Search results for " aorta"

showing 10 items of 185 documents

CT-Determined Maximum Pulmonary Artery to Ascending Aorta Diameter Ratio in Nonsevere COVID-19 Patients

2021

2019-20 coronavirus outbreakCoronavirus disease 2019 (COVID-19)business.industrySARS-CoV-2Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)COVID-19Pulmonary ArteryDiameter ratioText miningTomography x ray computedRadiology Nuclear Medicine and imagingmedicine.arteryPulmonary arteryAscending aortaMedicineHumansRadiology Nuclear Medicine and imagingbusinessNuclear medicineLetters to the EditorTomography X-Ray ComputedAortaAcademic Radiology
researchProduct

Periscopes, chimneys, sandwich and VORTEC to facilitate abdominal and thoracoabdominal aortic aneurysm repair

2012

The VORTEC (VIABAHN open revascularization technique) and the chimney graft technique are tools with which to maintain or restore blood flow to the aortic branches and can be used intentionally or as a bailout procedure in open surgery or endovascular procedures. VORTEC is a stent graft-based vascular connection technique that achieves end-to-end anastomosis configuration; it is especially useful when the traditional suture technique proves (can be) cumbersome. It is also a speedy tool with virtually no blood flow interruption and no anastomotic bleeding, and patency rates compare favorably with sutured anastomosis. The chimney/periscope, as well as the sandwich graft technique (CHIMPES), i…

Abdominal aorta Thoracic aorta Aortic aneurysm Blood vessel prosthesis Endovascular procedures
researchProduct

Effect of aneurysm on the mechanical dissection properties of the human ascending thoracic aorta

2012

Objectives: The acute dissection of an ascending thoracic aortic aneurysm (ATAA) represents a devastating separation of elastic layers occurring when the hemodynamic loads on the diseased wall exceed the adhesive strength between layers. At present, the mechanics underlying aortic dissection are largely unclear, and the biomechanical delamination properties of the aneurysmal aorta are not defined. Individuals with bicuspid aortic valve (BAV) are particularly predisposed to ascending aortic aneurysm formation, with a marked risk of aortic dissection. The purpose of this study was to evaluate and compare the dissection properties of nonaneurysmal and aneurysmal human ascending thoracic aorta …

AdultHeart Defects CongenitalMaleAortic valvePulmonary and Respiratory Medicinemedicine.medical_specialtyAorta ThoracicDissection (medical)Risk AssessmentThoracic aortic aneurysmArticleAortic aneurysmBicuspid aortic valveRisk FactorsAneurysm DissectingTensile StrengthInternal medicinemedicine.arterymedicineHumansThoracic aortaAgedAortic dissectionAnalysis of VarianceAortaAortic Aneurysm Thoracicbusiness.industryRisk FactorHemodynamicsSettore ING-IND/34 - Bioingegneria IndustrialeAnatomyMiddle AgedPennsylvaniamedicine.diseaseBiomechanical PhenomenaAortic Dissectionmedicine.anatomical_structureAortic ValveMicroscopy Electron Scanningcardiovascular systemCardiologyFemaleSurgerybusinessCardiology and Cardiovascular MedicineHumanThe Journal of Thoracic and Cardiovascular Surgery
researchProduct

Double inlet left ventricular main chamber, subaortic small left sided right ventricle and interrupted aortic arch type A. What operation is indicate…

1987

A case of a 23 year old female patient who suffered from the complex congenital heart lesion of a double inlet left ventricular main chamber, subaortic small left sided right ventricle and interrupted aortic arch type A is reported. With equally high blood pressures, the perfusion in the upper half of the body was maintained through the ascending aorta while the lower half and the lungs were supplied through the pulmonary artery and a patent ductus arteriosus (PDA). Angiographically, the bulbo-ventricular foramen appeared to be nonrestrictive. However, distinct signs of muscular subaortic stenosis were detected. The hemodynamic status principally allowed surgical correction when this became…

