Search results for " cable"
showing 10 items of 69 documents
Power-Line Communication in Medium-Voltage System: Simulation Model and Onfield Experimental Tests
2012
The aim of this paper is to develop a complete model of a power-line communication (PLC) system operating on a medium-voltage (MV) network. The core-shield configuration was chosen for signal transmission in the power cables. In order to validate the developed model experimental, the medium-voltage network of the Favignana island was used to carry out detailed testing. The transmission was performed between two transformer substations in the presence of mains voltage (i.e., 24 kV). ST7540 FSK power-line transceivers, together with capacitive coupling interfaces, were used for the transmission and the reception of the communication signal. The correlation between the experimental measurement…
SU-FF-T-365: Practical Reconstruction Method for 3D CT-Based Brachytherapy with Shielded Colpostats
2006
Introduction and purpose.‐ The most extended worldwide HDR and PDR afterloading machines are from Nucletron, using the Plato Treatment Planning System (TPS) to perform the clinical dosimetry. The Fletcher‐Williamson (FW) vaginal colpostat applicators are widely used with these machines, they are made of a very dense material (densimet‐17) which allows shielding up to 50% of the dose. Almost all the TPS have incorporated the CT‐Based Brachytherapy (BT), in which the CT catheters and applicators reconstruction is based on contiguous CT transverse slices where the user points the catheter position. The problem with these applicators is the production of artefacts that makes the reconstruction …
The effect of the axial heat transfer on space charge accumulation phenomena in HVDC cables
2020
To date, it has been widespread accepted that the presence of space charge within the dielectric of high voltage direct current (HVDC) cables is one of the most relevant issues that limits the growing diffusion of this technology and its use at higher voltages. One of the reasons that leads to the establishment of space charge within the insulation of cables is the temperature dependence of its conductivity. Many researchers have demonstrated that high temperature drop over the insulation layer can lead to the reversal of the electric field profile. In certain conditions, this can over-stress the insulation during polarity reversal (PR) and transient over voltages (TOV) events accelerating …
Improving angle stability by switching shunt reactors in mixed overhead cable lines. An Italian 400 kV case study
2019
Stringent environmental constraints make the construction of new transmission overhead lines more and more difficult. Alternatively, today it is possible to use cable lines for high (HV) and extra-high (EHV) voltage systems. The configuration of the so-called mixed lines can create some problems in the operation of the electrical system, both during steady-state and transient conditions. In particular, the system stability is one of the main concerns when analyzing the dynamic response of power systems. In this paper, the study of angular stability of a system containing a mixed line is presented: a specific control logic applied to the shunt reactors of the mixed line is proposed as improv…
Simulation and laboratory experimental tests of a line to shield medium voltage power line communication system
2011
A complete model of a power-line communication (PLC) system on a medium-voltage (MV) network in the case of a line-shield configuration is presented in this paper. An MV cable model in a line-shield configuration is considered together with the power transformers, the signal coupling networks, and the receiving and transmitting line coupling interface of a ST7540 FSK power-line transceiver. Simulations of the complete model of the system under consideration have been carried out for different line lengths, with and without power transformers and derivation branches. The model is validated by experimental tests performed in the laboratory. The measured results confirm the reliability of the …
Electromagnetic Full-Wave Simulation of Partial Discharge Detection in High Voltage AC Cables
2019
Partial discharge (PD) activity in the insulation system of an electrical equipment can determine the failure of the whole apparatus. PD sensors are widely used in high-voltage electrical systems as the main elements of a detecting system oriented to real time monitoring. Recently, non-invasive sensors have been proposed in industrial applications for cable and other sensitive electrical parts: they are based both on capacitive and on the electromagnetic radiating coupling. In order to assess the real performance of a new sensor produced by a high voltage AC cables manufacturer, the paper proposes electromagnetic fullwave simulation results.
Partial Discharge on-line measures in cable's EPR insulation
2004
In this paper, an experimental study, carried out on an operating MV cable, is presented. The aim is to identify, locate and characterize defects in the cable's EPR (ethylene-propylene copolymer rubber) insulation. Direct partial discharge measurements have been compared to those obtained by high frequency electromagnetic field measures. The latter have been carried out using a sensor which does not require any galvanic connection with the system under test and that performs an intrinsic localization of the defect. Moreover, an analysis of an MV cable junction has been carried out using the same tools.
The influence of time-dependent phenomena in segmental construction of concrete cable-stayed bridges
2011
Construction stages of a cable-stayed bridge are characterized by a sequence in which geometric configuration, restraints and consequently stress and strain patterns vary many times till the final arrangement is achieved. When construction of concrete bridges is made by cantilever method the influence of time-dependent phenomena becomes significant. In this study an evaluation of stay stressing procedures is given by taking into account creep and shrinkage in cantilever construction of concrete cable-stayed bridges. A methodology of stay stressing is proposed with the final target of reaching the desired geometric configuration. Comparison with classical analyses performed by backward metho…
Efficient modeling of a combined overhead cable line for grounding-system analysis
2008
Simple compact models for combined overhead-cable lines supplying a substation are presented as an extension of a previous paper for grounding system analysis. The overhead line section can be equipped with uniform or combined ground wires, whereas the cable line section can consist of coated metal sheathed cables, with/without intermediate grounding, or uncoated metal sheathed cables in continuous contact with the earth. Besides the calculation of the earth current at the faulted substation, the proposed modeling method allows the evaluation of the leakage current at the transition station, where cables are connected to the overhead line, as well as at critical overhead line towers. In thi…
Overcoming synchronization issues in wireless technology Partial Discharge measurement
2016
In this paper, several aspects of the fundamentals of wireless Partial Discharge (PD) measurements are first discussed. Then, the relevance of the problem of voltage synchronization in PD wireless diagnosis is outlined. When portable instruments are used for PD detection, the main issue is the voltage measurement at the site where the PD detection is carried out. When such analysis is carried out over shielded cables, the AC (50/60 Hz) voltage reference signal is not easily detectable, while one of the basic parameters for PD diagnosis, the displacement of the inception voltage of the PD as compared to the reference voltage, is not available. Even if highperformance sensors are readily avai…