Search results for " beam"
showing 10 items of 1274 documents
Cylindrical Cuvette Light Refraction Measurements Technology to Analyse Biomedical Liquids
2015
Compact device of high sensitivity for measurement of the refractive indices for both stationary and flowing liquids has been developed. This device can be used to analyse a variety of biomedical liquids: urine, serum protein. The refractive index (RI) is determined by measuring the deviation of a laser beam passing through a cylindrical cuvette containing the test liquid. In order to significantly improve the resolution and stability of RI measurements, the repeated reflections and refractions of the light beam travelling through the cylindrical cuvette are employed.
Hamiltonian tools for the analysis of optical polarization control
2011
Import JabRef; International audience; The study of the polarization dynamics of two counterpropagating beams in optical fibers has recently been the subject of a growing renewed interest, from both the theoretical and experimental points of view. This system exhibits a phenomenon of polarization attraction, which can be used to achieve a complete polarization of an initially unpolarized signal beam, almost without any loss of energy. Along the same way, an arbitrary polarization state of the signal beam can be controlled and converted into any other desired state of polarization, by adjusting the polarization state of the counterpropagating pump beam. These properties have been demonstrate…
Design, construction and cooling system performance of a prototype cryogenic stopping cell for the Super-FRS at FAIR
2015
A cryogenic stopping cell for stopping energetic radioactive ions and extracting them as a low energy beam was developed. This first ever cryogenically operated stopping cell serves as prototype device for the Low-Energy Branch of the Super-FRS at FAIR. The cell has a stopping volume that is 1 m long and 25 cm in diameter. Ions are guided by a DC field along the length of the stopping cell and by a combined RF and DC fields provided by an RE carpet at the exit-hole side. The ultra-high purity of the stopping gas required for optimum ion survival is reached by cryogenic operation. The design considerations and construction of the cryogenic stopping cell, as well as some performance character…
Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation
2012
Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…
Measurement of gap between abutment and fixture in dental conical connection implants. A focused ion beam SEM observation
2020
Background The aim of the authors was to examine the abutment-fixture interface in Morse-type conical implants in order to verify gaps at this level using a new microscopical approach. Material and Methods In this in vitro study, 20 abutment-fixture complexes were prepared by sectioning (longitudinal and cross-sectional to the long axis) with a microtome and then with a focused ion beam (FIB). This is a micrometric machine tool that uses gallium ions to abrade circumscribed areas to dig deeper into the cuts obtained with the microtome in order to eliminate cut-induced artifacts. This is because the FIB abrasion is practically free from artifacts, which are normally generated by the action o…
Validity and reliability of the Turkish version of the orthognathic quality of life questionnaire in patients with dentofacial deformity
2021
Due to the lack of a specific quality of life (QoL) survey on dentofacial deformities (DFD) for Turkish speakers, the present research aimed to perform a translation of the English version of the Orthognathic Quality of Life Questionnaire (OQLQ) into Turkish (the OQLQ-TR) and provide cultural adaptation to the Turkish population. The process of this cross-cultural adaptation followed the six stages given in the guidelines that were proposed by Beaton et al. (2000), which comprised the following: 1) performing the initial translation, 2) synthesizing the translation, 3) performing the back translation, 4) presenting it to the expert committee, and 5) testing the prefinal version. Throughout …
High spatial resolution analysis of the iron oxidation state in silicate glasses using the electron probe
2018
The iron oxidation state in silicate melts is important for understanding their physical properties, although it is most often used to estimate the oxygen fugacity of magmatic systems. Often high spatial resolution analyses are required, yet the available techniques, such as μrXANES and μMössbauer, require synchrotron access. The flank method is an electron probe technique with the potential to measure Fe oxidation state at high spatial resolution but requires careful method development to reduce errors related to sample damage, especially for hydrous glasses. The intensity ratios derived from measurements on the flanks of FeLα and FeLβ X-rays (FeLβf/FeLαf) over a time interval (time-depend…
Coronary artery anomalies: incidence, pathophysiology, clinical relevance and role of diagnostic imaging
2006
Conventional coronary angiography is the gold standard for the diagnosis of coronary artery anomalies. Coronary anomalies are relatively rare findings in patients undergoing conventional coronary angiography for suspected obstructive coronary artery disease. Recently, the increasing performance of diagnostic techniques, such as electron beam tomography (EBT), magnetic resonance (MR) and, more recently, multislice computed tomography (MSCT), has enabled their application to cardiac imaging. MSCT, in particular, has a prominent role in coronary imaging due to its spatial and temporal resolution and three-dimensional capabilities. We report the incidence and pathophysiology of coronary artery …
1985
Nonlinear optical self diffraction effects for a light beam in a liquid crystalline polymer in its isotropic fluid state was observed. This effect is characterized by the absence of a threshold intensity, a diffraction pattern that does not depend on the polarization of the reading beam relative to that of the writing beam and which cannot be disturbed by transversally applied static electrical fields. This effect is attributed to a thermally induced spatial refractive index modulation. The time constants of the response are of the order of ms.
Mechanism of pulsed electron irradiation of the PLZT X/65/35 ceramics
2005
The comprehensive study of high-current pulsed electron irradiation effect on the structure and lattice dynamics as well as Atomic Force (AFM) and Laser Confocal Scanning microscope (LSCM) surface imaginaries of PLZT 8/65/35 ceramics have been performed. X-ray powder diffraction studies show the transformation of the cubic perovskite Pm-3m (Z = 1) into orthorhombic Pmmm (Z = 1) structure for the sample irradiated by one pulse (dose 6 × 1014 electrons/cm2) and into cubic Pm-3m with increased lattice volume and more ordered structure at irradiating by 10 and 100 pulses (dose 6 × 1015 and 6 × 1016 el/cm2). A consequence, the changes of number, intensity and phonon modes position occur in Raman…