Search results for " X-Ray Computed"
showing 4 items of 784 documents
A new tool to improve pedicle screw placement accuracy in navigated spine surgery: A monocentric study
2021
Objective Navigated instrumented spine surgery is burden by a low but significant screw mispositioning risks, respectively, for the 2D imaging system from 15 to 40% and, for the 3D imaging system, ranging from 4.1 to 11.5%. The primary objective of this study was to demonstrate the efficacy of a new "screw-like" tool in order to further decrease pedicle screws mispositioning rate during vertebral navigated spine surgery. Materials and methods Between January and June 2019 an initial case series of 18 patients were enrolled. All patients underwent a pedicle screw fixation, both in thoracic (Th10-Th12) and lumbosacral (L1-S1) spine, using O-arm (Medtronic Navigation, Louisville, Colorado) and…
Impaired geometric properties of tibia in older women with hip fracture history.
2007
This study evaluated side-to-side differences in tibial mineral mass and geometry in women with previous hip fracture sustained on average 3.5 years earlier. Both tibial mineral mass and geometry were found to be reduced in the fractured leg. INTRODUCTION: The purpose of this study was to evaluate side-to-side differences in tibial mineral mass and geometry after hip fracture and to assess the determinants of such differences. METHODS: Thirty-eight 60- to 85-year-old women with a previous hip fracture and 22 same-aged control women without fractures participated in the study. Bone characteristics of the distal tibia and tibial shaft of both legs were assessed using pQCT in order to compare …
Patient Specific Instrumentation for Total Knee Arthroplasty: a Literature Review
2014
During the past decade, total knee arthroplasty (TKA) has been markedly increased. Recently, patient-specific custom cutting guides have been commercially introduced in order to achieve an accurate component alignment during TKA. In fact, these cutting blocks are specific to a patient’s knee anatomy and should help the surgeons to perform bone cuts, reducing the complexity of conventional alignment and sizing tools. Nevertheless, there are critical arguments against patient-specific cutting guides for routine use, such as poor evidence and higher costs. Additionally, there are still no mild and long-term results available that describe the clinical outcomes following patient-specific instru…
Role of post mortem computed tomography in diagnosis of upper cervical fractures in child due to road accident: A case report and literature review
2019
The upper cervical spine has unique anatomical features that distinguish it from the remainder of the cervical spine. Its motion segments make up a large amount of total cervical spine motion and, as a result,predispose it to a unique set of injuries. Cervical spine trauma is a common problem with a wide range of severity from minor ligamentous injury to section of the spinal cord. The use of post mortem CT (PMCT), and the subsequent multi-planar and volume rendering reconstruction techniques can provide non-invasive, objective operator-independent imaging data set that may be further reviewed by other specialists. and can substantially add to forensic examinations of the skeleton, especial…