Search results for " beam"
showing 10 items of 1274 documents
Surgical evaluation of panoramic radiography and cone beam computed tomography for therapy planning of bisphosphonate-related osteonecrosis of the ja…
2015
The purpose of this retrospective study was to compare the clinical significance of panoramic radiography (orthopantomography [OPTG]) and cone beam computed tomography (CBCT) for therapy planning of bisphosphonate-related osteonecrosis of the jaw (BRONJ) by surgeons.Using standardized questionnaire, eight maxillofacial surgeons evaluated intraoral photographs of the clinical situation of 14 patients with BRONJ as well as the corresponding radiographic images (OPTG, CBCT). The presence of five typical BRONJ signs (bone-remodeling, periosteal reaction, osteosclerosis, sequestra, and continuity of cortical bone) was evaluated with OPTG and CBCT. The influence of radiologic information on thera…
Gray value measurement for the evaluation of local alveolar bone density around impacted maxillary canine teeth using cone beam computed tomography
2021
Background To investigate whether any relationship between local alveolar bone density and maxillary canine impaction using gray values from cone beam computed tomography. Material and Methods The cone beam computed tomography images of 151 patients were retrospectively evaluated. Maxillary canine was defined as an impacted tooth when root formation was complete and the patient’s age older than 13 or the other side of the maxillary canine has completely erupted. Similarly, complete eruption was defined as the tooth in its expected occlusion and position. Using the cone beam computed tomography software, the region of interest which was 5 mm2 in area, was placed in the trabecular bone on cro…
Impact of rectal distension on prostate CBCT-based positioning assessed with 6 degrees-of-freedom couch
2018
International audience; Introduction: Prostate requires a daily correction of its 3-dimensional position in relation with rectal distension. In this study, we sought to determine whether rectal distension with respect to the rectal behavior might have an impact on prostate translations and/or rotations during prostate image guided radiation therapy using a 6 degrees-of-freedom (DOF) couch.Methods and materials: We reviewed the data from 39 patients with localized prostate cancer treated with protracted external radiation therapy using a 6 DOF couch. Before each fraction, a kilovoltage cone beam computed tomography (kV-CBCT) scan was performed. The automatic fusion algorithm was set to fuse …
Evaluation of demineralized bone and bone transplantsin vitroandin vivowith cone beam computed tomography imaging
2010
The objective of this study was to determine the ability of two flat panel cone beam CT (CBCT) devices to identify demineralized bone and bone transplants in vivo and in vitro.Datasets from patients with autologous bone grafts (n = 9, KaVo 3DeXam (KaVo, Biberach, Germany); n = 38, Accuitomo 40 (Morita, Osaka, Japan)) were retrospectively evaluated. Demineralized and non-demineralized porcine cancellous bone blocks were examined with the two CBCT devices. A SawBone skull (Pacific Research Laboratories, Vashon, WA) was used as a positioning tool for the bone blocks. Descriptive evaluation and image quality assessment were conducted on the KaVo 3DeXam data (voxel size 0.3 mm) using the OsiriX …
High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity
2017
PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…
Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (C…
2017
The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute an…
Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo stu…
2013
Objective To evaluate ultrasound transmission velocity (UTV) for assessment of mechanical bone quality, an ex vivo comparison of different bone types measured with UTV, 2-dimensional (2D) histomorphometry and with 3-dimensional (3D) radiology (cone-beam computerized tomography [CBCT], computerized microtomography [μCT]) was conducted. Study Design Clinical cortical, cancellous, and mixed bone (each n = 6) was measured via UTV (m/s), CBCT (white pixel/black pixel ratio [WP/BP]), μCT (bone volume/total volume [μBV/TV]), and histomorphometry (bone volume/total volume [hBV/TV]). UTV values were correlated with 2D-histomorphometry and 3D-radiologic results. Results For the cortical, cancellous, …
Primary Radical Prostatectomy or Ablative Radiotherapy as Protective Factors for Patients With mCRPC Treated With Radium-223 Dichloride: An Italian M…
2020
Abstract Background We investigated, in a real-life setting, the prognostic relevance of previous primary treatment (radical prostatectomy [RP] or external beam radiotherapy [EBRT]) on overall survival for patients with metastatic castration-resistant prostate cancer (mCRPC) treated with radium-223 (223Ra). Materials and Methods In the present multicenter retrospective study, we enrolled 275 consecutive patients. The demographic and clinical data and mCRPC characteristics were recorded and evaluated at baseline and at the end of treatment or progression. 223Ra was administered according to the current label authorization until disease progression or unacceptable toxicity. We divided the who…
Prediction of Normal Organ Absorbed Doses for [177Lu]Lu-PSMA-617 Using [44Sc]Sc-PSMA-617 Pharmacokinetics in Patients With Metastatic Castration Resi…
2018
In vivo pharmacokinetic analysis of [Sc]Sc-PSMA-617 was used to determine the normal organ-absorbed doses that may result from therapeutic activity of [Lu]Lu-PSMA-617 and to predict the maximum permissible activity of [Lu]Lu-PSMA-617 for patients with metastatic castration-resistant prostate carcinoma. Methods Pharmacokinetics of [Sc]Sc-PSMA-617 was evaluated in 5 patients with metastatic castration-resistant prostate carcinoma using dynamic PET/CT, followed by 3 static PET/CT acquisitions and blood sample collection over 19.5 hours, as well as urine sample collection at 2 time points. Total activity measured in source organs by PET imaging, as well as counts per milliliter measured in bloo…
Sprint Time Differences Between Single- and Dual-Beam Timing Systems
2014
Valid and reliable measures of sprint times are necessary to detect genuine changes in sprinting performance. It is currently difficult for practitioners to assess which timing system meets this demand within the constraints of a proper cost-benefit analysis. The purpose of this investigation was to quantify sprint time differences between single-beam (SB) and dual-beam (DB) timing systems. Single-beam and DB photocells were placed at 0, 20, and 40 m to compare 0-20 and 20-40 m sprint times. To control for the influence of swinging limbs between devices, 2 recreationally active participants cycled as fast as possible through the track 25 times with a 160-cm tube (18 cm diameter) vertically …