Search results for " astigmatism"
showing 10 items of 25 documents
Genome-wide association study for refractive astigmatism reveals genetic co-determination with spherical equivalent refractive error: the CREAM conso…
2015
To identify genetic variants associated with refractive astigmatism in the general population, meta-analyses of genome-wide association studies were performed for: White Europeans aged at least 25 years (20 cohorts, N = 31,968); Asian subjects aged at least 25 years (7 cohorts, N = 9,295); White Europeans aged <25 years (4 cohorts, N = 5,640); and all independent individuals from the above three samples combined with a sample of Chinese subjects aged <25 years (N = 45,931). Participants were classified as cases with refractive astigmatism if the average cylinder power in their two eyes was at least 1.00 diopter and as controls otherwise. Genome-wide association analysis was carried out for …
Anisometropia of spherical equivalent and astigmatism among myopes: a 23-year follow-up study of prevalence and changes from childhood to adulthood.
2017
Purpose To study anisometropia of spherical equivalent and astigmatism from the onset of myopia at school age to adulthood. Methods A total of 240 myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983–1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Examinations with subjective cyclopedic refraction were repeated 3 years later (follow-up 1) for 238 subjects and thereafter at the mean ages of 23.2 (follow-up 2) and 33.9 years (follow-up 3) for 178 and 134 subjects. After exclusions, the 102 subjects who attended all three follow-ups were included in the analyses. Corneal refractive power and astigmatism and anterior cha…
Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism
2017
Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…
Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism
1999
Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…
Refractive Lens Exchange with Foldable Toric Intraocular Lens
2009
To assess visual and refractive outcomes, and rotational stability after refractive lens exchange (RLE) with toric intraocular lens (IOL) implantation to correct ametropia and preexisting astigmatism.Prospective, nonrandomized, observational case series (self-controlled).This prospective, nonrandomized, and self-controlled study included 32 eyes of 19 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having RLE with AcrySof Toric IOL implantation (Alcon Laboratories Inc, Fort Worth, Texas, USA). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), refractive sphere, and keratometric and refractive cylinder were recorded preoperatively …
Astigmatism among myopics and its changes from childhood to adult age: a 23‐year follow‐up study
2014
Purpose To study the prevalence of and changes in astigmatism from the onset of myopia at school age. Methods Two hundred and forty myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983–1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Three annual examinations with subjective cycloplegic refraction were performed for 237–238 subjects. Subsequent examinations were performed at the mean ages of 23.2 and 33.9 years for 178 and 163 subjects, and the last examination, including data from prescriptions of different ophthalmologists, for 32 subjects. Corneal topography was studied at baseline, at the 3-year follow-up and at t…
Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia
2019
PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…
The stenopaeic slit: an analytical expression to quantify its optical effects in front of an astigmatic eye.
2001
The stenopaeic slit is a trial case accessory used in subjective refraction, especially when high astigmatism is present. In spite of its simplicity, the effect of the slit when it is not oriented along one of the principal meridians of the examined eye is difficult to predict, even in terms of classical geometrical optics. In this paper, the optical principles of the slit are considered with full details in the theoretical framework of the dioptric power space. An analytical expression to obtain the residual refractive error when a stenopaeic slit is placed in front of an astigmatic eye at any orientation is deduced. In the light of these results, some aspects of the clinical procedure are…
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism.
2020
Aim To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with low degrees of corneal astigmatism. Methods Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL (FineVision PODFT, PhysIOL s.a., Liege, Belgium) were enrolled. Phacoemulsification with femtosecond laser, capsular tension ring insertion and intraoperative aberrometry were performed in all cases. All IOLs used showed a cylinder power of 1.00 D. Main outcome measures were refractive error and corrected-distance visual acuity (CDVA) and uncorrected-distance visual acuity (UDVA) values. Eyes were evaluated at 4mo post-su…
Visual acuity with computer simulated and lens-induced astigmatism
2014
[EN] The relationship between spherical and astigmatic refractive errors and their associated visual acuity is investigated in this work by means of two different approaches. In the first one, different refractive errors were induced in normal subjects by trial lenses. In the second one, defocused images were simulated numerically by the optical transfer function of a model eye and then judged by the same subjects. The amount of defocus (measured in terms of the modulus of the dioptric power vector) necessary to reduce the visual acuity to 0.1 logMAR and to 0.4 logMAR was computed with each method and then compared. We found that the visual system is clearly more tolerant to lens-induced de…