AdultHeart Defects CongenitalPulmonary and Respiratory MedicineAortic archmedicine.medical_specialtyHeart VentriclesAorta ThoracicAfterloadInternal medicinemedicine.arteryDuctus arteriosusAscending aortaMethodsmedicineHumansAortabusiness.industryPalliative CareInterrupted aortic arch type Amedicine.anatomical_structureDescending aortaPulmonary arterycardiovascular systemCardiologyFemaleSurgeryCardiology and Cardiovascular MedicinebusinessThe Thoracic and Cardiovascular Surgeon
researchProduct

Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair

2015

Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TE…

AdultMaleAortic archmedicine.medical_specialtyHemodynamicsAorta ThoracicHealth InformaticsProsthesis DesignBlood Vessel Prosthesis ImplantationYoung AdultAortic aneurysmBlood vessel prosthesismedicine.arteryInternal medicineFluid-structure interactionStentHumansMedicineThoracic aortaStent-graftHemodynamicEndovascular ProcedureAortaAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresHemodynamicsmedicine.diseaseCurvatures of the stomachBlood Vessel ProsthesisComputer Science ApplicationsSurgeryAlgorithmRadiographyDescending aortaCalibrationCardiologyEndograft collapse/infoldingStentsStress MechanicalThoracic endovascular aortic repair (TEVAR)businessAlgorithmsBird-beakHumanComputers in Biology and Medicine
researchProduct

Medial tunica degeneration of the ascending aortic wall is associated with specific microRNA changes in bicuspid aortic valve disease

2021

Ascending aortic diameter is not an accurate parameter for surgical indication in patients with bicuspid aortic valve (BAV). Thus, the present study aimed to identify specific microRNAs (miRNAs/miRs) and their expression levels in aortic wall aneurysm associated with BAV according to severity of medial degeneration and to elucidate the association between the tissue expression levels of the miRNAs with their expression in plasma. Aortic wall and blood specimens were obtained from 38 patients: 12 controls and 26 patients with BAV with ascending aortic aneurysm. Of the patients with BAV, 19 had cusp fusions of right and left, 5 of right and non-coronary, and 2 of left and non-coronary. Two gr…

AdultMaleCancer ResearchPathologymedicine.medical_specialtyascending aortaGene ExpressionDissection (medical)BiochemistryAortic aneurysmBicuspid aortic valveAneurysmBicuspid Aortic Valve Diseasemedicine.arteryAscending aortaGeneticsHumansMedicineMolecular BiologyAortaAgedbicuspid aortic valve disease microRNAs ascending aorta biomarkersOncogeneSettore BIO/16 - Anatomia Umanabusiness.industrybiomarkersArticlesMiddle Agedmedicine.diseaseMolecular medicinemicroRNAsAortic AneurysmSettore MED/23ItalyOncologyAortic ValveMolecular MedicineBiomarker (medicine)FemaleTranscriptomebusinessMolecular Medicine Reports
researchProduct

Enormous hemangiosarcoma of the heart

1994

This report describes a 26-year-old patient with hemangiosarcoma of the heart and summarizes the clinicopathological features in previous reports of patients with cardiac angiosarcoma. The patient was admitted to our hospital because of a syncope and one episode of nocturnal dyspnea and hemoptysis. In his history he complained of progressive weakness and loss of weight over the past 2 months. Echocardiography and computed tomography of the chest showed inhomogeneous masses in the pericardial cavity completely surrounding the heart and involving the ascending aorta and the superior vena cava. Histological examination of the tissue obtained from the mass by fine needle technique revealed a po…

AdultMaleHemoptysismedicine.medical_specialtyLung NeoplasmsHeart diseaseRadiographyHemangiosarcomaShock CardiogenicSyncopeHeart NeoplasmsFatal OutcomeSuperior vena cavamedicine.arteryDrug DiscoveryAscending aortaHumansMedicineAngiosarcomaGenetics (clinical)business.industryVascular diseasePalliative CarePericardial cavityGeneral Medicinemedicine.diseaseSurgeryHemangiosarcomaEchocardiographyMolecular MedicineRadiologybusinessThe Clinical Investigator
researchProduct

Shear Stress and Aortic Strain Associations With Biomarkers of Ascending Thoracic Aortic Aneurysm

