generationbusinessBeam (structure)SPIE Proceedings
researchProduct

Use of triacylglycerol profiles established by high performance liquid chromatography with ultraviolet–visible detection to predict the botanical ori…

2011

A method for the determination of triacylglycerols (TAGs) in vegetable oils from different botanical origins by HPLC with UV–vis detection has been developed. Using a core-shell particle packed column (C18, 2.6 micron), TAG separation was optimized in terms of mobile phase composition and column temperature. Using isocratic elution with acetonitrile/n-pentanol at 10 °C, excellent efficiency with good resolution between most of the TAG peak pairs, within a total analysis time of 15 min, was achieved. Using mass spectrometry detection, a total of 15 peaks, which were common to oils of six different botanical origins (corn, extra virgin olive, grapeseed, hazelnut, peanut and soybean) were iden…

Resolution (mass spectrometry)Analytical chemistrymedicine.disease_causeMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySpectrophotometrymedicinePlant OilsChromatography High Pressure LiquidTriglyceridesPacked bedBOTANICAL ORIGINIsocratic elutionChromatographymedicine.diagnostic_testChemistryOrganic ChemistryDiscriminant Analysisfood and beveragesGeneral MedicineTRIACYLGLYCEROLSLINEAR DISCRIMINANT ANALYSISPhase compositionSpectrophotometry UltravioletHPLCVEGETABLE OILSUltravioletJournal of Chromatography A
researchProduct

High-performance liquid chromatographic separation of modified and native melittin following transglutaminase-mediated derivatization with a dansyl f…

1991

Abstract The 26-amino acid linear, amphiphilic peptide melittin was enzymatically modified with the fluorescent probe monodansylcadaverine using guinea pig liver transglutaminase and a fluorescent derivative of stoichiometry 1:1 was obtained. Reversed-phase and size-exclusion high-performance liquid chromatographic modes were tested in order to resolve the labelled peptide and native species. The influence of several operational variables was analysed and the elution conditions were optimized so that a satisfactory resolution could be achieved in both instances in a rapid, easy manner. Both chromatographic modes offer the possibility of accurate monitoring of the time course of the enzyme-m…

Resolution (mass spectrometry)Tissue transglutaminaseGuinea PigsMolecular Sequence DataPeptideBiochemistryMelittinAnalytical Chemistrychemistry.chemical_compoundCadaverineAmphiphileAnimalsAmino Acid SequenceDerivatizationChromatography High Pressure Liquidchemistry.chemical_classificationDansyl CompoundsChromatographyTransglutaminasesbiologyChemistryElutionOrganic ChemistryGeneral MedicineFluorescenceMelittenSpectrometry Fluorescencebiology.proteinChromatography GelSpectrophotometry UltravioletJournal of chromatography
researchProduct

Determination of liposoluble vitamins in cooked meals, milk and milk products by liquid chromatography

2002

A method for the simultaneous determination of liposoluble vitamins in cooked meals was established. Saponification was performed with 50% (w/v) KOH at 80 degrees C, and ascorbic acid was added as antioxidant. The subsequent extraction was carried out with diethyl ether. This was followed by a liquid chromatographic separation on a reversed-phase C18 column with methanol-water (94:6, v/v as the mobile phase. Retinyl acetate was used as the internal standard. The analytical parameters linearity, detection limit (0.19 and 8.33 microg/100 g for retinol and alpha-tocopherol, respectively), precision of the method (RSD=5.24 and 6.99% for retinol and alpha-tocopherol, respectively) and recovery a…

Retinyl acetateSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundAnimalsDetection limitChromatographyOrganic ChemistryExtraction (chemistry)RetinolReproducibility of Resultsfood and beveragesVitaminsGeneral MedicineAscorbic acidLipidsMilkSolubilitychemistrySpectrophotometry UltravioletDairy ProductsDiethyl etherSaponificationChromatography LiquidJournal of Chromatography A
researchProduct