Search results for " Uncertainty"

showing 10 items of 777 documents

Effects of Lévy noise on the dynamics of sine-Gordon solitons in long Josephson junctions

2015

We numerically investigate the generation of solitons in current-biased long Josephson junctions in relation to the superconducting lifetime and the voltage drop across the device. The dynamics of the junction is modelled with a sine-Gordon equation driven by an oscillating field and subject to an external non-Gaussian noise. A wide range of $\alpha$-stable L\'evy distributions is considered as noise source, with varying stability index $\alpha$ and asymmetry parameter $\beta$. In junctions longer than a critical length, the mean switching time (MST) from superconductive to the resistive state assumes a values independent of the device length. Here, we demonstrate that such a value is direc…

PhysicsJosephson effectStatistics and ProbabilityCondensed Matter - SuperconductivityDynamics (mechanics)large deviations in non-equilibrium systemsLarge deviations in non-equilibrium systems; mesoscopic systems (theory); metastable states; stochastic processes (theory); Statistics and Probability; Statistical and Nonlinear Physics; Statistics Probability and UncertaintyStatistical and Nonlinear Physicsstochastic processes (theory)metastable state01 natural sciencesSettore FIS/03 - Fisica Della Materia010305 fluids & plasmasLevy noiseQuantum mechanicsLarge deviations in non-equilibrium systemmesoscopic systems (theory)Condensed Matter::Superconductivitymetastable states0103 physical scienceslarge deviations in non-equilibrium systems; mesoscopic systems (theory); metastable states; stochastic processes (theory)SineStatistics Probability and Uncertainty010306 general physicsStatistical and Nonlinear Physic
researchProduct

Precision measurement of two iodine lines at 585 nm and 549 nm

1993

The transition frequencies of thei-component of the R(99)15-1 and thew-component of the R(85)26-0 transition in the B-X system of molecular127I2 have been determined with an overall relative standard uncertainty of 1.3 · 10−10. For this purpose a commercial linear dye laser has been modified and stabilized to the corresponding iodine line. This dye laser serves as a transportable frequency standard which is compared with the wavelength standards of the PTB. The evaluation of an experiment for testing special relativity at the test storage ring (TSR) in Heidelberg is based on the precision of the reported interferometric wavelength comparison.

PhysicsNuclear and High Energy PhysicsDye laserbusiness.industryOther Fields of Physicschemistry.chemical_elementFrequency standardIodineWavelengthInterferometryOpticschemistryStandard uncertaintybusinessStorage ringLine (formation)Zeitschrift f�r Physik A Hadrons and Nuclei
researchProduct

The binding energy of 184 476 X in the droplet model

1985

The positron spectrum emitted in the U-U-reaction at subthreshold energy could be interpreted in terms of the formation of a giant nucleus if the binding of the latter is 100 MeV stronger than predicted by the usual droplet model parametrisation. We analyse the extrapolation to giant nuclei by accounting properly for the error propagation when the parameters are fitted to measured binding energies and radii. The influence of higher order terms is discussed.

PhysicsNuclear and High Energy PhysicsPropagation of uncertaintySubthreshold conductionNuclear TheoryBinding energyExtrapolationmedicine.anatomical_structurePositronmedicineNuclear fusionAtomic physicsNuclear ExperimentNucleusZeitschrift f�r Physik A Atoms and Nuclei
researchProduct

Uncertainty propagation within the UNEDF models

2016

The parameters of the nuclear energy density have to be adjusted to experimental data. As a result they carry certain uncertainty which then propagates to calculated values of observables. In the present work we quantify the statistical uncertainties of binding energies, proton quadrupole moments, and proton matter radius for three UNEDF Skyrme energy density functionals by taking advantage of the knowledge of the model parameter uncertainties. We find that the uncertainty of UNEDF models increases rapidly when going towards proton or neutron rich nuclei. We also investigate the impact of each model parameter on the total error budget.

PhysicsNuclear and High Energy PhysicsPropagation of uncertaintyWork (thermodynamics)ProtonNuclear Theory010308 nuclear & particles physicsuncertainty quantificationBinding energyNuclear TheoryFOS: Physical sciencesObservableRadius114 Physical sciences01 natural sciences7. Clean energyNuclear Theory (nucl-th)Skyrme energy density functional0103 physical sciencesQuadrupoleNeutronStatistical physics010306 general physicsNuclear Experimenterror propagation
researchProduct

Reactor neutrino background at the proposed LAGUNA sites

2012

Abstract The electron antineutrino background from reactors is estimated in proposed LAGUNA sites using commercial fission reactors operational in 2009. Calculations are made for an input to background studies like e.g. geoneutrino measurement uncertainty estimation.

