Search results for " Volume"

showing 10 items of 1162 documents

Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

2009

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …

AdultMaleFluid responsivenessBlood PressureAutomationMonitoring IntraoperativeAbdomenMedicineHumansIn patientPulseAgedObserver VariationBlood Volumebusiness.industryAirway ResistanceLimits of agreementReproducibility of ResultsMiddle AgedReference StandardsPulse pressureAnesthesiology and Pain MedicineBlood pressureData Interpretation StatisticalRespiratory MechanicsFemalebusinessAlgorithmAlgorithmsAnesthesia and analgesia
researchProduct

MR imaging of the heart in patients after myocardial infarction: effect of increasing intersection gap on measurements of left ventricular volume, ej…

1999

International audience; Abstract: PURPOSE: To determine the extent to which the number of planes imaged at magnetic resonance (MR) imaging could be reduced without modifying the volume and thickness of the left ventricle. MATERIALS AND METHODS: Sixty-one patients were examined after a myocardial infarction. The whole left ventricle was imaged by using 5-mm contiguous breath-hold cine MR short-axis sections with no gap (SA(ng)) (two-dimensional fast low-angle shot sequence, 9/4.8 [repetition time msec/echo time msec]). The effect of omitting in two (short-axis sections with 5-mm gap [SA(5mm)]) or two sections in three(short-axis sections with 10-mm gap [SA(10mm)]) was studied. RESULTS: In th…

AdultMaleHeart Ventriclesvolume measurementinfarction[INFO.INFO-IM] Computer Science [cs]/Medical ImagingMyocardial InfarctionInfarctionheart030204 cardiovascular system & hematologyIntersection (Euclidean geometry)030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansRadiology Nuclear Medicine and imagingMyocardial infarctionejection fractionAgedAged 80 and overvolumeEjection fractionmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryventriclesMyocardiumMagnetic resonance imagingStroke VolumeStroke volumeMRMiddle Agedmedicine.diseaseMagnetic Resonance Imagingmedicine.anatomical_structureVentricleEnd-diastolic volumeFemalebusinessNuclear medicinemagnetic resonance (MR)cine studyRadiology
researchProduct

Respiratory Mechanics, Gastric Insufflation Pressure, and Air Leakage of the Laryngeal Mask Airway

1997

A potential risk of the laryngeal mask airway (LMA) is incomplete mask seal, which causes air leakage or insufflation of air into the stomach. The objective of the present study was to assess respiratory mechanics, quantify air leakage, and measure gastric air insufflation in patients ventilated via the LMA. Thirty patients were studied after induction of anesthesia but prior to any surgical manipulations. After the insertion of the LMA, patients were ventilated with increasing tidal volumes until one of the three following end points were reached: 1) gastric air insufflation, 2) airway pressure > 40 cm H2O, or 3) limitation of further increase in tidal volume by air leakage. The following …

AdultMaleInsufflationLeakAdolescentRespiratory physiologyLaryngeal MasksLaryngeal mask airwayPressureTidal VolumemedicineHumansRespiratory systemTidal volumebusiness.industryStomachStomachInsufflationMiddle Agedrespiratory systemRespiration Artificialmedicine.anatomical_structureAnesthesiology and Pain MedicineAnesthesiaRespiratory MechanicsFemalebusinessAirwayAnesthesia & Analgesia
researchProduct

Volumetry of Ventilated Airspaces by 3He MRI

2001

To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…

AdultMaleIsotopesImage Processing Computer-AssistedHumansFemaleRadiology Nuclear Medicine and imagingGeneral MedicineLung Volume MeasurementsHeliumMagnetic Resonance ImagingInvestigative Radiology
researchProduct

Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study

2019

AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …

AdultMaleLeakmedicine.medical_specialtylcsh:MedicineSettore MED/41 - AnestesiologiaPressure support ventilationTherapeuticsRespiratory physiologyManikinsArticlePositive-Pressure Respiration03 medical and health sciences0302 clinical medicineInternal medicineHealthy volunteersTidal VolumemedicineHumanslcsh:SciencePositive end-expiratory pressureTidal volumeMouthpieceVentilators Mechanicalacute respiratory failureMultidisciplinarybusiness.industrylcsh:RhelmetReproducibility of Resultsnoninvasive ventilation030208 emergency & critical care medicineEquipment DesignHealthy Volunteers030228 respiratory systemPreclinical researchRespiratory MechanicsCardiologyFeasibility Studieslcsh:QFemaleHead Protective DevicesNoninvasive ventilationbusinessScientific Reports
researchProduct

“Anatomical” versus “Territorial” Belonging of the Middle Hepatic Vein: Virtual Imaging and Clinical Repercussions

2011

Background Venous drainage patterns are of vital importance in live donor liver transplantation. The purpose of this study was to delineate “anatomical-topographical” and “territorial-physiologic” patterns of the middle hepatic vein (MHV) in a 3-D liver model as determined by the Pringle line and its drainage volume of the right and left hemilivers. Methods One hundred thirty-seven consecutive live donor candidates were evaluated by 3-D CT reconstructions and virtual hepatectomies. Based on right (R) and left (L), anatomical (A) and territorial (T) belonging patterns of the MHV, each individual was assigned to one of four possible types: type I:AR–TR; type II:AL–TL; type III:AR–TL; type IV:…

