Search results for " Wear"
showing 10 items of 111 documents
Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.
2020
OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…
Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Pati…
2020
Background and objectives: To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator®
The Bronze Age burials from Cova Dels Blaus (Vall d′Uixó, Castelló, Spain): An approach to palaeodietary reconstruction through dental pathology, occ…
2005
This paper reports a palaeodietary investigation of the human remains found in the collective Bronze Age burial cave from Vall d'Uixó (Castelló, Spain). Dental pathology, tooth wear as well as buccal dental microwear were analysed. Percentages of dental pathologies were compared with Chalcolithic and Bronze Age sites from the same territory. Dental caries, ante-mortem tooth loss, periodontal disease and abscess frequencies indicate a diet rich in carbohydrate foods. However, dental calculus percentages and macroscopic wear patterns suggest a diet not exclusively relying on agricultural resources. In addition, buccal dental microwear density and length by orientation recorded on micrographs …
Adherence to growth hormone (GH) therapy in naïve to treatment GH-deficient children: data of the Italian Cohort from the Easypod Connect Observation…
2019
Background: With the use of non-objective measurement, adherence to growth hormone (GH) therapy has been reported suboptimal in a large proportion of patients, and poor adherence has been shown to affect short-term growth response in patients receiving GH treatment. Objective: The Easypod™ electronic device allows objective measurement of adherence. In this study, we report 3-year prospective adherence data of the Italian cohort of naïve GH deficient (GHD) children extrapolated from the Easypod Connect Observational Study (ECOS) database. Patients and methods: Seventy-three GHD children naïve to GH treatment were included in the analysis. 22 Italian centers participated in the study. Result…
Metal Matrix Composites - Mmc - Turning: Comparison of Tool Materials
2002
The main properties required to the modem cutting tools to be employed in production, are both high wear resistance and chemical stability. In this last years, in the machining of MMCs several kinds of coated tools have been developed; they are characterized by high hardness to resist to the relevant strength and abrasive action of the reinforce fibers or particles, arranged inside the matrix. In turning of MMC the employ of Tungsten Carbide tools coated with Polycrystalline Diamond (PCD) have shown to be very effective, whereas they are very expensive thus increasing the production costs.
Prediction of Tool Wear Progress in Machining of Carbon Steel using different Tool Wear Mechanismsl
2008
In this paper the prediction of tool wear on carbide uncoated tools was taken into account. In particular, two different tool wear models based on the diffusion mechanism and on the abrasion mechanism were considered. The calibration of the utilized models was done using the results obtained by experimental analysis performed on an orthogonally machined AISI 1020 tube. Once the calibration was executed, numerical simulations, for both the utilized tool wear models, were simultaneously performed with the aim to test the capability of the proposed numerical procedure. The comparison between the two tool wear mechanisms for predicting the flank tool wear is discussed in the paper.
Recrystallization in subsurface zone seen by positron annihilation
2010
Abstract The paper presents studies of the defect distribution, detected by the positron annihilation method in the subsurface zone (SZ) of copper samples after dry sliding wear. It takes advantage of a new experimental technique based on scanning of the positron implantation profile. It allowed us to detect the defect profile in copper to the depth of 200 μm in a nondestructive way and study isochronal annealing behavior of this profile. We determined that annealing induces a recrystallization process which runs faster close to the surface than in deeper regions. After sliding, the complete recrystallization of the substructure takes place at temperature c.a. 600 °C. Some changes in the de…
Machinability of Engineering Materials
2008
Chapter 13 provides comprehensive knowledge regarding machinability of construction materials and characterizes various meanings of this specific material feature, allowing effective selection of machining conditions. Factors affecting machinability and typical causes of low machinability are discussed. Three groups of machinability criteria are selected, including basic, substitutive and auxiliary ones. In particular, the cutting speed corresponding to economic or high productivity criteria and obtainable surface roughness are distinguished as basic machinability criteria. Relative and absolute machining rating systems are highlighted, and appropriate material groups and values of the mach…
Influence of machining conditions on friction in metal cutting process – A review
2019
This paper presents a range of variable machining factors which influence substantially friction directly or by the tool wear developed in the cutting zone. The group of direct factors include the workpiece and cutting tool materials coupled, the cutting/sliding velocity, cooling media supplied to the tool-chip contact zone, modification of the tool contact faces by micro-texturing. Special attention was paid to the tool wear evolution and its pronounced effect on changes of the contact conditions.
A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries
2018
© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…