PhysicsNuclear physicsNuclear and High Energy PhysicsParticle physicsFissionGeoneutrinoUnderground laboratoryMeasurement uncertaintyReactor neutrinoNeutrino oscillationElectron neutrinoAtomic and Molecular Physics and OpticsNuclear Physics B - Proceedings Supplements
researchProduct

Energy loss measurement of protons in liquid water

2011

The proton stopping power of liquid water was, for the first time, measured in the energy range 4.7-15.2 MeV. The proton energies were determined by the time-of-flight transmission technique with the microchannel plate detectors, which were especially developed for timing applications. The results are compared to the literature values (from ICRU Report 49 (1993) and Janni's tabulation (1982 At. Data Nucl. Data Tables 27 147-339)) which are based on Bethe's formula and an agreement is found within the experimental uncertainty of 4.6%. Thus, earlier reported discrepancy between the experimental and literature stopping power values at lower energies was not observed at the energies considered …

PhysicsRange (particle radiation)Energy lossTime FactorsRadiological and Ultrasound TechnologyProtonLiquid waterDetectorWaterNuclear physicsExperimental uncertainty analysisSolventsStopping power (particle radiation)Computer SimulationLinear Energy TransferRadiology Nuclear Medicine and imagingMicrochannel plate detectorProtonsAtomic physicsRadiometryPhysics in Medicine and Biology
researchProduct

Reduction of the uncertainty in the measurements of magnetic fields

2014

The paper deals with magnetic field measurement, carried out by using a broadband and isotropic instrument. These measurements are characterized by a very high uncertainty values if compared with the ones usually related to other electrical measurements. For these reasons, if the measurements are performed to assess the exposure of human beings, these large uncertainty values imply a high risk of wrong decision when there is the need to establish if a site complies or does not comply with a specified emission limits. A reduction of the uncertainty values implies a reduction of the risk. With this aim, we propose an approach which, in particular but very typical cases, allows an effective re…

PhysicsSustainability and the EnvironmentMagnetoresistancebusiness.industrymagnetic field measurementsIsotropyElectrical engineeringmeasurement uncertainty.Magnetic fieldReduction (complexity)Control theorymagnetic field measurementmeasurement uncertaintyCalibrationSettore ING-IND/09 - Sistemi per l'Energia e L'AmbienteMeasurement uncertaintyElectrical measurementsRenewable EnergyInstrumentation (computer programming)businessSettore ING-INF/07 - Misure Elettriche E Elettronichemagnetic field measurements; measurement uncertainty; Renewable Energy Sustainability and the Environment2014 International Conference on Renewable Energy Research and Application (ICRERA)
researchProduct

Response to “Comment on ‘Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brac…

2016

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyThermal ionizationGeneral Medicine030218 nuclear medicine & medical imagingComputational physics03 medical and health sciences0302 clinical medicineLow energy030220 oncology & carcinogenesisIonizationCalibrationmedicineMeasurement uncertaintyDosimetryNuclear medicinebusinessMedical Physics
researchProduct

1997

We have determined by forced Rayleigh scattering the diffusion coefficients of photo-labeled polystyrene micronetwork spheres (radii ≤ 10 nm) in melts of linear polyvinylmethylether (M W ≤ 40000 g/mol) at temperatures of 20-80°C. An expected slippage of the spheres through the meshes of the entanglement network appears possible but is still within the experimental uncertainty of our results.

Polymers and PlasticsGeneral Chemical EngineeringThermodynamicsCondensed Matter::Soft Condensed Matterchemistry.chemical_compoundMolten statesymbols.namesakeExperimental uncertainty analysischemistryPolymer chemistrysymbolsForced Rayleigh scatteringSPHERESPolystyreneSlippageDiffusion (business)Rayleigh scatteringActa Polymerica
researchProduct

Statistical Analysis of a Method to Predict Drug–Polymer Miscibility

2015

In this study, a method proposed to predict drug-polymer miscibility from differential scanning calorimetry measurements was subjected to statistical analysis. The method is relatively fast and inexpensive and has gained popularity as a result of the increasing interest in the formulation of drugs as amorphous solid dispersions. However, it does not include a standard statistical assessment of the experimental uncertainty by means of a confidence interval. In addition, it applies a routine mathematical operation known as "transformation to linearity," which previously has been shown to be subject to a substantial bias. The statistical analysis performed in this present study revealed that t…

PolymersChemistry PharmaceuticalPharmaceutical Science02 engineering and technology030226 pharmacology & pharmacyMiscibility03 medical and health sciences0302 clinical medicineMinimum-variance unbiased estimatorPredictive Value of TestsStatisticsStatistical inferenceApplied mathematicsMathematicsCalorimetry Differential ScanningFelodipineTemperatureLinear modelEstimatorModels Theoretical021001 nanoscience & nanotechnologyConfidence intervalTransformation (function)Experimental uncertainty analysisPharmaceutical PreparationsSolubilityLinear ModelsThermodynamics0210 nano-technologyAlgorithmsJournal of Pharmaceutical Sciences
researchProduct