2019

This study aims to investigate the association of wall shear stress (WSS) and aortic strain with circulating biomarkers including matrix metalloproteinases (MMP), tissue inhibitors of metalloproteinase (TIMP), and exosomal level of microRNA (miRNA) in ascending aortic aneurysms of patients with bicuspid or tricuspid aortic valve.A total of 76 variables from 125 patients with ascending aortic aneurysms were collected from (1) blood plasma to measure plasma levels of miRNAs and protein activity; (2) computational flow analysis to estimate peak systolic WSS and time-average WSS (TAWSS); and (3) imaging analysis of computed tomography angiography to determine aortic wall strain. Principal compo…

AdultMalePulmonary and Respiratory MedicineAortic valvemedicine.medical_specialtybicuspid aortic valveVascular Remodeling030204 cardiovascular system & hematologyMechanotransduction CellularThoracic aortic aneurysm03 medical and health sciencesAortic aneurysm0302 clinical medicineBicuspid aortic valveBicuspid Aortic Valve Diseaseascending thoracic aortic aneurysmMatrix Metalloproteinase 12medicine.arteryInternal medicineAscending aortamedicineHumansAortaAgedComputed tomography angiographyAortaTissue Inhibitor of Metalloproteinase-1Aortic Aneurysm Thoracicmedicine.diagnostic_testbusiness.industrybiomarkersSettore ING-IND/34 - Bioingegneria IndustrialeMiddle Agedmedicine.diseaseMicroRNAsLogistic ModelsBlood pressuremedicine.anatomical_structure030228 respiratory systemAortic Valvecardiovascular systemCardiologyFemaleSurgeryStress MechanicalMatrix Metalloproteinase 1Cardiology and Cardiovascular MedicinebusinessThe Annals of Thoracic Surgery
researchProduct

Influence of age and sex on aortic distensibility assessed by MRI in healthy subjects

2010

International audience; Abstract: Magnetic resonance imaging (MRI) is particularly well adapted to the evaluation of aortic distensibility. The calculation of this parameter, based on the change in vessel cross-sectional area per unit change in blood pressure, requires precise delineation of the aortic wall on a series of cine-MR images. Firstly, the study consisted in validating a new automatic method to assess aortic elasticity. Secondly, aortic distensibility was studied for the ascending and descending thoracic aortas in 26 healthy subjects. Two homogeneous groups were available to evaluate the influence of sex and age (with an age limit value of 35 years). The automatic postprocessing …

AdultMalemedicine.medical_specialtyAgingPopulationBiomedical EngineeringBiophysics030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSex FactorsAutomatic processingmedicine.arteryInternal medicineElastic ModulusAscending aortaImage Interpretation Computer-Assistedmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansRadiology Nuclear Medicine and imagingHealthy subjectseducationAortaAortaeducation.field_of_studymedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryMagnetic resonance imagingMagnetic Resonance ImagingElasticityBlood pressureDescending aortaCirculatory systemCardiologycardiovascular systemElasticity Imaging TechniquesAortic stiffnessFemaleRadiologybusinessMRI
researchProduct

Ambulatory follow-up of aortic dissection by transesophageal two-dimensional and color-coded Doppler echocardiography.

1989

Follow-up of 18 patients with aortic dissection (five with type I, one with type II, 11 with type III dissection according to DeBakey) by transesophageal, two-dimensional and color-coded Doppler echocardiography showed a persistence of the false lumen in five of seven patients (71%) after surgery and in nine of 11 patients (82%) after medical therapy. In two patients treated with surgery, the dissected part of the aorta had been resected, whereas in two patients treated medically, a progressive and complete obliteration of the false lumen was observed. In the false lumen, thrombus formation was absent in four, localized in four, and progressive in six patients. Flow within the false lumen c…

AdultMalemedicine.medical_specialtyDissection (medical)Doppler echocardiographyPostoperative ComplicationsAneurysmPhysiology (medical)medicine.arteryAmbulatory CaremedicineHumansThoracic aortaThrombusAortaAgedAortic dissectionAortamedicine.diagnostic_testbusiness.industryMiddle Agedmedicine.diseaseEchocardiography DopplerAortic AneurysmAortic DissectionEchocardiographyRegional Blood FlowDescending aortaFemaleRadiologyCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesCirculation
researchProduct