Search results for " aortic"
showing 10 items of 302 documents
Endovascular versus open surgical repair of abdominal aortic aneurysm with concomitant malignancy
2007
Background The management of patients with abdominal aortic aneurysm (AAA) and concurrent malignancy is controversial. This study retrospectively assessed the outcome of endovascular repair (EVAR) and open repair (OR) for the treatment of AAA in patients undergoing curative treatment for concomitant malignancies. Methods All patients who underwent surgery for a nonruptured infrarenal AAA of ≥5.5 cm and concomitant malignancy between 1997 and 2005 were retrospectively reviewed. Results Identified were 25 patients (22 men; mean age, 70.3 years) with nonruptured infrarenal AAA of ≥5.5 cm (mean size, 6.4 cm) and concomitant malignancy amenable for curative treatment. EVAR was used to treat 11 p…
Early outcomes with a single-sided access endovascular stent
2018
Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …
Initial Clinical Experience Using the Low-Profile Altura Endograft System With Double D-Shaped Proximal Stents for Endovascular Aneurysm Repair.
2018
Purpose: To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double “D-shaped” stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. Methods: From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, an…
Immunoglobulin G4-Related Aortitis and Severe Aortic Valve Stenosis Treated With Transcatheter Aortic Valve Replacement and Immunosuppression.
2021
Abstract IgG4-related disease is an immune-mediated fibro-inflammatory disorder with multisystemic involvement. Aortitis and peri-aortitis are the most common cardiovascular manifestations of the disease. We present the case of a 65-year-old man with symptomatic severe aortic stenosis and concomitant IgG4 aortitis. The diagnosis was confirmed by IgG4 serum levels, positive positron emission computed tomography (PET-CT) scans, and pathology from mediastinal dissection. Surgical aortic valve replacement (SAVR) was unfeasible owing to extensive mediastinal fibrosis, and transcatheter aortic valve replacement (TAVR) was successfully performed. As ascending aorta access for SAVR in IgG4 aortitis…
CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies
2013
PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…
The Gore Hybrid Vascular Graft in renovisceral debranching for complex aortic aneurysm repair.
2016
Objective This study reports our initial experience with the Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) for staged hybrid open renovisceral debranching and endovascular aneurysm repair in patients affected by thoracoabdominal aortic aneurysms and pararenal abdominal aortic aneurysms (PAAAs). Methods Between December 2012 and December 2013, we analyzed outcomes of 13 patients who underwent open surgical debranching of renovisceral vessels for thoracoabdominal aortic aneurysm and PAAAs. All patients were considered at high risk for conventional surgery. Inclusion criterion was treatment by open surgical debranching of at least one visceral artery (renal artery…
Differential Prognostic Value of Galectin-3 According to Carbohydrate Antigen 125 Levels in Transcatheter Aortic Valve Implantation
2019
Galectin-3 (Gal-3) and carbohydrate antigen 125 (CA125) have been associated with adverse outcomes after transcatheter aortic valve implantation (TAVI). Experimental data have suggested a potential molecular interaction. Therefore, we assessed the association of Gal-3 and CA125 with prognosis after TAVI.A total of 439 patients were enrolled. The primary endpoint was a composite of all-cause mortality or readmission for worsening heart failure after TAVI.The primary endpoint occurred in 16.4%. Gal-3 was dichotomized at ≥ 8.71 ng/mL into elevated and not elevated. Gal-3 was elevated in 31.9% and was associated with a higher risk of the primary endpoint (25% vs 12.4%, HR, 2.26; P.001). After m…
Comparison of Carbohydrate Antigen 125 and N-Terminal Pro-Brain Natriuretic Peptide for Risk Prediction After Transcatheter Aortic Valve Implantation
2017
Elevated carbohydrate antigen 125 (CA125) and N-terminal pro-brain natriuretic peptide (NTproBNP) have been associated with adverse outcome after transcatheter aortic valve implantation (TAVI). This study performs a comparison of both biomarkers for prognosis after TAVI. The study includes 363 patients. The primary end point was all-cause death or readmission for worsening congestive heart failure within 1 year after TAVI, and this end point occurred in 16% of the population. The optimal cutoff to predict the primary end point was 18.4 U/ml for CA125 and 2,570 ng/L for NTproBNP. Elevated CA125 levels were present in 52% and were associated with a higher rate of the primary end point (27% vs…
An abdominal aortic aneurysm (AAA) in combination with duplication of the inferior vena cava (IVC), the right renal artery (RRA) and the right renal …
1990
Intra-abdominal abnormality of vessels may sometimes lead to complications. A case of the rare combination of an abdominal aortic aneurysm (AAA) at the origin of the inferior mesenteric a. with duplications of the inferior vena cava (IVC), the right renal a. (RRA) and the right renal v. (RRV) as well as absence of the left common iliac v. is reported.
Acute inferior myocardial infarction due to a large thrombus in the Left coronary sinus of valsalva.
2021
Background Masses in the ascending aorta are an uncommon source of coronary embolism: thrombi located on atherosclerotic aortic plaques are the most frequent cause. A floating thrombus, without evidence of ascending aortic pathology has rarely been reported Method We report a case of an unusual aortic route thromboembolism leading ST segment elevation Myocardial Infarction (STEMI). The patient was referred to the Hub Hospital to undergo urgent coronarography. The examination excluded atherosclerotic coronary arteries disease but an unusual persistence of contrast dye was found at the level of non-coronary sinus. The trans-esophageal echocardiography showed a mobile pedunculated echogenic ma…