AdultMaleLive donormedicine.medical_treatmentMedizinLiver transplantationHepatic VeinsDrainage volumeImaging Three-DimensionalVenous congestionmedicineLiving DonorsHepatectomyHumansVirtual imagingbusiness.industryVenous drainageAnatomyPhlebographyAnatomy RegionalMiddle AgedLiver TransplantationLiverRight hemiliverSurgeryFemaleLiving donor liver transplantationbusinessTomography X-Ray ComputedLiver Circulation
researchProduct

Transthoracic three-dimensional echocardiographic volumetry of distorted left ventricles using rotational scanning

1997

The purpose of this study was to evaluate the relation of transthoracic three- and two-dimensional echocardiographic left ventricular volumetry to cineventriculographic volumetry. Twenty-five patients with distorted left ventricles were included in the study. To demonstrate the impact of acquiring data by rotational scanning, we performed three- and two-dimensional echocardiography in 36 latex ventricles with data acquisition in different areas of the ultrasound sectors. Interobserver and intraobserver variability were calculated to test for reproducibility. The three-dimensional imaging system consisted of a rotation motor device, a transthoracic 2.5 MHz transducer, a conventional ultrasou…

AdultMaleModels Anatomicmedicine.medical_specialtyCardiac VolumeHeart VentriclesCardiac VolumeLeft VentriclesConventional ultrasoundRoot mean squareImage Processing Computer-AssistedHumansMedicineRadiology Nuclear Medicine and imagingAgedObserver VariationReproducibilitybusiness.industryUltrasoundReproducibility of ResultsMiddle AgedTransducermedicine.anatomical_structureVentricleRegression AnalysisFemaleRadiologyCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealJournal of the American Society of Echocardiography
researchProduct

Measurement of end-tidal carbon dioxide in spontaneously breathing patients in the pre-hospital setting. A prospective evaluation of 350 patients

2002

Monitoring of end-tidal carbon dioxide (EtCO(2)) is good clinical practice in the patient who is intubated and ventilated. This study investigated the EtCO(2) values in spontaneously breathing patients treated in a physician-staffed mobile intensive care unit (MICU). This article also discusses whether EtCO(2) monitoring may have an influence on therapeutic decisions by emergency physicians by providing additional information.Over a period of 6 months, 350 spontaneously breathing patients (162 males, 137 females) were treated and transported in our MICU and monitored using a LifePak 12 monitor (EtCO(2), respiratory rate, pO(2), blood pressure, heart rate). Only 299 were enrolled in the stud…

AdultMaleNarcoticsArtificial ventilationEmergency Medical ServicesSubarachnoid hemorrhageAdolescentRespiratory ratemedicine.medical_treatmentAmbulancesEmergency Nursinglaw.inventionSeizureslawHumansMedicineProspective StudiesTidal volumeAgedAged 80 and overbusiness.industryGlasgow Coma ScaleCarbon DioxideMiddle AgedSubarachnoid Hemorrhagemedicine.diseaseIntensive care unitAsthmaHypoglycemiaBlood pressureAnesthesiaEmergency MedicineBreathingFemaleCardiology and Cardiovascular MedicinebusinessResuscitation
researchProduct

Bone quality in the midpalate for temporary anchorage devices.

2009

Objective The aim of the present study was to quantitatively assess the bone quality of the palatal bone from an implantologic standpoint. Material and methods The material consisted of palatal tissue blocks of autopsy material from 22 subjects (19 male, three female), between 18 and 63 years of age. The specimens comprised the anterior part of median palate (APMP) from about 7 mm behind the incisive foramen (first premolar regions), the middle part of median palate (MPMP, second premolar region), and the posterior part of the median palate (PPMP, first molar region). They were prepared in the transversal plane using ground-thin-section technology. The midpalatal areas of the different part…

AdultMalePalate HardYounger ageBone densityAdolescentDentistryHard tissueMandibular first molarYoung AdultBone DensityBone Marrowparasitic diseasesBone qualityPremolarmedicineCadaverOrthodontic Anchorage ProceduresHumansIncisive foramenDental Implantsbusiness.industryAge FactorsCranial SuturesMiddle Agedmedicine.anatomical_structureFemaleOral SurgerybusinessBone volumeClinical oral implants research
researchProduct

High-frequency oscillatory ventilation and an interventional lung assist device to treat hypoxaemia and hypercapnia

2004

A male patient accidentally aspirated paraffin oil when performing as a fire-eater. Severe acute respiratory distress syndrome ( P a 2 / F 2 ratio 10.7 kPa) developed within 24 h. Conventional pressure-controlled ventilation (PCV) with high airway pressures and low tidal volumes failed to improve oxygenation. Hypercapnia ( P a 2 12 kPa) with severe acidosis (pH<7.20) ensued. Treatment with high-frequency oscillatory ventilation (HFOV) and a higher adjusted airway pressure (35 cm H2O) improved the P a 2 / F 2 ratio within 1 h from 10.7 to 22.9 kPa, but the hypercapnia and acidosis continued. Stepwise reduction of the mean airway pressure (26 cm H2O), and oscillating frequencies (3.5 Hz), as …

AdultMalePartial Pressuremedicine.medical_treatmentHigh-Frequency VentilationMean airway pressureHypercapniaExtracorporeal Membrane OxygenationmedicineHumansHypoxiaTidal volumeAcidosisRespiratory Distress Syndromebusiness.industryHigh-frequency ventilationOxygenationrespiratory systemrespiratory tract diseasesOxygenAnesthesiology and Pain MedicineParaffinAnesthesiaBreathingmedicine.symptombusinessAirwayOilsHypercapniaBritish Journal of Anaesthesia
researchProduct