Search results for " bioengineering"
showing 10 items of 119 documents
Porosity analysis of MTA and Biodentine cements for use in endodontics by using micro?computed tomography
2018
Background The purpose of this study is to compare the porosity of two repair cements, White ProRoot® MTA and Biodentine®. These samples were analyzed by using micro-computed microtomography. Material and methods Sixteen samples were used in the study that were divided according to the composition of the materials used. White ProRoot® MTA (n = 8) and Biodentine® (n = 8) were the samples prepared according to the manufacturer's instructions. They were placed in silicone molds of 5 ± 0.1mm in height and an internal diameter of 5 ± 0.1mm, 24 hours after its preparation, the samples were scanned through a micro-CT, the porosity results were analyzed statistically by independent "t" tests. Resul…
Comparative evaluation of bioactive cements on biomimetic remineralization of dentin
2020
Background This study was designed to quantitatively compare the presence of apatite peaks on demineralized dentin to induced bio-mimetically by bioactive commercial materials. Material and methods Dentin slice specimens (n=6) were prepared and demineralized by by17% EDTA for 2 hours. Each disks materials (Theracal, Biodentine, CPP-ACP) were freshly prepared and was maintained in close contact with a demineralized dentin specimen immersed in PBS solution during one week. To evaluation of bioactivity, cements disks (n=6) were prepared from each material and immersed in PBS solution for one week. The bioactivity and remineralization ability was evaluated using FTIR spectroscopy and Scanning E…
Angular Trapping of Anisometric Nano-Objects in a Fluid
2012
We demonstrate the ability to trap, levitate, and orient single anisometric nanoscale objects with high angular precision in a fluid. An electrostatic fluidic trap confines a spherical object at a spatial location defined by the minimum of the electrostatic system free energy. For an anisometric object and a potential well lacking angular symmetry, the system free energy can further strongly depend on the object's orientation in the trap. Engineering the morphology of the trap thus enables precise spatial and angular confinement of a single levitating nano-object, and the process can be massively parallelized. Since the physics of the trap depends strongly on the surface charge of the objec…
Evaluation of the antibacterial power and biocompatibility of zinc oxide nanorods decorated graphene nanoplatelets: New perspectives for antibiodeter…
2017
Background Nanotechnologies are currently revolutionizing the world around us, improving the quality of our lives thanks to a multitude of applications in several areas including the environmental preservation, with the biodeterioration phenomenon representing one of the major concerns. Results In this study, an innovative nanomaterial consisting of graphene nanoplatelets decorated by zinc oxide nanorods (ZNGs) was tested for the ability to inhibit two different pathogens belonging to bacterial genera frequently associated with nosocomial infections as well as biodeterioration phenomenon: the Gram-positive Staphylococcus aureus and the Gram-negative Pseudomonas aeruginosa. A time- and dose-…
Nanodesign of new self-assembling core-shell gellan-transfersomes loading baicalin and in vivo evaluation of repair response in skin
2017
Gellan nanohydrogel and phospholipid vesicles were combined to incorporate baicalin in new self-assembling core-shell gellan-transfersomes obtained by an easy, scalable method. The vesicles were small in size (~107 nm) and monodispersed (P.I. ≤ 0.24), forming a viscous system (~24 mPa/s) as compared to transfersomes (~1.6 mPa/s), as confirmed by rheological studies. Gellan was anchored to the bilayer domains through cholesterol, and the polymer chains were distributed onto the outer surface of the bilayer, thus forming a core-shell structure, as suggested by SAXS analyses. The optimal carrier ability of core-shell gellan-transfersomes was established by the high deposition of baicalin in th…
Histologic and histomorphometric assessment of eggshell-derived bone graft substitutes on bone healing in rats
2013
Objective: The objective of this study was to histologically and histomorphometrically evaluate the efficacy of the new formulations of eggshell-derived calcium carbonate in rats. Study Design: The study was conducted on 30 adult male rats. Four standardized and circular intrabony defects were created in the both maxilla and mandibula of each animal. Three different graft materials were prepared as follows: 1) Material A: Eggshell-derived calcium carbonate combined with carrageenan gel, 2) Material B: Eggshell-derived calcium carbonate combined with xanthan gum gel, and 3) Material C: Eggshell-derived calcium carbonate powder. The right mandibular defect sites were grafted with Material A i…
A new 3D method for measuring cranio-facial relationships with cone beam computed tomography (CBCT)
2013
Objectives: CBCT systems, with their high precision 3D reconstructions, 1:1 images and accuracy in locating cephalometric landmarks, allows us to evaluate measurements from craniofacial structures, so enabling us to replace the anthropometric methods or bidimensional methods used until now. The aims are to analyse cranio-facial relationships in a sample of patients who had previously undergone a CBCT and create a new 3D cephalometric method for assessing and measuring patients. Study Design: 90 patients who had a CBCT (i-Cat®) as a diagnostic register were selected. 12 cephalometric landmarks on the three spatial planes (X,Y,Z) were defined and 21 linear measurements were established. Using…
Study between anb angle and Wits appraisal in cone beam computed tomography (CBCT)
2013
Objectives: To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. Study Design: Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry included 3 planes of reference, 3 angle measurements and 1 linear measurement. The means and standard deviations of the mean of each measurement were assessed. After that, a Pearson´s correlation coefficient has been performed to analyse the significance of each relationship. Results: When classifying t…
Three-year clinical performance of two indirect composite inlays compared to direct composite restorations
2013
Objective: Despite the incremental build-up of resin composite restorations, their polymerization shrinkage during curing presents a serious problem. Indirect composite resin systems represent an alternative in overcoming some of the deficiencies of direct composite restorations. The hypothesis of the present study states that the clinical performance of restorations may be affected by different generation and application techniques. Study Design: Sixty restorations (20 DI system (Coltene/Whaledent AG, Altstatten, Switzerland) composite inlays, 20 Tescera ATL system (BISCO Inc. Schaumburg, Illinois, USA) composite inlays, and 20 direct composites) were applied to premolar teeth in 49 patien…
In vitro assessment of a novel additive manufactured titanium implant abutment
2021
Background Dental implant temporization remains a clinical challenge. A novel abutment simplifying the procedure was developed, but conventional fabrication was costly and unpredictable. A workflow was developed to fabricate the novel abutment using additive manufacturing. This in vitro investigation assessed the additive manufactured (AM) novel abutments to conventionally manufactured (CM) abutments. Material and methods The AM abutments were fabricated in dental-grade titanium (Ti-6Al-4V) using Selective Laser Melting and were post-processed. The CM abutments were milled and subsequently laser welded manually. Pin strength of the abutments was assessed using a universal loading machine. T…